An improvement in IMRT QA results and beam matching in linacs using statistical process control

被引:22
作者
Gagneur, Justin D. [1 ]
Ezzell, Gary A. [1 ]
机构
[1] Mayo Clin Arizona, Dept Radiat Oncol, Phoenix, AZ 85054 USA
关键词
statistical process control; beam matching; IMRT QA; QUALITY-ASSURANCE; DELIVERY; MLC;
D O I
10.1120/jacmp.v15i5.4927
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to apply the principles of statistical process control (SPC) in the context of patient specific intensity-modulated radiation therapy (IMRT) QA to set clinic-specific action limits and evaluate the impact of changes to the multileaf collimator (MLC) calibrations on IMRT QA results. Ten months of IMRT QA data with 247 patient QAs collected on three beam-matched linacs were retrospectively analyzed with a focus on the gamma pass rate (GPR) and the average ratio between the measured and planned doses. Initial control charts and action limits were calculated. Based on this data, changes were made to the leaf gap parameter for the MLCs to improve the consistency between linacs. This leaf gap parameter is tested monthly using a MLC sweep test. A follow-up dataset with 424 unique QAs were used to evaluate the impact of the leaf gap parameter change. The initial data average GPR was 98.6% with an SPC action limit of 93.7%. The average ratio of doses was 1.003, with an upper action limit of 1.017 and a lower action limit of 0.989. The sweep test results for the linacs were -1.8%, 0%, and +1.2% from nominal. After the adjustment of the leaf gap parameter, all sweep test results were within 0.4% of nominal. Subsequently, the average GPR was 99.4% with an SPC action limit of 97.3%. The average ratio of doses was 0.997 with an upper action limit of 1.011 and a lower action limit of 0.981. Applying the principles of SPC to IMRT QA allowed small differences between closely matched linacs to be identified and reduced. Ongoing analysis will monitor the process and be used to refine the clinical action limits for IMRT QA.
引用
收藏
页码:190 / 195
页数:6
相关论文
共 10 条
[1]   Commissioning measurements for photon beam data on three TrueBeam linear accelerators, and comparison with Trilogy and Clinac 2100 linear accelerators [J].
Beyer, Gloria P. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01) :273-288
[2]   Statistical process control for IMRT dosimetric verification [J].
Breen, Stephen L. ;
Moseley, Douglas J. ;
Zhang, Beibei ;
Sharpe, Michael B. .
MEDICAL PHYSICS, 2008, 35 (10) :4417-4425
[3]   A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC) [J].
Gerard, Karine ;
Grandhaye, Jean-Pierre ;
Marchesi, Vincent ;
Kafrouni, Hanna ;
Husson, Francois ;
Aletti, Pierre .
MEDICAL PHYSICS, 2009, 36 (04) :1275-1285
[4]   Confidence limit variation for a single IMRT system following the TG119 protocol [J].
Gordon, J. D. ;
Krafft, S. P. ;
Jang, S. ;
Smith-Raymond, L. ;
Stevie, M. Y. ;
Hamilton, R. J. .
MEDICAL PHYSICS, 2011, 38 (03) :1641-1648
[5]   Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments [J].
Mancuso, Gordon M. ;
Fontenot, Jonas D. ;
Gibbons, John P. ;
Parker, Brent C. .
MEDICAL PHYSICS, 2012, 39 (07) :4378-4385
[6]   Biological consequences of MLC calibration errors in IMRT delivery and QA [J].
Moiseenko, Vitali ;
LaPointe, Vincent ;
James, Kerry ;
Yin, Lingshu ;
Liu, Mitchell ;
Pawlicki, Todd .
MEDICAL PHYSICS, 2012, 39 (04) :1917-1924
[7]   A statistical approach to IMRT patient-specific QA [J].
Palaniswaamy, Geethpriya ;
Brame, Ryan Scott ;
Yaddanapudi, Sridhar ;
Rangaraj, Dharanipathy ;
Mutic, Sasa .
MEDICAL PHYSICS, 2012, 39 (12) :7560-7570
[8]   Statistical process control for radiotherapy quality assurance [J].
Pawlicki, T ;
Whitaker, M ;
Boyer, AL .
MEDICAL PHYSICS, 2005, 32 (09) :2777-2786
[9]   Quality in radiation oncology [J].
Pawlicki, Todd ;
Mundt, Arno J. .
MEDICAL PHYSICS, 2007, 34 (05) :1529-1534
[10]   Tolerances on MLC leaf position accuracy for IMRT delivery with a dynamic MLC [J].
Rangel, Alejandra ;
Dunscombe, Peter .
MEDICAL PHYSICS, 2009, 36 (07) :3304-3309