Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty

被引:126
作者
Hoenecke, Heinz R., Jr. [1 ]
Hermida, Juan C. [1 ]
Flores-Hernandez, Cesar [1 ]
D'Lima, Darryl D. [1 ]
机构
[1] Scripps Clin, Shiley Ctr Orthopaed Res & Educ, La Jolla, CA 92037 USA
关键词
Total shoulder arthroplasty; shoulder arthritis; 3-D reconstruction; scapular axis; glenoid version; TOMOGRAPHY; RETROVERSION;
D O I
10.1016/j.jse.2009.08.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background/Hypothesis: The arthritic glenoid is typically in retroversion and restoration to neutral version is recommended. While a method for measurement of glenoid version using axial computed tomography (CT) has been reported and has been widely accepted, its accuracy and reproducibility has not been established. Methods: In 33 patients scheduled for shoulder arthroplasty, glenoid version and maximum wear of the glenoid articular surface were measured with respect to the scapular body axis on 2-dimensional- (2D) CT slices as well as on 3-dimensional- (3D) reconstructed models of the same CT slices. Results: Clinical CT scans were axially aligned with the patient's torso but were almost never perpendicular to the scapular body. The average absolute error in version measured on the 2D-CT slice passing through the tip of the coracoid was 5.1 degrees (range, 0 - 16 degrees, P < .001). On high-resolution 3D-CT reconstructions, the location of maximum wear was most commonly posterior and was missed on the clinical 2D-CT slices in 52% of cases. Conclusion: Error in measuring version and depth of maximum wear can substantially affect the determination of the degree of correction necessary in arthritic glenoids. Accurately measuring glenoid version and locating the direction of maximum wear requires a full 3D-CT reconstruction and analysis. Level of Evidence: Level I; Diagnostic Study. (C) 2010 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:166 / 171
页数:6
相关论文
共 12 条
[1]   EXCESSIVE RETROVERSION OF THE GLENOID CAVITY - A CAUSE OF NONTRAUMATIC POSTERIOR INSTABILITY OF THE SHOULDER [J].
BREWER, BJ ;
WUBBEN, RC ;
CARRERA, GF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (05) :724-731
[2]   Glenoid size, inclination, and version: An anatomic study [J].
Churchill, RS ;
Brems, JJ ;
Kotschi, H .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2001, 10 (04) :327-332
[3]   Risks of loosening of a prosthetic glenoid implanted in retroversion [J].
Farron, Alain ;
Terrier, Alexandre ;
Buechler, Philippe .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (04) :521-526
[4]  
Franklin J L, 1988, J Arthroplasty, V3, P39, DOI 10.1016/S0883-5403(88)80051-2
[5]   THE USE OF COMPUTERIZED-TOMOGRAPHY IN THE MEASUREMENT OF GLENOID VERSION [J].
FRIEDMAN, RJ ;
HAWTHORNE, KB ;
GENEZ, BM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1032-1037
[6]  
HERMIDA JC, 2009, T 55 ORTHOP RES SOC, V34, P1925
[7]   Optimizing glenoid component position using three-dimensional computed tomography reconstruction [J].
Hoenecke, Heinz R., Jr. ;
Hermida, Juan C. ;
Dembitsky, Nicholas ;
Patil, Shantanu ;
D'Lima, Darryl D. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (04) :637-641
[8]   Effects of glenoid component version on humeral head displacement and joint reaction forces: An experimental study [J].
Nyffeler, Richard W. ;
Sheikh, Ralph ;
Atkinson, Todd S. ;
Jacob, Hilaire A. C. ;
Favre, Philippe ;
Gerber, Christian .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (05) :625-629
[9]   Measurement of glenoid version: Conventional radiographs versus computed tomography scans [J].
Nyffeler, RW ;
Jost, B ;
Pfirrmann, CWA ;
Gerber, C .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (05) :493-496
[10]   Projection of the glenoid center point within the glenoid vault [J].
Rispoli, Damian M. ;
Sperling, John W. ;
Athwal, George S. ;
Wenger, Doris E. ;
Cofield, Robert H. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (03) :573-578