Intravoxel Incoherent Motion Diffusion-Weighted MRI of the Abdomen: The Effect of Fitting Algorithms on the Accuracy and Reliability of the Parameters

被引:52
|
作者
Park, Hyo Jung [1 ,2 ]
Sung, Yu Sub [1 ,2 ]
Lee, Seung Soo [1 ,2 ]
Lee, Yedaun [3 ]
Cheong, Hyunhee [1 ,2 ]
Kim, Yeong Jae [1 ,2 ]
Lee, Moon-gyu [1 ,2 ]
机构
[1] Univ Ulsan, Dept Radiol, Coll Med, Asan Med Ctr, 88 Olympic Ro 43 Gil, Seoul 138736, South Korea
[2] Univ Ulsan, Res Inst Radiol, Coll Med, Asan Med Ctr, 88 Olymp Ro 43 Gil, Seoul 138736, South Korea
[3] Inje Univ, Coll Med, Haeundae Paik Hosp, Dept Radiol, Busan, South Korea
基金
新加坡国家研究基金会;
关键词
PANCREATIC NEUROENDOCRINE TUMORS; FATTY LIVER-DISEASE; HISTOLOGIC GRADE; BREAST-CANCER; OPTIMIZATION; COEFFICIENT; REPRODUCIBILITY; REPEATABILITY; VARIABILITY; METASTASES;
D O I
10.1002/jmri.25535
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the influence of fitting methods on the accuracy and reliability of intravoxel incoherent motion (IVIM) parameters, with a particular emphasis on the constraint function. Materials and Methods Diffusion-weighted (DW) imaging data were analyzed using IVIM-based full-fitting (simultaneous fit of all parameters) and segmented-fitting (step-by-step fit of each parameter), each with and without the constraint function, to estimate the molecular diffusion coefficient (D-slow), perfusion fraction (f), and flow-related diffusion coefficient (D-fast). Computational simulations were performed at variable signal-to-noise ratios to evaluate the relative error (RE) and coefficient of variation (CV) of the estimated IVIM parameters. DW imaging of the abdomen was performed twice at 1.5 Tesla using nine b-values (0-900 s/mm(2)) in 12 health volunteers (6 men and 6 women; mean age: 30 years). The measurement repeatability of IVIM parameters in the liver and the pancreas was evaluated using the within-subject coefficient of variation (wCV). ResultsIn simulations, full-fitting without the constraint function yielded the largest RE (P<0.001 for D-slow and f; P < 0.044 for D-fast) and CV (P < 0.033 for D-slow and f; P < 0.473 for D-fast) for IVIM parameters among all four algorithms. In volunteer imaging, full-fitting without the constraint function also resulted in the poorest repeatability for D-slow (wCV, 17.12%-65.45%) and f (wCV, 19.35%-42.84%) in the liver and pancreas, while the other algorithms had similar repeatability values (wCV, 4.05%-11.99% for D-slow and 9.65%-18.66% for f). Measurement repeatability of D-fast (wCV, 29.52%-85.01%) was the poorest among the IVIM parameters. Conclusion For accurate and reliable measurement of IVIM parameters, segmented fitting or full-fitting with the constraint function should be used for IVIM-based analysis of DW imaging.
引用
收藏
页码:1637 / 1647
页数:11
相关论文
共 50 条
  • [1] An In Vivo Verification of the Intravoxel Incoherent Motion Effect in Diffusion-Weighted Imaging of the Abdomen
    Lemke, Andreas
    Laun, Frederik B.
    Simon, Dirk
    Stieltjes, Bram
    Schad, Lothar R.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (06) : 1580 - 1585
  • [2] Evaluation of Hepatic Tumors Using Intravoxel Incoherent Motion Diffusion-Weighted MRI
    Wang, Mingjie
    Li, Xudan
    Zou, Jianxun
    Chen, Xugao
    Chen, Shuyan
    Xiang, Wanqing
    MEDICAL SCIENCE MONITOR, 2016, 22 : 702 - 709
  • [3] Reliable estimation of brain intravoxel incoherent motion parameters using denoised diffusion-weighted MRI
    Huang, Hsuan-Ming
    NMR IN BIOMEDICINE, 2020, 33 (04)
  • [4] MRI-based estimation of liver function by intravoxel incoherent motion diffusion-weighted imaging
    Zhang, Jing
    Guo, Yihao
    Tan, Xiangliang
    Zheng, Zeyu
    He, Mengqi
    Xu, Jun
    Mei, Yingjie
    Zhang, Jiajun
    Zhao, Xixi
    Wang, Chunhong
    Feng, Yanqiu
    Chan, Queenie
    Wu, Yuankui
    Xu, Yikai
    MAGNETIC RESONANCE IMAGING, 2016, 34 (08) : 1220 - 1225
  • [5] Intravoxel incoherent motion diffusion-weighted MRI for predicting response to neoadjuvant chemotherapy in breast cancer
    Kim, Yunju
    Kim, Sung Hun
    Lee, Hye Won
    Song, Byung Joo
    Kang, Bong Joo
    Lee, Ahwon
    Nam, Yoonho
    MAGNETIC RESONANCE IMAGING, 2018, 48 : 27 - 33
  • [6] Application of intravoxel incoherent motion diffusion-weighted imaging in hepatocellular carcinoma
    Zhou, Yi
    Zheng, Jing
    Yang, Cui
    Peng, Juan
    Liu, Ning
    Yang, Lin
    Zhang, Xiao-Ming
    WORLD JOURNAL OF GASTROENTEROLOGY, 2022, 28 (27) : 3334 - 3345
  • [7] Reproducibility of Histogram and Texture Parameters Derived from Intravoxel Incoherent Motion Diffusion-weighted MRI of FN13762 Rat Breast Carcinomas
    Song, Yong Sub
    Park, Chang Min
    Lee, Sang Min
    Park, Sang Joon
    Cho, Hye Rim
    Choi, Seung Hong
    Lee, Jeong Min
    Kiefer, Berthold
    Goo, Jin Mo
    ANTICANCER RESEARCH, 2014, 34 (05) : 2135 - 2144
  • [8] Reproducibility of radiomics features derived from intravoxel incoherent motion diffusion-weighted MRI of cervical cancer
    Chen, Hao
    He, Yaoyao
    Zhao, Cecheng
    Zheng, Lili
    Pan, Ning
    Qiu, Jianfeng
    Zhang, Zhaoxi
    Niu, Xiaohui
    Yuan, Zilong
    ACTA RADIOLOGICA, 2021, 62 (05) : 679 - 686
  • [9] Intravoxel incoherent motion diffusion-weighted MRI in patients with breast cancer: Correlation with tumor stroma characteristics
    Yuan, Li
    Wang, Zhengping
    Chen, Feng
    Qin, Xin
    Li, Changqing
    Zhao, Yingman
    Yan, Chenggong
    Wu, Yuankui
    Hao, Peng
    Xu, Yikai
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 120
  • [10] Intravoxel Incoherent Motion Diffusion-weighted MR Imaging of the Liver: Effect of Triggering Methods on Regional Variability and Measurement Repeatability of Quantitative Parameters
    Lee, Yedaun
    Lee, Seung Soo
    Kim, Namkug
    Kim, Eunki
    Kim, Yeong Jae
    Yun, Sung-Cheol
    Kuehn, Bernd
    Kim, In Seong
    Park, Seong Ho
    Kim, So Yeon
    Lee, Moon-Gyu
    RADIOLOGY, 2015, 274 (02) : 405 - 415