Enhancement of biological oxygen demand detection with a microbial fuel cell using potassium permanganate as cathodic electron acceptor

被引:26
作者
Wang, Siqi [1 ]
Tian, Shuai [1 ]
Zhang, Panyue [1 ]
Ye, Junpei [1 ]
Tao, Xue [1 ]
Li, Fan [1 ]
Zhou, Zeyan [1 ]
Nabi, Mohammad [1 ]
机构
[1] Beijing Forestry Univ, Beijing Key Lab Source Control Technol Water Poll, Beijing 100083, Peoples R China
基金
中国国家自然科学基金; 高等学校博士学科点专项科研基金;
关键词
Biochemical oxygen demand; Microbial fuel cell; KMnO4; Detection limit; Response time; WASTE-WATER TREATMENT; BOD; PERFORMANCE; BIOSENSOR; SENSOR;
D O I
10.1016/j.jenvman.2019.109682
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
When dual-chamber microbial fuel cell (MFC) is used to detect biochemical oxygen demand (BOD), dissolved oxygen is traditionally used as cathodic electron acceptor. The detection limit of this MFC-based BOD biosensor is usually lower than 200 mg/L. In this paper, the startup of MFC-based BOD biosensor was researched and the external resistor of MFC was optimized. Results showed that the MFC started up with the dissolved oxygen as cathodic electron acceptor within 10 d, and the external resistor was optimized as 500 (2 to ensure the maximum output power of MFC. Dissolved oxygen and potassium permanganate (KMnO4) were used as cathodic electron acceptor to run MFC for detection of wastewater BOD, and the performances of two kinds of BOD biosensors were compared. The MFC-based BOD biosensor using KMnO4 (10 mmol/L) as cathodic electron acceptor exhibited an excellent performance, compared with that using dissolved oxygen. The upper limit of BOD detection was greatly broadened to 500 mg/L, the response time was shortened by 50% for artificial wastewater with a BOD of 100 mg/L, and the relative error of BOD detection was reduced to less than 10%. The MFC-based BOD biosensor using KMnO4 as cathodic electron acceptor showed a better linear relationship (R-2 > 0.992) between the electric charge and BOD concentration within a BOD range of 25-500 mg/L. The MFC-based BOD biosensor using the KMnO4 as cathodic electron acceptor is promising with a better application prospect.
引用
收藏
页数:7
相关论文
共 41 条
  • [1] Domestic wastewater treatment and power generation in continuous flow air-cathode stacked microbial fuel cell: Effect of series and parallel configuration
    Baltazar Estrada-Arriaga, Edson
    Hernandez-Romano, Jesus
    Garcia-Sanchez, Liliana
    Guillen Garces, Rosa Angelica
    Obed Bahena-Bahena, Erick
    Guadarrama-Perez, Oscar
    Moeller Chavez, Gabriela Eleonora
    [J]. JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2018, 214 : 232 - 241
  • [2] Effect of cathode electron acceptors on simultaneous anaerobic sulfide and nitrate removal in microbial fuel cell
    Cai, Jing
    Zheng, Ping
    Mahmood, Qaisar
    [J]. WATER SCIENCE AND TECHNOLOGY, 2016, 73 (04) : 947 - 954
  • [3] Development of a rapid ferricyanide-mediated assay for biochemical oxygen demand using a mixed microbial consortium
    Catterall, K
    Zhao, HJ
    Pasco, N
    John, R
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (11) : 2584 - 2590
  • [4] Continuous determination of biochemical oxygen demand using microbial fuel cell type biosensor
    Chang, IS
    Jang, JK
    Gil, GC
    Kim, M
    Kim, HJ
    Cho, BW
    Kim, BH
    [J]. BIOSENSORS & BIOELECTRONICS, 2004, 19 (06) : 607 - 613
  • [5] Performance of sodium bromate as cathodic electron acceptor in microbial fuel cell
    Dai, Hongyan
    Yang, Huimin
    Liu, Xian
    Zhao, Yu
    Liang, Zhenhai
    [J]. BIORESOURCE TECHNOLOGY, 2016, 202 : 220 - 225
  • [6] Potassium permanganate as an electron receiver in a microbial fuel cell
    Eliato, Tahmineh Rahmani
    Pazuki, Gholamreza
    Majidian, Nasrollah
    [J]. ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2016, 38 (05) : 644 - 651
  • [7] Continuous electricity generation by a graphite granule baffled air-cathode microbial fuel cell
    Feng, Yujie
    Lee, He
    Wang, Xin
    Liu, Yaolan
    He, Weihua
    [J]. BIORESOURCE TECHNOLOGY, 2010, 101 (02) : 632 - 638
  • [8] Operational parameters affecting the performance of a mediator-less microbial fuel cell
    Gil, GC
    Chang, IS
    Kim, BH
    Kim, M
    Jang, JK
    Park, HS
    Kim, HJ
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (04) : 327 - 334
  • [9] A microbial fuel cell as power supply for implantable medical devices
    Han, Yufeng
    Yu, Chaoling
    Liu, Hong
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 25 (09) : 2156 - 2160
  • [10] Hsieh M.C., 2015, SENSORS, V16, P1