Development of a cost-effective modular SPECT/CT scanner

被引:40
|
作者
Bailey, Dale L. [1 ]
Roach, Paul J.
Bailey, Elizabeth A.
Hewlett, James
Keijzers, Ronnie
机构
[1] Royal N Shore Hosp, Dept Nucl Med, Sydney, NSW, Australia
[2] Univ Sydney, Sch Phys & Med Radiat Sci, Sydney, NSW 2006, Australia
[3] Insight Oceania, Sydney, NSW, Australia
[4] Nucl Fields Aust Pty Ltd, Sydney, NSW, Australia
关键词
tomography; emission computed; SPECT; radionuclide imaging; X-ray CT;
D O I
10.1007/s00259-006-0364-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop a combined SPECT/CT based on a conventional gamma camera with the following design goals: (i) the subject is scanned on the same bed without moving between SPECT and CT scans, (ii) maintenance of full diagnostic utility of both scanners, (iii) a minimal equipment footprint which is adaptable to different site configurations, (iv) a modular design so that either scanner can be upgraded without impacting the other scanner and (v) cost-effectiveness. Methods A Philips SKYLight gamma camera was combined with a single-slice helical CT. The CT bed has been modified by mounting on wheels and is attached to a track in the floor when required. The CT bed is used for both the CT and the SPECT scans. The CT bed is parked outside the SKYLight's active area when not required. The CT data are used for anatomical localisation, attenuation correction and definition of anatomical boundaries (e.g. lobar boundaries in the lungs). Results The combined SPECT/CT system is installed in a 6.2 m x 4.6 m room. The CT can scan up to 1.3 m of the subject, which is usually sufficient for registration with the SPECT scan. More than 200 subjects have had SPECT/CT scans in the first year of operation. Initially, the main outcome has been improved confidence of localisation of abnormalities. Attenuation correction for all relevant radionuclides has been implemented. Conclusion We have developed a combined SPECT/CT using a novel approach based on a low-cost CT scanner. The design is compact, is readily upgradeable and does not compromise either machine's diagnostic or functional capabilities.
引用
收藏
页码:1415 / 1426
页数:12
相关论文
共 31 条
  • [1] Development of a cost-effective modular SPECT/CT scanner
    Dale L. Bailey
    Paul J. Roach
    Elizabeth A. Bailey
    James Hewlett
    Ronnie Keijzers
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 1415 - 1426
  • [2] Simulation and evaluation of high-performance cost-effective positron emission mammography scanner
    Musa, M. S.
    Ozsahin, D. Uzun
    Ozsahin, I.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [3] Cost-effective utilization of single photon emission computed tomography (SPECT) in decision making for epilepsy surgery
    Rathore, Chaturbhuj
    Kesavadas, Chandrasekhar
    Ajith, Joy
    Sasikala, Achikanath
    Sarma, Sankara P.
    Radhakrishnan, Kurupath
    SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2011, 20 (02): : 107 - 114
  • [4] Large-Area SiPM Pixels (LASiPs): A cost-effective solution towards compact large SPECT cameras
    Guberman, D.
    Paoletti, R.
    Rugliancich, A.
    Wunderlich, C.
    Passeri, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 : 171 - 184
  • [5] High resolution SPECT imaging for visualization of intratumoral heterogeneity using a SPECT/CT scanner dedicated for small animal imaging
    Izumi O. Umeda
    Kotaro Tani
    Keisuke Tsuda
    Masamitsu Kobayashi
    Mayumi Ogata
    Sadaaki Kimura
    Mitsuyoshi Yoshimoto
    Shuji Kojima
    Kunikazu Moribe
    Keiji Yamamoto
    Noriyuki Moriyama
    Hirofumi Fujii
    Annals of Nuclear Medicine, 2012, 26 : 67 - 76
  • [6] High resolution SPECT imaging for visualization of intratumoral heterogeneity using a SPECT/CT scanner dedicated for small animal imaging
    Umeda, Izumi O.
    Tani, Kotaro
    Tsuda, Keisuke
    Kobayashi, Masamitsu
    Ogata, Mayumi
    Kimura, Sadaaki
    Yoshimoto, Mitsuyoshi
    Kojima, Shuji
    Moribe, Kunikazu
    Yamamoto, Keiji
    Moriyama, Noriyuki
    Fujii, Hirofumi
    ANNALS OF NUCLEAR MEDICINE, 2012, 26 (01) : 67 - 76
  • [7] Evaluation of the annual occupational effective doses in a SPECT/CT department
    Aamry, Ali
    Sulieman, Abdelmoneim
    Tamam, N.
    Abuhadi, Nouf H. H.
    Johary, Yehia
    Aamri, Hussin
    Mattar, E.
    Salah, Hassan
    Osman, Hamid
    Khandaker, Mayeen Uddin
    Bradley, David
    APPLIED RADIATION AND ISOTOPES, 2022, 181
  • [8] Development of a cost-effective compact diode-laser-based photoacoustic sensing instrument for breast tissue diagnosis
    Khan, Suhel
    Mukhopadhyay, Sramana
    Vasudevan, Srivathsan
    Goel, Garima
    Joshi, Deepti
    Kapoor, Neelkamal
    Das, Saikat
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29 (01)
  • [9] Development of a Protocol for SPECT/CT in the Assessment of Wrist Disorders
    Le Corre, Aude
    Kym Phuong Huynh
    Dhaliwal, Rasmeet Singh
    Bain, Gregory Ian
    JOURNAL OF WRIST SURGERY, 2016, 5 (04) : 297 - 305
  • [10] Development of a compact and cost-effective PET detector module for a small-animal PET system with FESA ASIC
    Wang, M.
    Wang, Y.
    Zhang, X.
    Song, Z.
    Zhou, X.
    Hu, Y.
    Zhou, Y.
    Wu, B.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (09)