Design and Implementation of a Real-time Monitoring Platform for Optimal Sepsis Care in an Emergency Department: Observational Cohort Study

被引:2
作者
Lee, Andy Hung-Yi [1 ]
Aaronson, Emily [1 ]
Hibbert, Kathryn A. [2 ]
Flynn, Micah H. [3 ]
Rutkey, Hayley [3 ]
Mort, Elizabeth [2 ]
Sonis, Jonathan D. [1 ]
Safavi, Kyan C. [3 ]
机构
[1] Massachusetts Gen Hosp, Dept Emergency Med, 55 Fruit St, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Med, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02114 USA
关键词
electronic monitoring platform; sepsis; quality improvement; ALERT;
D O I
10.2196/26946
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Sepsis is the leading cause of death in US hospitals. Compliance with bundled care, specifically serial lactates, blood cultures, and antibiotics, improves outcomes but is often delayed or missed altogether in a busy practice environment. Objective: This study aims to design, implement, and validate a novel monitoring and alerting platform that provides real-time feedback to frontline emergency department (ED) providers regarding adherence to bundled care. Methods: This single-center, prospective, observational study was conducted in three phases: the design and technical development phase to build an initial version of the platform; the pilot phase to test and refine the platform in the clinical setting; and the postpilot rollout phase to fully implement the study intervention. Results: During the design and technical development, study team members and stakeholders identified the criteria for patient inclusion, selected bundle measures from the Center for Medicare and Medicaid Sepsis Core Measure for alerting, and defined alert thresholds, message content, delivery mechanisms, and recipients. Additional refinements were made based on 70 provider survey results during the pilot phase, including removing alerts for vasopressor initiation and modifying text in the pages to facilitate patient identification. During the 48 days of the postpilot rollout phase, 15,770 ED encounters were tracked and 711 patient encounters were included in the active monitoring cohort. In total, 634 pages were sent at a rate of 0.98 per attending physician shift. Overall, 38.3% (272/711) patients had at least one page. The missing bundle elements that triggered alerts included: antibiotics 41.6% (136/327), repeat lactate 32.4% (106/327), blood cultures 20.8% (68/327), and initial lactate 5.2% (17/327). Of the missing Sepsis Core Measures elements for which a page was sent, 38.2% (125/327) were successfully completed on time. Conclusions: A real-time sepsis care monitoring and alerting platform was created for the ED environment. The high proportion of patients with at least one alert suggested the significant potential for such a platform to improve care, whereas the overall number of alerts per clinician suggested a low risk of alarm fatigue. The study intervention warrants a more rigorous evaluation to ensure that the added alerts lead to better outcomes for patients with sepsis.
引用
收藏
页数:10
相关论文
共 21 条
  • [1] NEW MANDATED CENTERS FOR MEDICARE AND MEDICAID SERVICES REQUIREMENTS FOR SEPSIS REPORTING: CAUTION FROM THE FIELD
    Aaronson, Emily L.
    Filbin, Michael R.
    Brown, David F. M.
    Tobin, Kathy
    Mort, Elizabeth A.
    [J]. JOURNAL OF EMERGENCY MEDICINE, 2017, 52 (01) : 109 - 116
  • [2] Effects of workload, work complexity, and repeated alerts on alert fatigue in a clinical decision support system
    Ancker, Jessica S.
    Edwards, Alison
    Nosal, Sarah
    Hauser, Diane
    Mauer, Elizabeth
    Kaushal, Rainu
    [J]. BMC MEDICAL INFORMATICS AND DECISION MAKING, 2017, 17
  • [3] [Anonymous], HOSP COMP
  • [4] [Anonymous], SEVERE SEPSIS SEPTIC
  • [5] Electronic health record-based clinical decision support alert for severe sepsis: a randomised evaluation
    Downing, Norman Lance
    Rolnick, Joshua
    Poole, Sarah F.
    Hall, Evan
    Wessels, Alexander J.
    Heidenreich, Paul
    Shieh, Lisa
    [J]. BMJ QUALITY & SAFETY, 2019, 28 (09) : 762 - 768
  • [6] Sepsis With Preexisting Heart Failure: Management of Confounding Clinical Features
    Jones, Timothy W.
    Smith, Susan E.
    Van Tuyl, Joseph S.
    Newsome, Andrea Sikora
    [J]. JOURNAL OF INTENSIVE CARE MEDICINE, 2021, 36 (09) : 989 - 1012
  • [7] Digital Alerting and Outcomes in Patients With Sepsis: Systematic Review and Meta-Analysis
    Joshi, Meera
    Ashrafian, Hutan
    Arora, Sonal
    Khan, Sadia
    Cooke, Graham
    Darzi, Ara
    [J]. JOURNAL OF MEDICAL INTERNET RESEARCH, 2019, 21 (12)
  • [8] Hospital Deaths in Patients With Sepsis From 2 Independent Cohorts
    Liu, Vincent
    Escobar, Gabriel J.
    Greene, John D.
    Soule, Jay
    Whippy, Alan
    Angus, Derek C.
    Iwashyna, Theodore J.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (01): : 90 - 92
  • [9] Mannequin Simulation Identifies Common Surgical Intensive Care Unit Teamwork Errors Long After Introduction of Sepsis Guidelines
    Mah, John W.
    Bingham, Katherine
    Dobkin, Eric D.
    Malchiodi, Liza
    Russell, Ann
    Donahue, Steven
    Staff, Ilene
    Ivy, Michael E.
    Kirton, Orlando C.
    [J]. SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE, 2009, 4 (04): : 193 - 199
  • [10] Diagnostic accuracy and effectiveness of automated electronic sepsis alert systems: A systematic review
    Makam, Anil N.
    Nguyen, Oanh K.
    Auerbach, Andrew D.
    [J]. JOURNAL OF HOSPITAL MEDICINE, 2015, 10 (06) : 396 - 402