Forward-viewing resonant fiber-optic scanning endoscope of appropriate scanning speed for 3D OCT imaging

被引:76
作者
Huo, Li [1 ]
Xi, Jiefeng [1 ]
Wu, Yicong [1 ]
Li, Xingde [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
OPTICAL COHERENCE TOMOGRAPHY; MIRROR;
D O I
10.1364/OE.18.014375
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A forward-viewing resonant fiber-optic endoscope of a scanning speed appropriate for a high-speed Fourier-domain optical coherence tomography (FD-OCT) system was developed to enable real-time, three-dimensional endoscopic OCT imaging. A new method was explored to conveniently tune the scanning frequency of a resonant fiber-optic scanner, by properly selecting the fiber-optic cantilever length, partially changing the mechanical property of the cantilever, and adding a weight to the cantilever tip. Systematic analyses indicated the resonant scanning frequency can be tuned over two orders of magnitude spanning from similar to 10Hz to similar to kHz. Such a flexible scanning frequency range makes it possible to set an appropriate scanning speed of the endoscope to match the different A-scan rates of a variety of FD-OCT systems. A 2.4-mm diameter, 62.5-Hz scanning endoscope appropriate to work with a 40-kHz swept-source OCT (SS-OCT) system was developed and demonstrated for 3D OCT imaging of biological tissues. (C) 2010 Optical Society of America
引用
收藏
页码:14375 / 14384
页数:10
相关论文
共 18 条
[1]   Optical coherence tomography using a frequency-tunable optical source [J].
Chinn, SR ;
Swanson, EA ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (05) :340-342
[2]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[3]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[4]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[5]   Buffered Fourier domain mode locking: unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s [J].
Huber, Robert ;
Adler, Desmond C. ;
Fujimoto, James G. .
OPTICS LETTERS, 2006, 31 (20) :2975-2977
[6]  
Kinsler L.. E., 2000, FUNDAMENTALS ACOUSTI
[7]  
Kuznetsov M., 2010, P SPIE, V7554
[8]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[9]   Imaging needle for optical coherence tomography [J].
Li, XD ;
Chudoba, C ;
Ko, T ;
Pitris, C ;
Fujimoto, JG .
OPTICS LETTERS, 2000, 25 (20) :1520-1522
[10]   Rapid-scanning forward-imaging miniature endoscope for real-time optical coherence tomography [J].
Liu, XM ;
Cobb, MJ ;
Chen, YC ;
Kimmey, MB ;
Li, XD .
OPTICS LETTERS, 2004, 29 (15) :1763-1765