Concerns about ceramics in THA

被引:103
作者
Barrack, RL
Barak, C
Skinner, HB
机构
[1] Washington Univ, Sch Med, St Louis, MO 63110 USA
[2] Tulane Univ, Hlth Sci Ctr, Dept Orthopaed Surg, New Orleans, LA 70118 USA
[3] UCI, Med Ctr, Dept Orthopaed Surg, Orange, CA USA
关键词
D O I
10.1097/01.blo.0000150132.11142.d2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Currently available ceramic materials are superior to those used originally in total hip arthroplasty, which should translate into a much lower complication rate than what has been reported previously. In spite of this, a number of concerns remain. The ceramic-on-ceramic articulation is not immune to wear and surface damage. Conditions associated with ceramic wear include vertical cup position, femoral neck impingement, and femoral head separation. A unique pattern of stripe wear has been described as something that results from microseparation during gait. Catastrophic failure, although rare, continues to be a concern, and not all fractures can be predicted by proof testing. Revisions needed because of ceramic fractures can be extensive, and the results of the revision procedures can be compromised by the presence of highly abrasive particulate debris that is retained. Other concerns include the generation of debris from modular interfaces, neck damage and debris generation from impingement of some designs, inability to use a ceramic head a second time on a metal trunnion, and the dramatic loss of head and liner options intraoperatively. Although ceramics show great promise as a lower wear articulation, manufacturing and design modifications and improvements will continue in an attempt to address the substantial concerns that persist.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 30 条
[1]   Revision total hip arthroplasty performed after fracture of a ceramic femoral head - A multicenter survivorship study [J].
Allain, J ;
Roudot-Thoraval, F ;
Delecrin, J ;
Anract, P ;
Migaud, H ;
Goutallier, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :825-830
[2]   Failure of a stainless-steel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head - A case report [J].
Allain, J ;
Goutallier, D ;
Voisin, MC ;
Lemouel, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (09) :1355-1360
[3]  
Barrack R L, 2001, Instr Course Lect, V50, P275
[4]   Impingement and rim wear associated with early osteolysis after a total hip replacement - A case report [J].
Barrack, RL ;
Schmalzried, TP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (07) :1218-1220
[5]   Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty [J].
Barrack, RL ;
Lavernia, C ;
Ries, M ;
Thornberry, R ;
Tozakoglou, E .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (04) :569-+
[6]  
Barrack RL, 1996, ORTHOPEDICS, V19, P741
[7]  
BEAVER RJ, 2003, BIOCERAMICS JOINT AR, P65
[8]   Wear debris from two different alumina-on-alumina total hip arthroplasties [J].
Böhler, M ;
Mochida, Y ;
Bauer, TW ;
Plenk, H ;
Salzer, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (06) :901-909
[9]  
EICKMANN TH, 2003, P 8 ANN BIOLOX S BER, P187
[10]   Mittelmeier ceramic-ceramic prosthesis after 10 years [J].
GarciaCimbrelo, E ;
MartinezSayanes, JM ;
Minuesa, A ;
Munuera, L .
JOURNAL OF ARTHROPLASTY, 1996, 11 (07) :773-781