Prospective observational study of serial cardiac output by transthoracic echocardiography in healthy pregnant women undergoing elective caesarean delivery

被引:20
作者
Dennis, A. [1 ]
Arhanghelschi, I. [2 ]
Simmons, S. [1 ]
Royse, C. [3 ,4 ]
机构
[1] Mercy Hosp Women, Dept Anaesthesia, Heidelberg, Vic 3084, Australia
[2] St Vincents Hosp Fitzroy & Anaesthesia, Melbourne, Vic, Australia
[3] Univ Melbourne, Dept Pharmacol, Pain Management Unit, Parkville, Vic 3052, Australia
[4] Univ Melbourne, Royal Melbourne Hosp, Dept Anaesthesia & Pain Management, Parkville, Vic, Australia
关键词
Transthoracic echocardiography; Caesarean delivery; Pregnancy; Posture; Position; Cardiac output; Stroke volume; Velocity time integral; AORTOCAVAL COMPRESSION; STANDARDS COMMITTEE; OF-ECHOCARDIOGRAPHY; EPIDURAL-ANESTHESIA; HEMODYNAMIC-CHANGES; DIASTOLIC FUNCTION; SPINAL-ANESTHESIA; LATERAL TILT; DOPPLER; POSITION;
D O I
10.1016/j.ijoa.2009.06.007
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: An understanding of cardiovascular changes in parturients is crucial for their anaesthetic management, but few studies have examined the effect of posture on cardiac output in the peripartum period. Method: Cardiac output was measured in four different positions by transthoracic echocardiography (Doppler) in 30 term women undergoing elective caesarean delivery. These positions were left lateral level (P1), left lateral with 20 degrees head up (P2), left lateral with 10 head down (P3) measured preoperatively and supine (P4) measured postoperatively. Results: Mean +/- SD cardiac output was 4407 +/- 1109 mL/min (P1), 4182 +/- 825 mL/min (P2), 4031 +/- 798 mL/min (P3) and 4641 +/- 1064 mL/min (P4). Cardiac output was significantly less in P3 than in P1 (P = 0.049) due to a lower P3 velocity time integral compared with P1 (P = 0.020). Postoperatively, in the supine position, there was no difference in cardiac output, although there was a lower heart rate (P = <0.001) and increased velocity time integral (P = <0.001) compared with P1. The mean differences in interobserver measurements were 0.02 cm (left ventricular outflow tract) and -1.06 cm (velocity time integral). The mean differences in intraobserver measurements were 0.00 cm (left ventricular outflow tract) and -0.22 cm (velocity time integral). Echocardiography was well accepted by all women. Eight women found the left lateral 10 head-down position (P3) uncomfortable due to dizziness, headache, or increased abdominal pressure. Conclusions: Cardiac output showed large variability and was lower than previously reported. Cardiac output decreased with the left lateral 10 degrees head-down position due to a reduction in stroke volume that has not previously been reported. The transthoracic examination was acceptable to all women. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:142 / 148
页数:7
相关论文
共 43 条
  • [31] ROBSON SC, 1988, BRIT HEART J, V59, P680
  • [32] COMBINED DOPPLER AND ECHOCARDIOGRAPHIC MEASUREMENT OF CARDIAC-OUTPUT - THEORY AND APPLICATION IN PREGNANCY
    ROBSON, SC
    DUNLOP, W
    MOORE, M
    HUNTER, S
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1987, 94 (11): : 1014 - 1027
  • [33] HEMODYNAMIC-CHANGES DURING THE PUERPERIUM - A DOPPLER AND M-MODE ECHOCARDIOGRAPHIC STUDY
    ROBSON, SC
    HUNTER, S
    MOORE, M
    DUNLOP, W
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1987, 94 (11): : 1028 - 1039
  • [34] HEMODYNAMIC-CHANGES ASSOCIATED WITH CESAREAN-SECTION UNDER EPIDURAL-ANESTHESIA
    ROBSON, SC
    DUNLOP, W
    HUNTER, S
    BOYS, R
    BRYSON, M
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1989, 96 (06): : 642 - 647
  • [35] Russell IF, 2008, INT J OBSTET ANESTH, V17, P343, DOI [10.1016/j.ijoa.2008.03.008, 10.1016/j.ijoa.2008.03.007]
  • [36] Spinal anaesthesia - Sitting or lateral positions?
    Russell, IF
    [J]. ANAESTHESIA, 1996, 51 (02) : 198 - 199
  • [37] Structural and functional changes in left ventricle during normotensive and preeclamptic pregnancy
    Simmons, LA
    Gillin, AG
    Jeremy, RW
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2002, 283 (04): : H1627 - H1633
  • [38] EFFECTS OF MILD TRENDELENBURG ON CENTRAL HEMODYNAMICS AND INTERNAL JUGULAR-VEIN VELOCITY, CROSS-SECTIONAL AREA, AND FLOW
    TERAI, C
    ANADA, H
    MATSUSHIMA, S
    SHIMIZU, S
    OKADA, Y
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1995, 13 (03) : 255 - 258
  • [39] USE OF CARDIAC INDEX IN PREGNANCY - IS IT JUSTIFIED
    VANOPPEN, AC
    VANDERTWEEL, I
    DUVEKOT, JJ
    BRUINSE, HW
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 173 (03) : 923 - 928
  • [40] Cardiac output in normal pregnancy: A critical review
    vanOppen, ACC
    Stigter, RH
    Bruinse, HW
    [J]. OBSTETRICS AND GYNECOLOGY, 1996, 87 (02) : 310 - 318