Biomechanical evaluation of external ankle arthrodesis contact area and pressure distribution

被引:0
作者
Connor, CJ [1 ]
Nabhani, F [1 ]
机构
[1] Univ Teesside, Sch Sci & Technol, Middlesbrough, Cleveland, England
关键词
biomechanics; ankle; arthrodesis; contact;
D O I
10.1016/j.jmatprotec.2004.04.140
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The ankle is a joint that is often adversely affected by arthritis. This results in a painful and stiff joint. Ankle replacement is only suitable in certain situations, and so the surgical technique of choice is often arthrodesis, where the two bones are fused together to remove the joint. Key factors that affect the successful outcome of such procedures are the levels of contact and pressure across the joint during the arthrodesis compression period. This study evaluates the difference in contact area and pressures that can be expected during an external arthrodesis procedure. Comparisons are obtained for different shaped joint surfaces, namely flat or curved, and compression pin placement, namely central to the talar dome or anterior. The effect of the Achilles tendon upon this structure is also considered. The mechanical stability of these constructs was then evaluated resulting in load/deflection curves for the different situations. Contact areas and pressures were measured by installing models representing the ankle joint into a test rig specifically designed for the purpose. Pressure sensitive film was used to measure the pressure across the joint, whilst measured loads were applied using compression pins through the talar model to achieve compression. Loads were then applied to these models to simulate motion forces at the ankle, and the resulting deflections recorded. Results indicate that there is little difference in terms of joint contact area and pressure between curved and flat cut scenarios. An anterior talar pin position does, however give the best contact area for both flat and curved shapes. Mechanical stability was also influenced by pin position, with anterior pins giving the optimum resistance to motion when combined with an Achilles tendon load. Curved joint shapes gave a marked improvement in stability when tested for rotation, previously identified as the weakest and most important micromotion at the arthrodesis site. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:174 / 178
页数:5
相关论文
共 50 条
  • [31] Contact Force Decomposition Using Contact Pressure Distribution
    Kim, Hyoungkyun
    Choi, Seungmoon
    Chung, Wan Kyun
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2017, 2 (01): : 290 - 297
  • [32] High-Energy Pilon Fractures: Role of External Fixation in Acute and Definitive Treatment. What are the Indications and Technique for Primary Ankle Arthrodesis?
    Swords, Michael P.
    Weatherford, Brian
    FOOT AND ANKLE CLINICS, 2020, 25 (04) : 523 - +
  • [33] Contact analyses for anisotropic half-space coated with an anisotropic layer: Effect of the anisotropy on the pressure distribution and contact area
    Bagault, C.
    Nelias, D.
    Baietto, M. C.
    Ovaert, T. C.
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2013, 50 (05) : 743 - 754
  • [34] Evaluation of different shape-memory staple configurations against crossed screws for first metatarsophalangeal joint arthrodesis: A biomechanical study
    Willmott, H.
    Al-Wattar, Z.
    Halewood, C.
    Dunning, M.
    Amis, A.
    FOOT AND ANKLE SURGERY, 2018, 24 (03) : 259 - 263
  • [35] Ankle arthrodesis using a tibio-calcaneal external fixatorArthrodèse de la cheville par fixateur externe tibio-calacanéen
    Nikolaos A. Christodoulou
    Andreas F. Mavrogenis
    Christos Sdrenias
    Evanthia A. Mitsiokapa
    Rizos Tsaknis
    George Salagiannis
    Panayiotis J. Papagelopoulos
    European Journal of Orthopaedic Surgery & Traumatology, 2006, 16 (2) : 146 - 149
  • [36] Initial stability and stress distribution of ankle arthroscopic arthrodesis with three kinds of 2-screw configuration fixation: a finite element analysis
    Min Zhu
    Cheng-song Yuan
    Zhong-min Jin
    Yun-jiao Wang
    You-xing Shi
    Zhi-jin Yang
    Kanglai Tang
    Journal of Orthopaedic Surgery and Research, 13
  • [37] Initial stability and stress distribution of ankle arthroscopic arthrodesis with three kinds of 2-screw configuration fixation: a finite element analysis
    Zhu, Min
    Yuan, Cheng-song
    Jin, Zhong-min
    Wang, Yun-jiao
    Shi, You-xing
    Yang, Zhi-jin
    Tang, Kanglai
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [38] The value of bone SPECT/CT in evaluation of foot and ankle arthrodesis and adjacent joint secondary osteoarthritis
    Ujwal Bhure
    Hannes Grünig
    Maria del Sol Pérez Lago
    Dirk Lehnick
    Martin Wonerow
    Thiago Lima
    Thomas F. Hany
    Klaus Strobel
    European Journal of Nuclear Medicine and Molecular Imaging, 2023, 51 : 68 - 80
  • [39] The value of bone SPECT/CT in evaluation of foot and ankle arthrodesis and adjacent joint secondary osteoarthritis
    Bhure, Ujwal
    Grunig, Hannes
    Lago, Maria del Sol Perez
    Lehnick, Dirk
    Wonerow, Martin
    Lima, Thiago
    Hany, Thomas F.
    Strobel, Klaus
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 51 (01) : 68 - 80
  • [40] Ankle joint pressure change before and after subtalar joint arthrodesis in varus and valgus malalignment of the tibia
    Hu, Mu
    Xu, Xiangyang
    Mei, Jiong
    JOURNAL OF ORTHOPAEDIC SURGERY, 2022, 30 (01)