Morphological and Thermodynamic Comparison of the Lesions Created by 4 Open-Irrigated Catheters in 2 Experimental Models

被引:29
作者
Moreno, Javier [1 ,2 ]
Quintanilla, Jorge G. [1 ,3 ]
Molina-Morua, Roberto [1 ]
Jesus Garcia-Torrent, Maria [1 ]
Jose Angulo-Hernandez, Maria [4 ]
Curiel-Llamazares, Carolina [1 ]
Ramiro-Bargueno, Julio [4 ]
Gonzalez, Pablo [1 ]
Caamano, Antonio J. [4 ]
Perez-Castellano, Nicasio [1 ]
Luis Rojo-Alvarez, Jose [4 ]
Macaya, Carlos [1 ]
Perez-Villacastin, Julian [1 ]
机构
[1] Hosp Clin San Carlos, IdISSC, Cardiovasc Inst, Opt & Thermal Mapping Lab,Arrhythmia Unit, Madrid 28040, Spain
[2] Hosp Ramon & Cajal, Dept Cardiol, Arrhythmia Unit, E-28034 Madrid, Spain
[3] Ctr Nacl Invest Cardiovasc Carlos III CNIC, Adv Dev Arrhythmia Mech & Therapy Lab, Madrid, Spain
[4] Univ Rey Juan Carlos, Dept Elect & Comp Engn, Madrid, Spain
关键词
arrhythmia; catheter ablation; lesion; radiofrequency; ventricular tachycardia; RADIOFREQUENCY ABLATION; CONTACT FORCE; SIZE; TIP;
D O I
10.1111/jce.12528
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Thermodynamic Evaluation of 4 Open-Irrigated Catheters. Introduction: New generation open-irrigated catheters aim to improve irrigation efficiency. This may change lesion patterns, challenging operators. Indeed, safety issues have recently arisen. We aimed to experimentally assess 4 open-irrigated catheters, comparing lesion size, safety, and heat transfer. Methods: The thigh lesion model was employed in 6 anesthetized pigs to assess the morphology of perpendicular and tangential lesions (n = 140) created by the newer catheters ThermoCool (R) SF, CoolFlex (TM), and Blazer (TM) Open-Irrigated, and the standard ThermoCool (R), at a constant power of 30 W (60 seconds). To evaluate the propensity for deep-tissue overheating, a set of 120 applications were performed at 50 W (180 seconds) comparing pop rates. Thermal assessment of the lesion generation process (20 W, 60 seconds, n = 32) was performed with an infrared camera on bovine ventricular tissue. Results: At 30 W, the newer catheters showed lower temperature readings compared with the ThermoCool (R). No major efficacy or safety differences were found at tangential applications; however, at perpendicular applications: (1) the SF at 17 mL/min better preserved the superficial layers and focused its maximum thermal effect deeper, but at recommended flow rates (8 mL/min) it generated the largest superficial lesions; (2) CoolFlex (TM) created smaller lesions than SF and readily induced steam pops at 50 W without temperature control; and (3) no major differences were found comparing Blazer (TM) Open-Irrigated and ThermoCool (R). Conclusions: The lower temperature readings in the newer catheters make them more prone to deliver the maximum programmed power. Under experimental conditions, the SF catheter focuses its maximum effect deeper and the CoolFlex (TM) can be more prone to induce steam pops at high power settings.
引用
收藏
页码:1391 / 1399
页数:9
相关论文
共 22 条
  • [1] [Anonymous], 2014, BLAZ OP IRR ABL CATH
  • [2] [Anonymous], 2012, BLAZ OP IRR ABL CAT
  • [3] [Anonymous], 2013, INSTR US IFU THER CO
  • [4] Comparison of ThermoCool® Surround Flow Catheter Versus ThermoCool® Catheter in Achieving Persistent Electrical Isolation of Pulmonary Veins: A Pilot Study
    Bertaglia, Emanuele
    Fassini, Gaetano
    Anselmino, Matteo
    Stabile, Giuseppe
    Grandinetti, Giuseppe
    De Simone, Antonio
    Calo, Leonardo
    Pandozi, Claudio
    Pratola, Claudio
    Zoppo, Franco
    Tondo, Claudio
    Iuliano, Assunta
    Gaita, Fiorenzo
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (03) : 269 - 273
  • [5] Biosense Webster, 2012, THERMOCOOL SF DIAGN
  • [6] Biosense Webster, 2014, URG FIELD SAF NOT TH
  • [7] Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation
    Cao, H
    Tungjitkusolmun, S
    Choy, YB
    Tsai, JZ
    Vorperian, VR
    Webster, JG
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (03) : 247 - 253
  • [8] Safety Profiles and Lesion Size of Different Radiofrequency Ablation Technologies: A Comparison of Large Tip, Open and Closed Irrigation Catheters
    Everett, Thomas H.
    Lee, Ken W.
    Wilson, Emily E.
    Guerra, Jose M.
    Varosy, Paul D.
    Olgin, Jeffrey E.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (03) : 325 - 335
  • [9] Effects of Open-Irrigated Radiofrequency Ablation Catheter Design on Lesion Formation and Complications: In Vitro Comparison of 6 Different Devices
    Guerra, Jose M.
    Jorge, Esther
    Raga, Silvia
    Galvez-Monton, Carolina
    Alonso-Martin, Concepcion
    Rodriguez-Font, Enrique
    Cinca, Juan
    Vinolas, Xavier
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (10) : 1157 - 1162
  • [10] Instructions for use. Biosense Webster, 2013, NAVISTAR THERMOCOOL