Comparison of a new image-guided system versus partial coherence interferometry, Scheimpflug imaging, and optical low-coherence reflectometry devices: Keratometry and repeatability

被引:17
作者
Mueller, Andreas [1 ]
Thomas, Bettina C. [1 ]
Auffarth, Gerd U. [1 ]
Holzer, Mike P. [1 ]
机构
[1] Heidelberg Univ, Int Vis Correct Res Ctr, Dept Ophthalmol, D-69120 Heidelberg, Germany
关键词
INTRAOCULAR-LENS IMPLANTATION; CATARACT-SURGERY; REFRACTIVE OUTCOMES; AGREEMENT; BIOMETRY; ULTRASOUND; IOLMASTER; PREDICTION; ACCURACY; MYOPES;
D O I
10.1016/j.jcrs.2016.01.042
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the repeatability of keratometry of the Verion image-guided system and to compare the keratometry (K) values with those of established biometric devices. SETTING: International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. DESIGN: Prospective case series. METHODS: One randomly chosen eye of volunteers was examined with partial coherence interferometry (PCI) (IOLMaster 500), optical low-coherence reflectometry (OLCR) (Lenstar LS 900), a Scheimpflug device (Pentacam HR), and the new image-guided system by the same examiner. None of the eyes had ocular pathology. Three consecutive measurements were performed with the image-guided system and 1 with the other devices. The flat, steep, and average corneal radii; steep axis; and white-to-white (WTW) distance were analyzed and compared. RESULTS: One hundred twenty-three eyes of 123 volunteers (mean age 37.9 years +/- 16.2 [SD]) had valid measurements for all examinations and were available for analysis. The image-guided system measured statistically significant smaller flat, steep, and average corneal radii than the Scheimpflug device, statistically significant larger flat and average corneal radii than the PCI device, and no statistically significant different values than the OLCR device. The measured steep axis did not differ significantly in any comparison. The WTW measurements were significantly higher than those of all other devices. The analysis of repeatability of the image-guided system showed high intraclass correlation coefficients (range 0.919 to 0.997). CONCLUSIONS: The new image-guided system had high repeatability for K, steep axis, and WTW measurements. The WTW measurements with the image-guided system were significantly higher than those using the other devices.
引用
收藏
页码:672 / 678
页数:7
相关论文
共 22 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Risk management lessons from a review of 168 cataract surgery claims (Reprinted from OMIC Digest, vol 7, pg 4-8, 1997) [J].
Brick, DC .
SURVEY OF OPHTHALMOLOGY, 1999, 43 (04) :356-360
[3]   Scheimpflug-Placido topographer and optical low-coherence reflectometry biometer: Repeatability and agreement [J].
Chen, Wuhe ;
McAlinden, Colm ;
Pesudovs, Konrad ;
Wang, Qinmei ;
Lu, Fan ;
Feng, Yifan ;
Chen, Jie ;
Huang, Jinhai .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (09) :1626-1632
[4]   Keratometry obtained by corneal mapping versus the IOLMaster in the prediction of postoperative refraction in routine cataract surgery [J].
Dulku, Simon ;
Smith, Henry B. ;
Antcliff, Richard J. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 (01) :12-18
[5]   IOLMaster biometry: refractive results of 100 consecutive cases [J].
Eleftheriadis, H .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (08) :960-963
[6]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773
[7]   Agreement study of keratometric values measured by Biograph/LENSTAR, auto-kerato-refractometer and Pentacam: Decision for IOL calculation [J].
Hashemi, Hassan ;
Asgari, Soheila ;
Miraftab, Mohammad ;
Emamian, Mohammad Hassan ;
Shariati, Mohammad ;
Fotouhi, Akbar .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2014, 97 (05) :450-455
[8]  
Holladay JT., 1999, Houston TX, Holladay LASIK Institute
[9]   Agreement analysis of LENSTAR with other techniques of biometry [J].
Jasvinder, S. ;
Khang, T. F. ;
Sarinder, K. K. S. ;
Loo, V. P. ;
Subrayan, V. .
EYE, 2011, 25 (06) :717-724
[10]   Refractive outcomes after cataract surgery: Scheimpflug keratometry versus standard automated keratometry in virgin corneas [J].
Lam, Sheridan ;
Gupta, Balaji K. ;
Hahn, John M. ;
Manastersky, Natalka A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11) :1984-1987