Dynamic assessment of the wrist after total wrist arthroplasty

被引:8
作者
Singh, H. P. [1 ]
Bhattacharjee, D. [1 ]
Dias, J. J. [1 ]
Trail, I. [2 ]
机构
[1] Leicester Gen Hosp, Dept Orthopaed Surg, Gwendolen Rd, Leicester LE5 4PW, Leics, England
[2] Wrightington Hosp, Wigan, England
关键词
Dynamic assessment; total wrist arthroplasty; traumatic osteoarthritis; PROXIMAL ROW CARPECTOMY; DART-THROWING MOTION; HAND FUNCTION-TEST; RHEUMATOID-ARTHRITIS; OUTCOMES; OSTEOARTHRITIS; FUSION; QUESTIONNAIRE; ARTHRODESIS; AMANDYS(R);
D O I
10.1177/1753193417690472
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Our aim was to assess the outcome in patients with total wrist arthroplasty performed for end stage wrist osteoarthritis. We analysed the ranges of motion of operated and un-operated wrists using a flexible electrogoniometer during the Sollerman hand function test. We assessed grip strength with a digital dynamometer and completed patient reported outcome scores more than one year post-operatively. We reviewed 12 patients with a mean age of 64 (range 48-82) years. The flexion-extension arc was 72% and radioulnar deviation arc was 53% of the un-operated side but the total range of motion (area of circumduction) was 43% of the un-operated side and only 20% of the circumduction in age and gender-matched normal volunteers. Peak grip strength was 68% of the un-operated side. The patients reported good outcome with mean Michigan Hand Questionnaire (MHQ) scores of 56 (range 25-84) and mean Patient Evaluation Measure (PEM) scores of 39 (range 20-68). Patients completed the activities of Sollerman hand function test in twice the time (6 min) as required for a normal volunteer (2.8 min). The circumduction ellipses were narrow and central with limited radio-ulnar deviation and small mean areas of motion during activities of daily living.
引用
收藏
页码:573 / 579
页数:7
相关论文
共 33 条
[1]  
Adams BD, 2004, ORTHOPEDICS, V27, P278
[2]  
Adams Brian D, 2004, Tech Hand Up Extrem Surg, V8, P130, DOI 10.1097/01.bth.0000131199.39073.2a
[3]   Reliability and validity of an electronic dynamometer for measuring grip strength [J].
Allen, Deborah ;
Barnett, Fiona .
INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2011, 18 (05) :258-264
[4]   Pyrocarbon Interposition Wrist Arthroplasty in the Treatment of Failed Wrist Procedures [J].
Bellemere, Philippe ;
Maes-Clavier, Catherine ;
Loubersac, Thierry ;
Gaisne, Etienne ;
Kerjean, Yves ;
Collon, Sylvie .
JOURNAL OF WRIST SURGERY, 2012, 1 (01) :31-38
[5]   Can Total Wrist Arthroplasty Be an Option in the Treatment of the Severely Destroyed Posttraumatic Wrist? [J].
Boeckstyns, Michel E. H. ;
Herzberg, Guillaume ;
Sorensen, Allan Ibsen ;
Axelsson, Peter ;
Kroner, Karsten ;
Liverneaux, Philippe A. ;
Obert, Laurent ;
Merser, Soren .
JOURNAL OF WRIST SURGERY, 2013, 2 (04) :324-329
[6]   A systematic review of total wrist arthroplasty compared with total wrist arthrodesis for rheumatoid arthritis [J].
Cavaliere, Christi M. ;
Chung, Kevin C. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 122 (03) :813-825
[7]   Reliability and validity testing of the Michigan Hand Outcomes Questionnaire [J].
Chung, KC ;
Pillsbury, MS ;
Walters, MR ;
Hayward, RA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04) :575-587
[8]   Early results of a prospective study on the pyrolytic carbon (pyrocarbon) Amandys® for osteoarthritis of the wrist [J].
Daruwalla, Z. J. ;
Davies, K. L. ;
Shafighian, A. ;
Gillham, N. R. .
ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2012, 94 (07) :496-501
[9]   Assessing the outcome of disorders of the hand - Is the patient evaluation measure reliable, valid, responsive and without bias? [J].
Dias, JJ ;
Bhowal, B ;
Wildin, CJ ;
Thompson, JR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (02) :235-240
[10]   Total wrist fusion - A functional assessment [J].
Field, J ;
Herbert, TJ ;
Prosser, R .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1996, 21B (04) :429-433