Blood pressure-independent neurogenic effect on conductance and resistance vessels: a consideration for cuffless blood pressure measurement?

被引:5
|
作者
Cox, James [1 ]
Avolio, Alberto P. [1 ]
Louka, Kyrollos [1 ]
Shirbani, Fatemeh [1 ]
Tan, Isabella [1 ]
Butlin, Mark [1 ]
机构
[1] Macquarie Univ, Fac Med Hlth & Human Sci, Macquarie Med Sch, Sydney, NSW, Australia
来源
2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC) | 2021年
关键词
cuffless blood pressure; photoplethysmography; tonometry; pulse transit time; pulse arrival time; arterial stiffness; wearable devices; HEART-RATE; DEPENDENCY;
D O I
10.1109/EMBC46164.2021.9629936
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Pulse transit time (PTT) and pulse arrival time (PAT) are promising measures for cuffless arterial blood pressure (BP) estimation given the intrinsic arterial stiffness-BP relationship. However, arterial stiffness (and PTT) is altered by autonomically-driven smooth muscle tension changes, potentially independent of BP. This would limit PTT or PAT as accurate BP correlates, more so in resistance vessels than conductance arteries. Objective: To quantify if there is a measurable neurogenic effect on PAT measured using photoplethysmography (PPG) (path includes resistance vessels) and radial artery tonometry (path includes only conductance vessels) during physiologically induced BP changes. Methods: PATs were measured continuously in participants (n=15, 35 +/- 15 years, 9 male) using an electrocardiogram and, simultaneously, a Finometer (R) PRO finger sensor, a finger PPG sensor and radial artery tonometer during seated rest, cold pressor test, cycling and isometric handgrip (IHG) exercise. Delta BP/Delta PAT was calculated for each sensor and each condition. Results: All interventions significantly increased BP. A significant difference was observed in Delta BP/Delta PAT between cycling and both the cold pressor test and IHG exercise (p<0.05). Delta BP/Delta PAT did not differ whether measured via PPG or tonometry. Conclusions: Under the conditions tested, autonomic function does not have a BP-independent effect on PAT where the path includes resistance vessels (PPG signal), likely due to the speed of the wave and the short path length of resistance vessels. Autonomic function therefore does not limit the ability for use of PPG as a signal for potentially estimating BP without a cuff.
引用
收藏
页码:7485 / 7488
页数:4
相关论文
共 50 条
  • [31] Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm
    Ding, Xiaorong
    Zhang, Yuan-Ting
    BIOMEDICAL ENGINEERING LETTERS, 2019, 9 (01) : 37 - 52
  • [32] Noninvasive Cuffless Estimation of Blood Pressure using Photoplethysmography without Electrocardiograph Measurement
    Samria, Rohan
    Jain, Ridhi
    Jha, Ankita
    Saini, Sandeep
    Chowdhury, Shubhajit Roy
    2014 IEEE REGION 10 SYMPOSIUM, 2014, : 254 - 257
  • [33] Study of cuffless blood pressure estimation method based on multiple physiological parameters
    Zhang, Yiming
    Zhou, Congcong
    Huang, Zhongyi
    Ye, Xuesong
    PHYSIOLOGICAL MEASUREMENT, 2021, 42 (05)
  • [34] Learning and non-learning algorithms for cuffless blood pressure measurement: a review
    Agham, Nishigandha Dnyaneshwar
    Chaskar, Uttam M.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2021, 59 (06) : 1201 - 1222
  • [35] History and evolution of blood pressure measurement
    Noh, Su A.
    Kim, Hwang-Soo
    Kang, Si-Hyuck
    Yoon, Chang-Hwan
    Youn, Tae-Jin
    Chae, In-Ho
    CLINICAL HYPERTENSION, 2024, 30 (01)
  • [36] Dynamic Pulse Wave Velocity Response to Hydrostatic Blood Pressure Gradient: A Pressure-Independent Marker of Vascular Aging?
    Climie, Rachel E.
    Bruno, Rosa-Maria
    AMERICAN JOURNAL OF HYPERTENSION, 2020, 33 (12) : 1075 - 1077
  • [37] The Promise and Illusion of Continuous, Cuffless Blood Pressure Monitoring
    Hu, Jiun-Ruey
    Park, Dae Yong
    Agarwal, Nikita
    Herzig, Matthew
    Ormseth, George
    Kaushik, Milan
    Giao, Duc M.
    Turkson-Ocran, Ruth-Alma N.
    Juraschek, Stephen P.
    CURRENT CARDIOLOGY REPORTS, 2023, 25 (10) : 1139 - 1149
  • [38] Validating cuffless continuous blood pressure monitoring devices
    Hu, Jiun-Ruey
    Martin, Gabrielle
    Iyengar, Sanjna
    Kovell, Lara C.
    Plante, Timothy B.
    van Helmond, Noud
    Dart, Richard A.
    Brady, Tammy M.
    Turkson-Ocran, Ruth-Alma N.
    Juraschek, Stephen P.
    CARDIOVASCULAR DIGITAL HEALTH JOURNAL, 2023, 4 (01): : 9 - 20
  • [39] Estimating Blood Pressure during Exercise with a Cuffless Sphygmomanometer
    Hayashi, Kenta
    Maeda, Yuka
    Yoshimura, Takumi
    Huang, Ming
    Tamura, Toshiyo
    SENSORS, 2023, 23 (17)
  • [40] Cuffless and Touchless Measurement of Blood Pressure from Ballistocardiogram Based on a Body Weight Scale
    Liu, Shing-Hong
    Zhang, Bing-Hao
    Chen, Wenxi
    Su, Chun-Hung
    Chin, Chiun-Li
    NUTRIENTS, 2022, 14 (12)