共 50 条
Breakthrough analysis of continuous fixed-bed adsorption of sevoflurane using activated carbons
被引:59
|作者:
Ang, Teck Nam
[1
]
Young, Brent R.
[1
]
Taylor, Matthew
[2
]
Burrell, Rob
[2
]
Aroua, Mohamed Kheireddine
[3
,4
]
Baroutian, Saeid
[1
]
机构:
[1] Univ Auckland, Fac Engn, Dept Chem & Mat Engn, Auckland, New Zealand
[2] Middlemore Hosp, Dept Anaesthesia, Counties Manukau Hlth, Auckland, New Zealand
[3] Sunway Univ, Ctr Carbon Dioxide Capture & Utilizat, Sch Sci & Technol, Subang Jaya, Malaysia
[4] Univ Lancaster, Dept Engn, Lancaster LA1 4YW, England
来源:
关键词:
Activated carbons;
Breakthrough characteristics;
Halogenated ether;
Hydrofluorocarbons;
Volatile anaesthetics;
VOLATILE ANESTHETICS;
INHALATION ANESTHETICS;
METHYLENE-BLUE;
REMOVAL;
PERFORMANCE;
ISOFLURANE;
PREDICTION;
ADSORBENT;
ZEOLITES;
RECOVERY;
D O I:
10.1016/j.chemosphere.2019.124839
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
The inhalational anaesthetic agent - sevoflurane is widely employed for the induction and maintenance of surgical anaesthesia. Sevoflurane possesses a high global warming potential that imposes negative impact to the environment. The only way to resolve the issue is to remove sevoflurane from the medical waste gas before it reaches the atmosphere. A continuous adsorption study with a fixed-bed column was conducted using two commercial granular activated carbons (E-GAC and H-GAC), to selectively remove sevoflurane. The effect of bed depth (Z, 5-15 cm), gas flow rate (Q 0.5-6.0 L/min) and inlet sevoflurane concentration (C-0, similar to 55-700 mg/L) was investigated. E-GAC demonstrated similar to 60% higher adsorption capacity than H-GAC under the same operating conditions. Varying the levels of Z, Q and C-0 showed significant differences in the adsorption capacities of E-GAC, whereas only changing the C-0 level had significant differences for H-GAC. Three breakthrough models (Adams-Bohart, Thomas, and YoonNelson) and Bed-depth/service time (BDST) analysis were applied to predict the breakthrough characteristics of the adsorption tests and determine the characteristic parameters of the column. The YoonNelson and Thomas model-predicted breakthrough curves were in good agreement with the experimental values. In the case of the Adams-Bohart model, a low correlation was observed. The predicted breakthrough time (t(b)) based on kinetic constant (k(BDST)) in BDST analysis showed satisfactory agreement with the measured values. The results suggest the possibility of designing, scaling up and optimising an adsorption system for removing sevoflurane with the aid of the models and BDST analysis. (C) 2019 Elsevier Ltd. All rights reserved.