Accuracy of Implant Impressions for Partially and Completely Edentulous Patients: A Systematic Review

被引:196
作者
Papaspyridakos, Panos [1 ,2 ]
Chen, Chun-Jung [3 ]
Gallucci, German O. [4 ]
Doukoudakis, Asterios [2 ]
Weber, Hans-Peter [5 ]
Chronopoulos, Vasilios [2 ,6 ]
机构
[1] Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, Boston, MA 02111 USA
[2] Univ Athens, Sch Dent, Dept Prosthodont, Athens 11528, Greece
[3] Chi Mei Med Ctr, Dept Dent, Tainan, Taiwan
[4] Harvard Univ, Sch Dent Med, Div Regenerat & Implant Sci, Boston, MA 02115 USA
[5] Tufts Univ, Sch Dent Med, Dept Prosthodont & Operat Dent, Boston, MA 02111 USA
[6] Griffith Univ, Sch Dent & Oral Hlth, Dept Restorat Dent, Gold Coast, Qld, Australia
关键词
accuracy; dental implants; digital impressions; edentulous; implant impressions; impression techniques; INTERNAL-CONNECTION IMPLANTS; INTRAORAL DIGITAL IMPRESSION; CODED HEALING ABUTMENTS; MASTER CAST ACCURACY; IN-VITRO; OSSEOINTEGRATED IMPLANTS; SUPPORTED PROSTHESIS; MULTIPLE IMPLANTS; DENTAL IMPLANTS; DIMENSIONAL ACCURACY;
D O I
10.11607/jomi.3625
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the accuracy of digital and conventional impression techniques for partially and completely edentulous patients and to determine the effect of different variables on the accuracy outcomes. Materials and Methods: An electronic and manual search was conducted to identify studies reporting on the accuracy of implant impressions. Pooled data were descriptively analyzed. Factors affecting the accuracy were identified, and their impact on accuracy outcomes was assessed. Results: The 76 studies that fulfilled the inclusion criteria featured 4 clinical studies and 72 in vitro studies. Studies were grouped according to edentulism; 41 reported on completely edentulous and 35 on partially edentulous patients. For completely edentulous patients, most in vitro studies and all three clinical studies demonstrated better accuracy with the splinted vs the nonsplinted technique (15 studies, splint; 1, nonsplint; 9, no difference). One clinical study and half of the in vitro studies reported better accuracy with the open-tray vs the closed-tray technique (10 studies, open-tray; 1, closed-tray; 10, no difference). For partially edentulous patients, one clinical study and most in vitro studies showed better accuracy with the splinted vs the nonsplinted technique (8 studies, splint; 2, nonsplint; 3, no difference). The majority of in vitro studies showed better accuracy with the open-tray vs the closed-tray technique (10 studies, open-tray; 1, closed-tray; 7, no difference), but the only clinical study reported no difference. Conclusion: The splinted impression technique is more accurate for both partially and completely edentulous patients. The open-tray technique is more accurate than the closed-tray for completely edentulous patients, but for partially edentulous patients there seems to be no difference. The impression material (polyether or polyvinylsiloxane) has no effect on the accuracy. The implant angulation affects the accuracy of implant impressions, while there are insufficient studies for the effect of implant connection type. Further accuracy studies are needed regarding digital implant impressions.
引用
收藏
页码:836 / +
页数:20
相关论文
共 113 条
[1]   ANALYSIS OF THREE-DIMENSIONAL DISTORTION OF TWO IMPRESSION MATERIALS IN THE TRANSFER OF DENTAL IMPLANTS [J].
Aguilar, Maria L. ;
Elias, Augusto ;
Vizcarrondo, Carlos E. Toro ;
Psoter, Walter J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2010, 103 (04) :202-209
[2]   Effects of Implant Angulation, Impression Material, and Variation in Arch Curvature Width on Implant Transfer Model Accuracy [J].
Akalin, Zerrin Fidan ;
Ozkan, Yasemin Kulak ;
Ekerim, Ahmet .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) :149-157
[3]  
Akça K, 2004, INT J ORAL MAX IMPL, V19, P517
[4]  
Al Quran FA, 2012, QUINTESSENCE INT, V43, P119
[5]   AN IN VITRO COMPARISON OF THE ACCURACY OF IMPLANT IMPRESSIONS WITH CODED HEALING ABUTMENTS AND DIFFERENT IMPLANT ANGULATIONS [J].
Al-Abdullah, Khaled ;
Zandparsa, Roya ;
Finkelman, Matthew ;
Hirayama, Hiroshi .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (02) :90-100
[6]   Effect of Multiple Use of Impression Copings on the Accuracy of Implant Transfer [J].
Alikhasi, Marzieh ;
Bassir, Seyed Hossein ;
Naini, Roshanak Baghai .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) :408-414
[7]   Three-Dimensional Accuracy of Implant and Abutment Level Impression Techniques: Effect on Marginal Discrepancy [J].
Alikhasi, Marzieh ;
Siadat, Hakimeh ;
Monzavi, Abbas ;
Momen-Heravi, Fatemeh .
JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (06) :649-657
[8]   Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study [J].
Andriessen, Frank S. ;
Riikens, David R. ;
van der Meer, Wither J. ;
Wismeijer, Daniell W. .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03) :186-194
[9]  
Assif D, 1996, Int J Oral Maxillofac Implants, V11, P216
[10]  
Assif D, 1999, INT J ORAL MAX IMPL, V14, P885