Time-resolved 3D MR velocity mapping at 3T: Improved navigator-gated assessment of vascular anatomy and blood flow

被引:316
作者
Markl, Michael
Harloff, Andreas
Bley, Thorsten A.
Zaitsev, Maxim
Jung, Bernd
Weigang, Ernst
Langer, Mathias
Hennig, Juergen
Frydrychowicz, Alex
机构
[1] Univ Hosp Freiburg, Dept Diagnost Radiol Med Phys, D-79106 Freiburg, Germany
[2] Univ Hosp Freiburg, Dept Neurol & Clin Neurophysiol, Freiburg, Germany
[3] Univ Hosp Freiburg, Dept Cardiovasc Surg, Freiburg, Germany
关键词
phase-contrast MRI; flow; velocity mapping; aorta; vascular hemodynamics;
D O I
10.1002/jmri.20871
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate an improved image acquisition and data-processing strategy for assessing aortic vascular geometry and 3D blood flow at 3T. Materials and Methods: In a study with five normal volunteers and seven patients with known aortic pathology, prospectively ECG-gated cine three-dimensional (3D) MR velocity mapping with improved navigator gating, real-time adaptive k-space ordering and dynamic adjustment of the navigator acceptance criteria was performed. In addition to morphological information and three-directional blood flow velocities, phase-contrast (PC)-MRA images were derived from the same data set, which permitted 3D isosurface rendering of vascular boundaries in combination with visualization of blood-flow patterns. Results: Analysis of navigator performance and image quality revealed improved scan efficiencies of 63.6% +/- 10.5% and temporal resolution (<50 msec) compared to previous implementations. Semiquantitative evaluation of image quality by three independent observers demonstrated excellent general image appearance with moderate blurring and minor ghosting artifacts. Results from volunteer and patient examinations illustrate the potential of the improved image acquisition and data-processing strategy for identifying normal and pathological blood-flow characteristics. Conclusion: Navigator-gated time-resolved 3D MR velocity mapping at 3T in combination with advanced data processing is a powerful tool for performing detailed assessments of global and local blood-flow characteristics in the aorta to describe or exclude vascular alterations.
引用
收藏
页码:824 / 831
页数:8
相关论文
共 32 条
  • [11] ACCURACY OF MR PHASE-CONTRAST VELOCITY-MEASUREMENTS FOR UNSTEADY-FLOW
    FRAYNE, R
    STEINMAN, DA
    ETHIER, CR
    RUTT, BK
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04): : 428 - 431
  • [12] Three dimensional flow in the human left atrium
    Fyrenius, A
    Wigström, L
    Ebbers, T
    Karlsson, M
    Engvall, J
    Bolger, AF
    [J]. HEART, 2001, 86 (04) : 448 - 455
  • [13] Asymmetric redirection of flow through the heart
    Kilner, PJ
    Yang, GZ
    Wilkes, AJ
    Mohiaddin, RH
    Firmin, DN
    Yacoub, MH
    [J]. NATURE, 2000, 404 (6779) : 759 - 761
  • [14] Visualization of flow patterns distal to aortic valve prostheses in humans using a fast approach for cine 3D velocity mapping
    Kozerke, S
    Hasenkam, JM
    Pedersen, EM
    Boesiger, P
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (05) : 690 - 698
  • [15] Flow patterns in the aortic root and the aorta studied with time-resolved, 3-dimensional, phase-contrast magnetic resonance imaging:: Implications for aortic valve-sparing surgery
    Kvitting, JPE
    Ebbers, T
    Wigström, L
    Engvall, J
    Olin, CL
    Bolger, AF
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (06) : 1602 - 1607
  • [16] Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: In vitro and in vivo validation
    Lee, VS
    Spritzer, CE
    Carroll, BA
    Pool, LG
    Bernstein, MA
    Heinle, SK
    MacFall, JR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (04) : 1125 - 1131
  • [17] Cardiovascular magnetic resonance imaging: Current and emerging applications
    Lima, JAC
    Desal, MY
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (06) : 1164 - 1171
  • [18] In vitro validation of phase-contrast flow measurements at 3 T in comparison to 1.5 T:: Precision, accuracy, and signal-to-noise ratios
    Lotz, J
    Döker, R
    Noeske, R
    Schüttert, M
    Felix, R
    Galanski, M
    Gutberlet, M
    Meyer, GP
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (05) : 604 - 610
  • [19] Time-resolved 3-dimensional velocity mapping in the thoracic aorta - Visualization of 3-directional blood flow patterns in healthy volunteers and patients
    Markl, M
    Draney, MT
    Hope, MD
    Levin, JM
    Chan, FP
    Alley, MT
    Pelc, NJ
    Herfkens, RJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (04) : 459 - 468
  • [20] Time-resolved three-dimensional phase-contrast MRI
    Markl, M
    Chan, FP
    Alley, MT
    Wedding, KL
    Draney, MT
    Elkins, CJ
    Parker, DW
    Wicker, R
    Taylor, CA
    Herfkens, RJ
    Pelc, NJ
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (04) : 499 - 506