Gas-permeable scleral contact lens therapy in ocular surface disease

被引:182
作者
Romero-Rangel, T
Stavrou, P
Cotter, J
Rosenthal, P
Baltatzis, S
Foster, CS
机构
[1] Harvard Univ, Massachusetts Eye & Ear Infirm, Sch Med,Ocular Immunol & Uveitis Serv, Dept Ophthalmol,Hilles Immunol Lab, Boston, MA 02114 USA
[2] Boston Fdn Sight, Boston, MA USA
[3] Univ Athens, Athens, Greece
关键词
D O I
10.1016/S0002-9394(00)00378-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To describe the therapeutic benefits of nonfenestrated gas-permeable scleral contact lenses in the management of patients with ocular surface disease. METHODS: The charts of 49 consecutive patients (76 eyes) with ocular surface disease whose management included the use of gas-permeable scleral contact lenses were reviewed. We also developed a questionnaire to assess the impact of lens wear on subjective aspects of activities of daily living. RESULTS: The mean age of the 49 patients was 44.6 years (range, 3 to 87 years); 31 patients were female and 18 mere male. The most common indication for fitting of the lenses was Stevens-Johnson syndrome (54 [71%] of the 76 eyes). Other indications included ocular cicatricial pemphigoid, exposure keratitis, toxic epidermal necrolysis, postherpetic keratitis, congenital deficiency of meibomian glands, superior limbal keratoconjunctivitis, Sjogren syndrome, and inflammatory corneal degeneration. The mean follow-up was 33.6 months (range, 2 to 144 months). Improvement in best corrected visual acuity (defined as a gain of 2 or more Snellen lines) was observed in 40 (53%) of the eyes, Zn eight (53%) of the 15 eyes with active corneal epithelial defects at the time of lens fitting, the defects healed, whereas in the remaining seven eyes the corneal epithelial defects remained unchanged. Forty-five (92%) of the 49 patients reported improvement in their quality of life as a result of reduction of photophobia and discomfort. The mean wearing time of the gas-permeable scleral contact lenses was 13.7 hours per day (range, 4 to 18 hours), Many patients had preparatory surgical procedures before lens fitting (for example, punctal occlusion or mucous membrane grafting), and some had visual rehabilitation surgical procedures (for example, keratoplasty and/or cataract surgery) after lens fitting. CONCLUSIONS: Gas-permeable scleral contact lens wear provides an additional effective strategy in the surface management and visual rehabilitation of patients with severe ocular surface disease. (C) 2000 by Elsevier Science inc. All rights reserved.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 34 条
[1]   Management of conjunctival cicatrizing diseases and severe ocular surface dysfunction [J].
Chiou, AGY ;
Florakis, GJ ;
Kazim, M .
SURVEY OF OPHTHALMOLOGY, 1998, 43 (01) :19-46
[2]  
Cotter J M, 1998, J Am Optom Assoc, V69, P33
[3]  
COTTER JM, 1998, CONTACT LENSES Q, P10
[4]  
Dallos J, 1936, ARCH OPHTHALMOL-CHIC, V15, P617
[5]   SATTLER VEIL [J].
DALLOS, J .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1946, 30 (10) :607-613
[6]  
de Boer C., 1978, PRACTICAL GUIDE SPLI
[7]  
Ezekiel D, 1983, J BR CONTACT LENS AS, V6, P158, DOI DOI 10.1016/S0141-7037(83)80064-0
[8]  
Feinbloom W., 1937, AM J OPTOM, V14, P41, DOI DOI 10.1097/00006324-193702000-00001
[9]  
Fick AE., 1888, Arch Ophthalmol, V17, P215
[10]  