Blood pressure-independent neurogenic effect on conductance and resistance vessels: a consideration for cuffless blood pressure measurement?

被引:5
|
作者
Cox, James [1 ]
Avolio, Alberto P. [1 ]
Louka, Kyrollos [1 ]
Shirbani, Fatemeh [1 ]
Tan, Isabella [1 ]
Butlin, Mark [1 ]
机构
[1] Macquarie Univ, Fac Med Hlth & Human Sci, Macquarie Med Sch, Sydney, NSW, Australia
来源
2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC) | 2021年
关键词
cuffless blood pressure; photoplethysmography; tonometry; pulse transit time; pulse arrival time; arterial stiffness; wearable devices; HEART-RATE; DEPENDENCY;
D O I
10.1109/EMBC46164.2021.9629936
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Pulse transit time (PTT) and pulse arrival time (PAT) are promising measures for cuffless arterial blood pressure (BP) estimation given the intrinsic arterial stiffness-BP relationship. However, arterial stiffness (and PTT) is altered by autonomically-driven smooth muscle tension changes, potentially independent of BP. This would limit PTT or PAT as accurate BP correlates, more so in resistance vessels than conductance arteries. Objective: To quantify if there is a measurable neurogenic effect on PAT measured using photoplethysmography (PPG) (path includes resistance vessels) and radial artery tonometry (path includes only conductance vessels) during physiologically induced BP changes. Methods: PATs were measured continuously in participants (n=15, 35 +/- 15 years, 9 male) using an electrocardiogram and, simultaneously, a Finometer (R) PRO finger sensor, a finger PPG sensor and radial artery tonometer during seated rest, cold pressor test, cycling and isometric handgrip (IHG) exercise. Delta BP/Delta PAT was calculated for each sensor and each condition. Results: All interventions significantly increased BP. A significant difference was observed in Delta BP/Delta PAT between cycling and both the cold pressor test and IHG exercise (p<0.05). Delta BP/Delta PAT did not differ whether measured via PPG or tonometry. Conclusions: Under the conditions tested, autonomic function does not have a BP-independent effect on PAT where the path includes resistance vessels (PPG signal), likely due to the speed of the wave and the short path length of resistance vessels. Autonomic function therefore does not limit the ability for use of PPG as a signal for potentially estimating BP without a cuff.
引用
收藏
页码:7485 / 7488
页数:4
相关论文
共 50 条
  • [1] Cuffless Blood Pressure Measurement
    Mukkamala, Ramakrishna
    Stergiou, George S.
    Avolio, Alberto P.
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2022, 24 : 203 - 230
  • [2] Cuffless Blood Pressure Devices
    Bradley, Corey K.
    Shimbo, Daichi
    Colburn, David Alexander
    Pugliese, Daniel N.
    Padwal, Raj
    Sia, Samuel K.
    Anstey, D. Edmund
    AMERICAN JOURNAL OF HYPERTENSION, 2022, 35 (05) : 380 - 387
  • [3] A new system for cuffless blood pressure measurement
    Ankishan, H.
    Ari, Fikret
    Celik, Haydar
    Frederick, Blaise B.
    Hocke, Lia M.
    Erdogan, Sinem Burcu
    Unal, Mehmet Altay
    APPLIED ACOUSTICS, 2023, 212
  • [4] Beat-to-beat blood pressure measurement using a cuffless device does not accurately reflect invasive blood pressure
    Moharram, Mohammed A.
    Wilson, Luke C.
    Williams, Michael J. A.
    Coffey, Sean
    INTERNATIONAL JOURNAL CARDIOLOGY HYPERTENSION, 2020, 5
  • [5] Challenges Presented by Cuffless Measurement of Blood Pressure if Adopted for Diagnosis and Treatment of Hypertension
    Avolio, Alberto
    Cox, James
    Louka, Kyrollos
    Shirbani, Fatemeh
    Tan, Isabella
    Qasem, Ahmad
    Butlin, Mark
    PULSE, 2022, 10 (1-4) : 34 - 45
  • [6] Cuffless Blood Pressure Estimation Using Pressure Pulse Wave Signals
    Liu, Zeng-Ding
    Liu, Ji-Kui
    Wen, Bo
    He, Qing-Yun
    Li, Ye
    Miao, Fen
    SENSORS, 2018, 18 (12)
  • [7] Cuffless blood pressure estimation using only a smartphone
    Matsumura, Kenta
    Rolfe, Peter
    Toda, Sogo
    Yamakoshi, Takehiro
    SCIENTIFIC REPORTS, 2018, 8
  • [8] Cuffless Estimation of Blood Pressure: Importance of Variability in Blood Pressure Dependence of Arterial Stiffness Across Individuals and Measurement Sites
    Butlin, Mark
    Shirbani, Fatemeh
    Barin, Edward
    Tan, Isabella
    Spronck, Bart
    Avolio, Alberto P.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (11) : 2377 - 2383
  • [9] State-of-the-Art Analysis of Cuffless Methods for Blood Pressure Measurement
    Burbach, Simon
    Brueck, Rainer
    Keil, Alexander
    ADVANCES IN DIGITAL HEALTH AND MEDICAL BIOENGINEERING, VOL 1, EHB-2023, 2024, 109 : 127 - 134
  • [10] A Comparison of Wearable Tonometry, Photoplethysmography, and Electrocardiography for Cuffless Measurement of Blood Pressure in an Ambulatory Setting
    Mieloszyk, Rebecca
    Twede, Hope
    Lester, Jonathan
    Wander, Jeremiah
    Basu, Sumit
    Cohn, Gabe
    Smith, Greg
    Morris, Dan
    Gupta, Sidhant
    Tan, Desney
    Villar, Nicolas
    Wolf, Moni
    Malladi, Sailaja
    Mickelson, Matt
    Ryan, Lauren
    Kim, Lindsey
    Kepple, Jeffrey
    Kirchner, Susanne
    Wampler, Emma
    Terada, Riena
    Robinson, Joel
    Paulsen, Ron
    Saponas, T. Scott
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (07) : 2864 - 2875