Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: A histologically controlled insertion study

被引:162
作者
Adunka, O
Unkelbach, MH
Mack, M
Hambek, M
Gstoettner, W
Kiefer, J
机构
[1] Goethe Univ Frankfurt, ENT Dept, D-60590 Frankfurt, Germany
[2] Goethe Univ Frankfurt, Dept Radiol, D-60590 Frankfurt, Germany
关键词
cochlear implant; hearing preservation; intracochlear trauma; round window membrane;
D O I
10.1080/00016480410018179
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective-To evaluate cochlear implant trauma to intracochlear structures when inserting the electrode via the round window membrane. Material and Methods-Eight fresh human temporal bones were evaluated histologically after insertion using two types of cochlear implant array. Bones underwent a special fixation and embedding procedure that allowed sectioning of undecalcified bone with the electrode in situ. Insertions depths were evaluated radiologically and histologically. Results-All arrays were found in the scala tympani of the cochlea. Basal trauma could be avoided in all but one specimen. The mean depth of insertion was 382.5degrees. Apically, only one implanted bone showed cochlear trauma exceeding lifting of the basilar membrane. Conclusion-Insertions through the round window membrane were shown to be atraumatic, even in basal cochlear regions. This route of insertion might be very effective for combined electric and acoustic stimulation of the auditory system.
引用
收藏
页码:807 / 812
页数:6
相关论文
共 25 条
  • [1] Ars B, 1996, AM J OTOL, V17, P40
  • [2] BANFAI P, 1978, HNO, V26, P85
  • [3] PRESERVATION OF COCHLEAR FUNCTION AFTER EXTENSIVE LABYRINTHINE DESTRUCTION
    BUMSTED, RM
    DOLAN, KD
    SADE, J
    MCCABE, BF
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1977, 86 (02) : 131 - 137
  • [4] CANALIS RF, 1987, LARYNGOSCOPE, V97, P575
  • [5] CLARK GM, 1984, ACTA OTO-LARYNGOL, P5
  • [6] Comparative study of cochlear damage with three perimodiolar electrode designs
    Eshraghi, AA
    Yang, NW
    Balkany, TJ
    [J]. LARYNGOSCOPE, 2003, 113 (03) : 415 - 419
  • [7] The Clarion electrode positioner: Temporal bone studies
    Fayad, JN
    Luxford, W
    Linthicum, FH
    [J]. AMERICAN JOURNAL OF OTOLOGY, 2000, 21 (02) : 226 - 229
  • [8] SURGICAL ANATOMY OF THE ROUND WINDOW WITH SPECIAL REFERENCE TO COCHLEAR IMPLANTATION
    FRANZ, BKH
    CLARK, GM
    BLOOM, DM
    [J]. JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1987, 101 (02) : 97 - 102
  • [9] GOYCOOLEA MV, 1987, LARYNGOSCOPE, V97, P766
  • [10] Cochlear implant deep electrode insertion: Extent of insertional trauma
    Gstoettner, W
    Plenk, H
    Franz, P
    Hamzavi, J
    Baumgartner, W
    Czerny, C
    Ehrenberger, K
    [J]. ACTA OTO-LARYNGOLOGICA, 1997, 117 (02) : 274 - 277