Total hip replacement monitoring: numerical models for the acoustic emission technique

被引:9
作者
Ramachandran, Remya Ampadi [1 ,2 ,3 ]
Lee, Christine [1 ,2 ,4 ]
Zhang, Lu [5 ,6 ]
Supriya, M. H. [3 ]
Bijukumar, Divya [4 ]
Pai, P. Srinivasa [7 ]
Foucher, Kharma [8 ]
Chi, Sheng-Wei [5 ]
Ozevin, Didem [5 ]
Mathew, Mathew T. [1 ,2 ,4 ]
机构
[1] Univ Illinois, Dept Biomed Engn, Coll Engn, Chicago, IL 60612 USA
[2] Univ Illinois, Coll Med, Dept Biomed Engn, Chicago, IL 60612 USA
[3] Cochin Univ Sci & Technol, Dept Elect, Kochi, Kerala, India
[4] Univ Illinois, Coll Med, RMDR Lab, Dept Biomed Sci, Rockford, IL 61107 USA
[5] Univ Illinois, Dept Civil Mat & Environm Engn, Chicago, IL 60612 USA
[6] Guilin Univ Technol, Coll Civil Engn & Architecture, Guilin, Peoples R China
[7] NMAM Inst Technol, Dept Mech Engn, Nitte, Karnataka, India
[8] Univ Illinois, Dept Kinesiol & Nutr, Chicago, IL USA
关键词
Total hip replacements (THR); Non-invasive techniques; Acoustic emission (AE); Finite element (FE) analysis; Numerical modeling; FINITE-ELEMENT-ANALYSIS; ABRASIVE PARTICLE IMPACTS; WAVE-PROPAGATION; AE ENERGY; TISSUE; FEMUR; ATTENUATION; INTERFACE; IMPLANTS; VELOCITY;
D O I
10.1007/s11517-022-02548-6
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Any mechanical instability associated with total hip replacement (THR) excites elastic waves with different frequencies and propagates through the surrounding biological layers. Using the acoustic emission (AE) technique as a THR monitoring tool provides valuable information on structural degradations associated with these implants. However, several factors can compromise the reliability of the signals detected by AE sensors, such as attenuation of the detected signal due to the presence of biological layers in the human body between prosthesis (THR) and AE sensor. The main objective of this study is to develop a numerical model of THR that evaluates the impact of biological layer thicknesses on AE signal propagation. Adipose tissue thickness, which varies the most between patients, was modeled at two different thicknesses 40 mm and 70 mm, while the muscle and skin thicknesses were kept to a constant value. The proposed models were tested at different micromotions of 2 mu m, 15-20 mu m at modular junctions, and different frequencies of 10-60 kHz. Attenuation of signal is observed to be more with an increase in the selected boundary conditions along with an increase in distance the signals propagate through. Thereby, the numerical observations drawn on each interface helped to simulate the effect of tissue thicknesses and their impact on the attenuation of elastic wave propagation to the AE receiver sensor.
引用
收藏
页码:1497 / 1510
页数:14
相关论文
共 78 条
  • [1] Anisotropy of human muscle via non-invasive impedance measurements
    Aaron, R
    Huang, M
    Shiffman, CA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (07) : 1245 - 1262
  • [2] Abbey, 2016, STRESS FEA 3
  • [3] Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies
    Abu-Amer, Yousef
    Darwech, Isra
    Clohisy, John C.
    [J]. ARTHRITIS RESEARCH & THERAPY, 2007, 9 (Suppl 1)
  • [4] Amin V. R, 1989, Ultrasonic attenuation estimation for tissue characterization
  • [5] Stress-wave energy management through material anisotropy
    Amirkhizi, Alireza V.
    Tehranian, Aref
    Nemat-Nasser, Sia
    [J]. WAVE MOTION, 2010, 47 (08) : 519 - 536
  • [6] Ampadi R., 2020, MED BIOL ENG COMPUT, P1
  • [7] Influence of PEEK Coating on Hip Implant Stress Shielding: A Finite Element Analysis
    Anguiano-Sanchez, Jesica
    Martinez-Romero, Oscar
    Siller, Hector R.
    Diaz-Elizondo, Jose A.
    Flores-Villalba, Eduardo
    Rodriguez, Ciro A.
    [J]. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2016, 2016
  • [8] Augusta University Medical college of Georgia, 2020, RES PHYS LECT
  • [9] Propagating Stress Waves During Epithelial Expansion
    Banerjee, Shiladitya
    Utuje, Kazage J. C.
    Marchetti, M. Cristina
    [J]. PHYSICAL REVIEW LETTERS, 2015, 114 (22)
  • [10] Benoit M, 2009, IFMBE PROC, V23, P1623