UK national survey of enucleation, evisceration and orbital implant trends

被引:67
作者
Viswanathan, P.
Sagoo, Mandeep S.
Olver, Jane M.
机构
[1] Western Eye Hosp, Oculoplast & Orbital Serv, London NW1 5YE, England
[2] Moorfields Eye Hosp, London, England
[3] Watford Dist Gen Hosp, Dept Ophthalmol, Watford, England
关键词
D O I
10.1136/bjo.2006.103937
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To evaluate current clinical practice in the UK in the management of the anophthalmic socket; choice of enucleation, evisceration, type of orbital implant, wrap, motility pegging and complications. Methods: All consultant ophthalmologists in the UK were surveyed by postal questionnaire. Questions included their practice subspecialty and number of enucleations and eviscerations performed in 2003. Specific questions addressed choice of implant, wrap, motility pegging and complications. Results: 456/896 (51%) consultants responded, of which 162 (35%) had a specific interest in oculoplastics, lacrimal, orbits or oncology. Only 243/456 (53%) did enucleations or eviscerations. 92% inserted an orbital implant after primary enucleation, 69% after non-endophthalmitis evisceration, whereas only 43% did so after evisceration for endophthalmitis (50% as a delayed procedure). 55% used porous orbital implants (porous polyethylene, hydroxyapatite or alumina) as their first choice and 42% used acrylic. Most implants inserted were spherical, sized 18-20 mm in diameter. 57% wrapped the implant after enucleation, using salvaged autogenous sclera (20%), donor sclera (28%) and synthetic Vicryl or Mersilene mesh (42%). A minority (7%) placed motility pegs in selected cases, usually as a secondary procedure. 14% of respondents reported implant exposure for each type of procedure and extrusion was reported by 4% after enucleation and 3% after evisceration. Conclusions: This survey highlights contemporary anophthalmic socket practice in the UK. Most surgeons use porous orbital implants with a synthetic wrap after enucleation and only few perform motility pegging.
引用
收藏
页码:616 / 619
页数:4
相关论文
共 17 条
  • [1] AFRAN SI, 1987, OPHTHALMOLOGY, V94, P235
  • [2] 32 CASES OF SYMPATHETIC OPHTHALMIA - A RETROSPECTIVE STUDY AT THE NATIONAL-EYE-INSTITUTE, BETHESDA, MD, FROM 1982 TO 1992
    CHAN, CC
    ROBERGE, FG
    WHITCUP, SM
    NUSSENBLATT, RB
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (05) : 597 - 600
  • [3] Comparison of artificial eye amplitudes with acrylic and hydroxyapatite spherical enucleation implants
    Colen, TP
    Paridaens, DA
    Lemij, HG
    Mourits, MP
    van den Bosch, WA
    [J]. OPHTHALMOLOGY, 2000, 107 (10) : 1889 - 1894
  • [4] Comparative motility of hydroxyapatite and alloplastic enucleation implants
    Custer, PL
    Trinkaus, KM
    Fornoff, J
    [J]. OPHTHALMOLOGY, 1999, 106 (03) : 513 - 516
  • [5] Orbital implants in enucleation surgery - A report by the American Academy of Ophthalmology
    Custer, PL
    Kennedy, RH
    Woog, JJ
    Kaltreider, SA
    Meyer, DR
    [J]. OPHTHALMOLOGY, 2003, 110 (10) : 2054 - 2061
  • [6] Primary implant placement with evisceration in patients with endophthalmitis
    Dresner, SC
    Karesh, JW
    [J]. OPHTHALMOLOGY, 2000, 107 (09) : 1661 - 1664
  • [7] Sympathetic ophthalmia following evisceration: A rare case
    Griepentrog, GJ
    Lucarelli, MJ
    Albert, DM
    Nork, TM
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2005, 21 (04) : 316 - 318
  • [8] Incidence of sympathetic ophthalmia after penetrating eye injury and choice of treatment
    Gürdal, C
    Erdener, U
    Irkeç, M
    Orhan, M
    [J]. OCULAR IMMUNOLOGY AND INFLAMMATION, 2002, 10 (03) : 223 - 227
  • [9] Hintschich C, 2001, OPHTHALMOLOGE, V98, P74, DOI 10.1007/s003470170203
  • [10] CURRENT TECHNIQUES OF ENUCLEATION - A SURVEY OF 5,439 INTRAORBITAL IMPLANTS AND A REVIEW OF THE LITERATURE
    HORNBLASS, A
    BIESMAN, BS
    EVIATAR, JA
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 11 (02) : 77 - 86