Multiplexed detection of DOCK8, PGM3 and STAT3 proteins for the diagnosis of Hyper-Immunoglobulin E syndrome using gold nanoparticles-based immunosensor array platform

被引:18
作者
Eissa, Shimaa [1 ]
Abdulkarim, Haya [1 ]
Dasouki, Majed [2 ]
Al Mousa, Hamoud [3 ]
Arnout, Rand [3 ]
Al Saud, Bandar [3 ]
Rahman, Anas Abdel [2 ]
Zourob, Mohammed [1 ,2 ]
机构
[1] Alfaisal Univ, Dept Chem, Al Zahrawi St, Al Maather,Takhassusi Rd, Riyadh 11533, Saudi Arabia
[2] King Faisal Specialist Hosp & Res Ctr, Zahrawi St, Riyadh 11211, Saudi Arabia
[3] King Faisal Specialist Hosp & Res Ctr, Dept Pediat, Sect Pediat Allergy & Immunol, Riyadh, Saudi Arabia
关键词
Biosensor; Dedicator of cytokinesis 8 (DOCK8); Signal transducer and activator of transcription 3 (STAT3); Phosphoglucomutase 3 (PGM3); Multiplex detection; CYTOKINESIS; 8; DOCK8; IGE SYNDROME; ELECTROCHEMICAL BIOSENSOR; CLINICAL-FEATURES; ATOPIC-DERMATITIS; MUTATIONS; DEFICIENCY; DEDICATOR; DISEASE;
D O I
10.1016/j.bios.2018.06.058
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Multiplexed biosensors hold great promise for early diagnosis of diseases where the detection of multiple biomarkers is required. Hyper Immunoglobulin E syndromes (HIES) are rare primary immunodeficiency disorders associated with mutations either in the signal transducer and activator of transcription 3 (STAT3), dedicator of cytokinesis 8 DOCK8) or phosphoglucomutase 3 (PGM3) genes. Yet, the diagnosis of HIES is challenged by the complexity of the existing laboratory assays. Here, we report for the first time the development of a multiplexed electrochemical immunosensor for the simultaneous detection of DOCK8, STAT3 and PGM3 proteins. The immunosensor was constructed on carbon array electrodes that were first modified by electrodeposition of gold nanoparticles (AuNPs). The array electrodes were then used to immobilize specific antibodies for the three proteins after the functionalization of the electrodes with cysteamine/glutaraldehyde linkers. The simultaneous detection of the DOCK8, PGM3 and STAT3 proteins was successfully realized by the immunosensor with respective limits of detections of 3.1, 2.2 and 3.5 pg/ml. The immunosensor has shown good sensitivity as well as selectivity against other proteins such as cystic fibrosis transmembrane conductance regulator (CFTR) and Duchenne Muscular Dystrophy (DMD). Moreover, the immunosensor was successfully applied in human serum samples showing capability to distinguish the HIES from the control samples.
引用
收藏
页码:613 / 619
页数:7
相关论文
共 22 条
[1]  
Aydin S., 2015, J CLIN IMMUNOL
[2]   DOCK8 deficiency: Insights into pathophysiology, clinical features and management [J].
Biggs, Catherine M. ;
Keles, Sevgi ;
Chatila, Talal A. .
CLINICAL IMMUNOLOGY, 2017, 181 :75-82
[3]   Autosomal Dominant STAT3 Deficiency and Hyper-IgE Syndrome Molecular, Cellular, and Clinical Features From a French National Survey [J].
Chandesris, Marie-Olivia ;
Melki, Isabelle ;
Natividad, Angels ;
Puel, Anne ;
Fieschi, Claire ;
Yun, Ling ;
Thumerelle, Caroline ;
Oksenhendler, Eric ;
Boutboul, David ;
Thomas, Caroline ;
Hoarau, Cyrille ;
Lebranchu, Yvon ;
Stephan, Jean-Louis ;
Cazorla, Celine ;
Aladjidi, Nathalie ;
Micheau, Marguerite ;
Tron, Francois ;
Baruchel, Andre ;
Barlogis, Vincent ;
Palenzuela, Gilles ;
Mathey, Catherine ;
Dominique, Stephane ;
Body, Gerard ;
Munzer, Martine ;
Fouyssac, Fanny ;
Jaussaud, Rolland ;
Bader-Meunier, Brigitte ;
Mahlaoui, Nizar ;
Blanche, Stephane ;
Debre, Marianne ;
Le Bourgeois, Muriel ;
Gandemer, Virginie ;
Lambert, Nathalie ;
Grandin, Virginie ;
Ndaga, Stephanie ;
Jacques, Corinne ;
Harre, Chantal ;
Forveille, Monique ;
Alyanakian, Marie-Alexandra ;
Durandy, Anne ;
Bodemer, Christine ;
Suarez, Felipe ;
Hermine, Olivier ;
Lortholary, Olivier ;
Casanova, Jean-Laurent ;
Fischer, Alain ;
Picard, Capucine .
MEDICINE, 2012, 91 (04) :E1-E19
[4]   Competitive voltammetric morphine immunosensor using a gold nanoparticle decorated graphene electrode [J].
Eissa, Shimaa ;
Zourob, Mohammed .
MICROCHIMICA ACTA, 2017, 184 (07) :2281-2289
[5]   Aptamer-Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood [J].
Eissa, Shimaa ;
Zourob, Mohammed .
SCIENTIFIC REPORTS, 2017, 7
[6]   Aptamer-based competitive electrochemical biosensor for brevetoxin-2 [J].
Eissa, Shimaa ;
Siaj, Mohamed ;
Zourob, Mohammed .
BIOSENSORS & BIOELECTRONICS, 2015, 69 :148-154
[7]   Large deletions and point mutations involving the dedicator of cytokinesis 8 (DOCK8) in the autosomal-recessive form of hyper-IgE syndrome [J].
Engelhardt, Karin R. ;
McGhee, Sean ;
Winkler, Sabine ;
Sassi, Atfa ;
Woellner, Cristina ;
Lopez-Herrera, Gabriela ;
Chen, Andrew ;
Kim, Hong Sook ;
Lloret, Maria Garcia ;
Schulze, Ilka ;
Ehl, Stephan ;
Thiel, Jens ;
Pfeifer, Dietmar ;
Veelken, Hendrik ;
Niehues, Tim ;
Siepermann, Kathrin ;
Weinspach, Sebastian ;
Reisli, Ismail ;
Keles, Sevgi ;
Genel, Ferah ;
Kutuculer, Necil ;
Camcioglu, Yildiz ;
Somer, Ayper ;
Karakoc-Aydiner, Elif ;
Barlan, Isil ;
Gennery, Andrew ;
Metin, Ayse ;
Degerliyurt, Aydan ;
Pietrogrande, Maria C. ;
Yeganeh, Mehdi ;
Baz, Zeina ;
Al-Tamemi, Salem ;
Klein, Christoph ;
Puck, Jennifer M. ;
Holland, Steven M. ;
McCabe, Edward R. B. ;
Grimbacher, Bodo ;
Chatila, Talal A. .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2009, 124 (06) :1289-1302
[8]  
Freeman A.F., 2008, ALLERGY CLIN N AM, V28, P277
[9]   Hyper-IgE Syndromes and the Lung [J].
Freeman, Alexandra F. ;
Olivier, Kenneth N. .
CLINICS IN CHEST MEDICINE, 2016, 37 (03) :557-+
[10]   STAT3 mutations in the hyper-IgE syndrome [J].
Holland, Steven M. ;
Deleo, Frank R. ;
Elloumi, Houda Z. ;
Hsu, Amy P. ;
Uzel, Gulbu ;
Brodsky, Nina ;
Freeman, Alexandra F. ;
Demidowich, Andrew ;
Davis, Joie ;
Turner, Maria L. ;
Anderson, Victoria L. ;
Darnell, Dirk N. ;
Welch, Pamela A. ;
Kuhns, Douglas B. ;
Frucht, David M. ;
Malech, Harry L. ;
Gallin, John I. ;
Kobayashi, Scott D. ;
Whitney, Adeline R. ;
Voyich, Jovanka M. ;
Musser, James M. ;
Woellner, Cristina ;
Schaeffer, Alejandro A. ;
Puck, Jennifer M. ;
Grimbacher, Bodo .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (16) :1608-1619