Considering Failure Probability for Back-up Relay in Determination of the Optimum Routine Test Interval in Protective System Using Markov Model

被引:0
作者
Damchi, Y. [1 ]
Sadeh, J. [2 ]
机构
[1] Ferdowsi Univ Mashhad, Mashhad, Iran
[2] Ferdowsi Univ Mashhad, Dept Elect Engn, Mashhad, Iran
来源
2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8 | 2009年
关键词
Protection of power systems; Reliability; Routine Test; Self Checking; Back-up relay;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to enhance both dependability and security which are two aspects of relaying system, self-checking and monitoring facilities are usually considered along with routine test. In practice, back-up relay can has mal trip when not required and may fail to trip when required which may cause power system blackout due to cascading failure. Generally, this situation is not taken into account in the previous studies. Therefore in this paper, a Markov model is proposed for reliability analysis when back-up relay is not perfectly reliable, Simulation results demonstrate that if back-up relay is not perfectly reliable, the optimum routine test interval and reliability indices decrease. In the proposed Markov model, it is assumed that there is only self-checking facility with routine test and monitoring test is not considered for simplification
引用
收藏
页码:3639 / +
页数:2
相关论文
共 9 条
  • [1] An improved reliability model for redundant protective systems - Markov models
    Anderson, PM
    Chintaluri, GM
    Magbuhat, SM
    Ghajar, RF
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 1997, 12 (02) : 573 - 578
  • [2] [Anonymous], 1994, RELIABILITY EVALUATI
  • [3] Late Oligocene to early Miocene geochronology and paleoceanography from the subantarctic South Atlantic
    Billups, K
    Channell, JET
    Zachos, J
    [J]. PALEOCEANOGRAPHY, 2002, 17 (01):
  • [4] KUMRA JJ, 1995, IEEE T POWER DELIVER, V10, P659
  • [5] The influence of protection system failures and preventive maintenance on protection systems in distribution systems
    Meeuwsen, JJ
    Kling, WL
    Ploem, WAGA
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (01) : 125 - 133
  • [6] Seyedi H., 2006, P IEEE POW IND C, P5
  • [7] Proposed statistical performance measures for microprocessor-based transmission-line protective relays .1. Explanation of the statistics
    Udren, EA
    Zipp, JA
    Michel, GL
    Mustaphi, KK
    Nilsson, SL
    Phadke, AG
    Ramaswami, R
    Rockefeller, GD
    Sachdev, MS
    Strang, WM
    Thorp, JS
    Tziouvaras, DA
    Varneckas, V
    Wanger, CL
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (01) : 134 - 143
  • [8] *W SYST COUNC, 1996, W SYST COUNC FIN REP
  • [9] Yu XB, 2002, 2002 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, P963, DOI 10.1109/PESS.2002.1043514