Cyclic testing of two- and three-story CFS shear-walls with reinforced end studs

被引:30
作者
Wang, Xingxing [1 ]
Ye, Jihong [1 ]
机构
[1] Southeast Univ, Minist Educ, Key Lab Concrete & Prestressed Concrete Struct, Nanjing, Jiangsu, Peoples R China
关键词
Mid-rise CFS shear wall; Cyclic loading test; Concrete-filled rectangular steel tube (CFRSF) column; Opening; Simplified calculation method; PERFORMANCE; SINGLE; PANELS;
D O I
10.1016/j.jcsr.2015.12.028
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cyclic loading tests on seven cold-formed steel shear walls were performed concerning the-influence of the end stud type, stud section, interlayer action and openings. The results showed that: (1) failure modes similar to the single-story shear wall test results mainly occurred in the underlying wall; (2) two-story specimens with an aspect ratio of less than 2.0 had shear type failures, whereas the failure mechanism of three-story specimens with an aspect ratio larger than 3.0 tended to be bending failure; (3) both shear strength and non-deformability were notably enhanced by adopting reinforced end studs, and the specimens exhibited better energy-dissipating capacity after their yield limit; (4) when the web depth of end columns was enlarged from 89 mm to 140 mm, for a fully sheathed specimen, the elastic stiffness of the lower story was improved by nearly 41.5%, while there was no meaningful reduction in the non-deformability of the upper story if the opening area ratio was 20.8% at most; (5) due to the second story, the base shear of the two-story specimen was less than the shear capacity of the corresponding single-story shear wall; and (6) the decreased percentages of the shear strength for specimens with similar opening area ratios were nearly the same, which is irrelevant to the stud section. Based on a bearing mechanism analysis of the perforated shear wall, a simplified method was proposed to predict the base shear for a mid-rise shear wall with a relative error of 1.5% between the calculated and test results. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:13 / 28
页数:16
相关论文
共 18 条
[1]  
[Anonymous], 2012, GB 50009-2012
[2]   Behavior of cold-formed steel wall panels under monotonic horizontal loading [J].
Baran, Eray ;
Alica, Cagatay .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 79 :1-8
[3]   Full-scale fire experiments on load-bearing cold-formed steel walls lined with different panels [J].
Chen, Wei ;
Ye, Jihong ;
Bai, Yu ;
Zhao, Xiao-Ling .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 79 :242-254
[4]  
Cheng Y., 2014, STRUCT C ASCE, P2721
[5]  
ECCS, 1985, Recommended testing procedure for assessing the behaviour of structural steel elements under cyclic loads
[6]   Experimental tests on typical screw connections for cold-formed steel housing [J].
Fiorino, L. ;
Della Corte, G. ;
Landolfo, R. .
ENGINEERING STRUCTURES, 2007, 29 (08) :1761-1773
[7]  
Fiorino L., 2008, P 19 INT SPEC C COLD, P603
[8]   Performance of wall-stud cold-formed shear panels under monotonic and cyclic loading Part I:: Experimental research [J].
Fülöp, LA ;
Dubina, D .
THIN-WALLED STRUCTURES, 2004, 42 (02) :321-338
[9]   Concrete-filled thin-walled steel SHS and RHS beam-columns subjected to cyclic loading [J].
Han, LH ;
Yang, YF ;
Tao, Z .
THIN-WALLED STRUCTURES, 2003, 41 (09) :801-833
[10]   Experimental work on single and double-sided steel sheathed cold-formed steel shear walls for seismic actions [J].
Mohebbi, Saeed ;
Mirghaderi, Rasoul ;
Farahbod, Farhang ;
Sabbagh, Alireza Bagheri .
THIN-WALLED STRUCTURES, 2015, 91 :50-62