Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments

被引:136
作者
Ullmann, CJ
Peters, OA
机构
[1] Univ Zurich, Dept Prevent Dent, Div Endodontol Periodontol & Cariol, CH-8028 Zurich, Switzerland
[2] Univ Calif San Francisco, Dept Prevent & Restorat Dent Sci, Endodont Div, San Francisco, CA 94143 USA
关键词
D O I
10.1097/01.don.0000137641.87125.8f
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of the present study was to evaluate static fracture loads of ProTaper Nickel-Titanium instruments that had been subjected to various degrees of cyclic fatigue, Torque and angle at failure of new instruments and instruments that had been stressed to 30, 60, or 90% of their cyclic fatigue rotations in a simulated canal (90degrees and 5 mm radius) were tested according to ISO 3630-1. With unused ProTaper instruments, resistance to cyclic fatigue decreased with diameter increase and ranged from 158 to 450 rotations. Torque at failure ranged from 0.5 to 2.1 Ncm and showed a strong linear relationship to instrument diameter (r(2) = 0.9) while angle at failure was weakly related to diameter (r(2) = 0.46). Cyclic prestressing significantly reduced torsional resistance in finishing files, while shaping files were largely unaffected. in conclusion, build-up of tension within NiTi rotary instruments depends on instrument diameter. Clinically, larger instruments that have been subjected to some cyclic fatigue should be used with great care or discarded.
引用
收藏
页码:183 / 186
页数:4
相关论文
共 19 条
[1]   Incidence of rotary ProFile instrument fracture and the potential for bypassing in vivo [J].
Al-Fouzan, KS .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (12) :864-867
[2]   The 'Lightspeed' preparation technique evaluated by Swiss clinicians after attending continuing education courses [J].
Barbakow, F ;
Lutz, F .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :46-50
[3]   Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile [J].
Berutti, E ;
Chiandussi, G ;
Gaviglio, I ;
Ibba, A .
JOURNAL OF ENDODONTICS, 2003, 29 (01) :15-19
[4]   RELATIONSHIP OF BROKEN ROOT CANAL INSTRUMENTS TO ENDODONTIC CASE PROGNOSIS - A CLINICAL INVESTIGATION [J].
CRUMP, MC ;
NATKIN, E .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1970, 80 (06) :1341-+
[5]   Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors [J].
Gambarini, G .
JOURNAL OF ENDODONTICS, 2001, 27 (12) :772-774
[6]   Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments [J].
Haïkel, Y ;
Serfaty, R ;
Bateman, G ;
Senger, B ;
Allemann, C .
JOURNAL OF ENDODONTICS, 1999, 25 (06) :434-440
[7]  
*INT ORG STAND, 1992, DENT ROOT CAN INST 1
[8]   TORSIONAL AND METALLURGICAL PROPERTIES OF ROTARY ENDODONTIC INSTRUMENTS .2. STAINLESS-STEEL GATES GLIDDEN DRILLS [J].
LUEBKE, NH ;
BRANTLEY, WA .
JOURNAL OF ENDODONTICS, 1991, 17 (07) :319-323
[9]   NITI FATIGUE BEHAVIOR [J].
MCNICHOLS, JL ;
BROOKES, PC ;
CORY, JS .
JOURNAL OF APPLIED PHYSICS, 1981, 52 (12) :7442-7443
[10]   Influence of operator experience on canal preparation time when using the rotary Ni-Ti ProFile system in simulated curved canals [J].
Mesgouez, C ;
Rilliard, F ;
Matossian, L ;
Nassiri, K ;
Mandel, E .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (03) :161-165