Effect of reconstruction methods and x-ray tube current-time product on nodule detection in an anthropomorphic thorax phantom: A crossed-modality JAFROC observer study

被引:2
作者
Thompson, J. D. [1 ,2 ]
Chakraborty, D. P. [3 ]
Szczepura, K. [1 ]
Tootell, A. K. [1 ]
Vamvakas, I. [4 ]
Manning, D. J. [5 ]
Hogg, P. [1 ,6 ]
机构
[1] Univ Salford, Directorate Radiog, Frederick Rd Campus, Salford M6 6PU, Greater Manches, England
[2] Univ Hosp Morecambe Bay NHS Fdn Trust, Furness Gen Hosp, Dept Radiol, Dalton Lane, Barrow In Furness LA14 4LF, England
[3] Univ Pittsburgh, Dept Radiol, FARP Bldg,Room 212,3362 Fifth Ave, Pittsburgh, PA 15213 USA
[4] Christie Hosp NHS Fdn Trust, Dept Radiol, 550 Wilmslow Rd, Manchester M20 4BX, Lancs, England
[5] Univ Lancaster, Furness Coll, Lancaster Med Sch, Fac Hlth & Med, Lancaster LA1 4YG, England
[6] Karolinska Inst, Dept Radiog, Solnavagen 1, S-17177 Solna, Sweden
关键词
CT; Iterative reconstruction; JAFROC; CNR; effective risk; ITERATIVE DOSE REDUCTION; FILTERED BACK-PROJECTION; ROW COMPUTED-TOMOGRAPHY; IMAGE-QUALITY; CHEST CT; MODEL OBSERVERS; 3D; EQUIVALENCE; TESTS; RISK;
D O I
10.1118/1.4941017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate nodule detection in an anthropomorphic chest phantom in computed tomography (CT) images reconstructed with adaptive iterative dose reduction 3D (AIDR(3D)) and filtered back projection (FBP) over a range of tube current-time product (mAs). Methods: Two phantoms were used in this study: (i) an anthropomorphic chest phantom was loaded with spherical simulated nodules of 5, 8, 10, and 12 mm in diameter and + 100, -630, and -800 Hounsfield units electron density; this would generate CT images for the observer study; (ii) a whole-body dosimetry verification phantom was used to ultimately estimate effective dose and risk according to the model of the BEIR VII committee. Both phantoms were scanned over a mAs range (10, 20, 30, and 40), while all other acquisition parameters remained constant. Images were reconstructed with both AIDR3D and FBP. For the observer study, 34 normal cases (no nodules) and 34 abnormal cases (containing 1-3 nodules, mean 1.35 +/- 0.54) were chosen. Eleven observers evaluated images from all mAs and reconstruction methods under the free-response paradigm. A crossed-modality jackknife alternative free-response operating characteristic (JAFROC) analysis method was developed for data analysis, averaging data over the two factors influencing nodule detection in this study: mAs and image reconstruction (AIDR3D or FBP). A Bonferroni correction was applied and the threshold for declaring significance was set at 0.025 to maintain the overall probability of Type I error at alpha = 0.05. Contrast-to-noise (CNR) was also measured for all nodules and evaluated by a linear least squares analysis. Results: For random-reader fixed-case crossed-modality JAFROC analysis, there was no significant difference in nodule detection between AIDR3D and FBP when data were averaged over mAs [F(1,10) = 0.08, p = 0.789]. However, when data were averaged over reconstruction methods, a significant difference was seen between multiple pairs of mAs settings [F(3,30) = 15.96, p < 0.001]. Measurements of effective dose and effective risk showed the expected linear dependence on mAs. Nodule CNR was statistically higher for simulated nodules on images reconstructed with AIDR3D (p < 0.001). Conclusions: No significant difference in nodule detection performance was demonstrated between images reconstructed with FBP and AIDR3D. mAs was found to influence nodule detection, though further work is required for dose optimization. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:1265 / 1274
页数:10
相关论文
共 51 条
[1]   MODEL OBSERVERS FOR ASSESSMENT OF IMAGE QUALITY [J].
BARRETT, HH ;
YAO, J ;
ROLLAND, JP ;
MYERS, KJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (21) :9758-9765
[2]   Multiple-reader studies, digital mammography, computer-aided diagnosis - and the Holy Grail of imaging physics (II) [J].
Beiden, SV ;
Wagner, RF ;
Campbell, G ;
Metz, CE ;
Jiang, YL ;
Chan, HP .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :619-626
[3]   MULTIPLE SIGNIFICANCE TESTS - THE BONFERRONI METHOD .10. [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1995, 310 (6973) :170-170
[4]   Visual signal detection in structured backgrounds. III. Calculation of figures of merit for model observers in statistically nonstationary backgrounds [J].
Bochud, FO ;
Abbey, CK ;
Eckstein, MP .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2000, 17 (02) :193-205
[5]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[6]   Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism [J].
Brunot, S ;
Corneloup, O ;
Latrabe, V ;
Montaudon, M ;
Laurent, F .
EUROPEAN RADIOLOGY, 2005, 15 (10) :2057-2063
[7]   The Rose model, revisited [J].
Burgess, AE .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (03) :633-646
[8]   Observer studies involving detection and localization: Modeling, analysis, and validation [J].
Chakraborty, DP ;
Berbaum, KS .
MEDICAL PHYSICS, 2004, 31 (08) :2313-2330
[9]   Assessment of a Model-Based, Iterative Reconstruction Algorithm (MBIR) Regarding Image Quality and Dose Reduction in Liver Computed Tomography [J].
Chang, Won ;
Lee, Jeong Min ;
Lee, Kyunghee ;
Yoon, Jeong Hee ;
Yu, Mi Hye ;
Han, Joon Koo ;
Choi, Byung Ihn .
INVESTIGATIVE RADIOLOGY, 2013, 48 (08) :598-606
[10]   Combining Automatic Tube Current Modulation with Adaptive Statistical Iterative Reconstruction for Low-Dose Chest CT Screening [J].
Chen, Jiang-Hong ;
Jin, Er-Hu ;
He, Wen ;
Zhao, Li-Qin .
PLOS ONE, 2014, 9 (04)