Liquid chromatography-mass spectrometry and strategies for trace-level analysis of polar organic pollutants

被引:156
作者
Reemtsma, T [1 ]
机构
[1] Tech Univ Berlin, Dept Water Qual Control, D-10623 Berlin, Germany
关键词
reviews; water analysis; atmospheric pressure ionization; pollutants; polar;
D O I
10.1016/S0021-9673(03)00507-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-mass spectrometry using atmospheric pressure ionization (LC-API-MS) has drastically changed the analytical methods used to detect polar pollutants in water. The present status of application of this technique to organic water constituents is reviewed. The selection of the appropriate LC conditions, whether reversed-phase liquid chromatography, ion-pair chromatography, capillary electrophoresis or ion chromatography, and of the most sensitive ionization mode, electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI), depends upon the polarity and acidity of the analytes. Strongly acidic compounds such as aromatic sulfonates, sulfonated dyes, haloacedc acids, linear alkylbenzene sulfonates. aliphatic sulfonates and sulfates and complexing agents, weakly acidic compounds such as carboxylates and phenols, neutral compound classes, namely alkylphenol ethoxylates, alcohol ethoxylates and polycyclic aromatic hydrocarbons and the basic toxins, quaternary ammonium compounds and organometallic compounds are considered. The selection of the mass spectrometer depends upon the analytical task: triple-quadrupole mass spectrometers are highly suited for sensitive quantitation and for qualitative analyses, ion traps are especially suited for structure elucidation, whereas time-of-flight mass spectrometers and quadrupole time-of-flight mass spectrometers with their higher mass resolution are ideal for the determination of molecular formulas of unknown compounds and for screening purposes. While large steps have already been made, future efforts with respect to water analysis may be directed at fine-tuning the methodical arsenal for increased sensitivity and selectivity and to extend LC-MS application to transformation products. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:477 / 501
页数:25
相关论文
共 209 条
[1]   Determination of haloacetic acids by the combination of non-aqueous capillary electrophoresis and mass spectrometry [J].
Ahrer, W ;
Buchberger, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (07) :604-609
[2]   Analysis of low-molecular-mass inorganic and organic anions by ion chromatography-atmospheric pressure ionization mass spectrometry [J].
Ahrer, W ;
Buchberger, W .
JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) :275-287
[3]  
Airiau CY, 2001, RAPID COMMUN MASS SP, V15, P135, DOI 10.1002/1097-0231(20010130)15:2<135::AID-RCM204>3.0.CO
[4]  
2-Z
[5]   Solid phase extraction procedure of polar benzene- and naphthalenesulfonates in industrial effluents followed by unequivocal determination with ion pair chromatography/electrospray-mass spectrometry [J].
Alonso, MC ;
Castillo, M ;
Barceló, D .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2586-2593
[6]   DETERMINATION OF BENZENESULFONATES AND NAPHTHALENESULFONATES IN WASTE-WATER BY SOLID-PHASE EXTRACTION WITH GRAPHITIZED CARBON-BLACK AND ION-PAIR LIQUID-CHROMATOGRAPHY WITH UV DETECTION [J].
ALTENBACH, B ;
GIGER, W .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2325-2333
[7]   Derivatization of ethinylestradiol with dansyl chloride to enhance electrospray ionization: Application in trace analysis of ethinylestradiol in rhesus monkey plasma [J].
Anari, MR ;
Bakhtiar, R ;
Zhu, B ;
Huskey, S ;
Franklin, RB ;
Evans, DC .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4136-4144
[8]  
Ballantine JA, 1997, RAPID COMMUN MASS SP, V11, P630, DOI 10.1002/(SICI)1097-0231(199704)11:6<630::AID-RCM744>3.0.CO
[9]  
2-K
[10]   THE USE OF AMINE BASE TO ENHANCE THE SENSITIVITY OF ELECTROSPRAY MASS-SPECTROMETRY TOWARDS COMPLEX POLYSULFONATED AZO DYES [J].
BALLANTINE, JA ;
GAMES, DE ;
SLATER, PS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (14) :1403-1410