Vertebral morphometry: Repeat scan precision using the lunar Expert-XL and the hologic 4500A. A study for the 'WISDOM' RCT of hormone replacement therapy

被引:16
作者
Crabtree, N
Wright, J
Walgrove, A
Rea, J
Hanratty, L
Lunt, M
Fogelman, I
Palmer, R
Vickers, M
Compston, JE
Reeve, J
机构
[1] Univ Cambridge, Addenbrookes Hosp, Dept Med, Bone Res Grp,Wellcome, Cambridge CB2 2QQ, England
[2] MRC, Epidemiol & Med Care Unit, Wolfson Inst Prevent Med, London, England
[3] United Med & Dent Sch, Guys Hosp Trust, Bone Dens Unit, London, England
[4] Univ Cambridge, Inst Publ Hlth, Cambridge, England
[5] Birmingham Heartlands & Solihull NHS Trust, Dept Rheumatol, Birmingham, W Midlands, England
关键词
dual X-ray absorptiometry; osteoporosis prevention; radiographic vertebral morphometry; randomised controlled trial; statistical power;
D O I
10.1007/s001980070098
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
On radiation safety grounds there is concern about the morbidity attributable to routine radiographs of the spine for the identification of new fractures in large-scale trials of fracture prevention. However, the role of the potentially safer low-radiation-dose technique of vertebral morphometry performed by third generation dual-energy X-ray absorptiometry equipment requires evaluation for use in clinical trials. We have therefore investigated the short-term inter-scan imprecision as well as the imprecision attributable to different-day analyses by the same operator and differences in analyses by different operators. The volunteer subjects were participants in a pilot study for a randomized controlled trial of hormone replacement therapy (Women's International Study of long Duration Oestrogen after Menopause, WISDOM), Each subject had two morphometric X-ray analysis scans separated by 2-4 weeks. Exclusions were women with densitometrically defined osteoporosis, as defined by the WHO criterion, and women with a body mass index exceeding 30.9 kg/m(2). On average, the women were 58.7 years of age and had bone mineral density values in the lumbar spine which were about 0.7 SD units higher than a reference US female age-matched population. Scans were assessed from vertebrae T7 through L4. In the study there were no clinically significant differences in performance between the Hologic QDR 4500A and the Lunar Expert XL equipment. Between-scan imprecision was significantly worse than imprecision attributable to reanalysis of the same scan by a different operator or the same operator after an interval. Vertebral level had an effect on measurement uncertainty, especially at the level of the diaphragm and at T7. Coefficients of variation, expressed as percentages of mean values, were better for absolute height measurements than for height ratios, ranging from 1.75% to 3.40% for the three heights measured on three separate machines and from 2.34% to 4.11% for the two height ratios. These results compared favorably with the equivalent figures from a parallel study of morphometry precision undertaken using standard lateral radiographs of the thoracic and lumbar spine (3.1-3.6% and 3.8-3.9%, respectively). We conclude that in trials of prevention therapy in women (or men) selected for not having osteoporosis, low-dose vertebral morphometry using the Hologic 4500A, the Lunar Expert XL or similar equipment is preferable on safety grounds to the classical technique based on standard radiographs, although conventional radiology may still be required in those with prevalent or incident deformities to exclude causes other than osteoporosis. The place of this low-dose technique in trials performed on patients with osteoporosis requires further study.
引用
收藏
页码:537 / 543
页数:7
相关论文
共 14 条
[1]  
BLACK DM, 1995, J BONE MINER RES, V10, P890
[2]  
EASTELL R, 1991, J BONE MINER RES, V6, P207
[3]   ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270
[4]  
Huang C, 1996, J BONE MINER RES, V11, P1026
[5]   A preliminary evaluation of the Lunar Expert-XL for bone densitometry and vertebral morphometry [J].
Lang, T ;
Takada, M ;
Gee, R ;
Wu, C ;
Li, J ;
HayashiClark, C ;
Schoen, S ;
March, V ;
Genant, HK .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (01) :136-143
[6]   THE ASSESSMENT OF VERTEBRAL DEFORMITY - A METHOD FOR USE IN POPULATION STUDIES AND CLINICAL-TRIALS [J].
MCCLOSKEY, EV ;
SPECTOR, TD ;
EYRES, KS ;
FERN, ED ;
OROURKE, N ;
VASIKARAN, S ;
KANIS, JA .
OSTEOPOROSIS INTERNATIONAL, 1993, 3 (03) :138-147
[7]   Differential diagnosis of vertebral osteoporosis: Reliability of radiological classification criteria [J].
Raspe, H ;
Raspe, A ;
Holzmann, M ;
Leidig, G ;
Scheidt-Nave, C ;
Felsenberg, D ;
Banzer, D ;
Matthis, C .
MEDIZINISCHE KLINIK, 1998, 93 (Suppl 2) :34-40
[8]   Morphometric X-ray absorptiometry and morphometric radiography of the spine: A comparison of analysis precision in normal and osteoporotic subjects [J].
Rea, JA ;
Chen, MB ;
Li, J ;
Potts, E ;
Fan, B ;
Blake, GM ;
Steiger, P ;
Smith, IG ;
Genant, HK ;
Fogelman, I .
OSTEOPOROSIS INTERNATIONAL, 1999, 9 (06) :536-544
[9]   PREEXISTING FRACTURES AND BONE MASS PREDICT VERTEBRAL FRACTURE INCIDENCE IN WOMEN [J].
ROSS, PD ;
DAVIS, JW ;
EPSTEIN, RS ;
WASNICH, RD .
ANNALS OF INTERNAL MEDICINE, 1991, 114 (11) :919-923
[10]   PREDICTING VERTEBRAL FRACTURE INCIDENCE FROM PREVALENT FRACTURES AND BONE-DENSITY AMONG NON-BLACK, OSTEOPOROTIC WOMEN [J].
ROSS, PD ;
GENANT, HK ;
DAVIS, JW ;
MILLER, PD ;
WASNICH, RD .
OSTEOPOROSIS INTERNATIONAL, 1993, 3 (03) :120-126