Are Acetabular Component Alignment Guides for Total Hip Arthroplasty Accurate?

被引:21
作者
Minoda, Yukihide [1 ,2 ]
Ohzono, Kenji [2 ]
Aihara, Masaharu [2 ]
Umeda, Naoya [2 ]
Tomita, Masuhiro [2 ]
Hayakawa, Keiko [2 ]
机构
[1] Osaka City Univ, Grad Sch Med, Dept Orthopaed Surg, Abeno Ku, Osaka 5458585, Japan
[2] Kansai Rosai Hosp, Dept Orthopaed Surg, Osaka, Hyogo, Japan
关键词
acetabular component orientation; alignment guide; total hip arthroplasty; POLYETHYLENE WEAR; MOTION; ORIENTATION; POSITION;
D O I
10.1016/j.arth.2009.07.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The acetabular component orientation of total hip arthroplasty is of critical importance to the clinical results. Although navigation systems have recently been introduced, acetabular component alignment guides are still used in most of ordinary hospitals. However, the accuracy of alignment guides themselves has not been evaluated. Fifteen types of alignment guide were examined. In all the alignment guides, the angles actually indicated and those stated by manufacturers were different. Our results showed that usage of modern alignment guides inherently misleads anteversion into decrease by a mean of 6 degrees (maximum, 12 degrees) and inclination into increase by a mean of 2 degrees (maximum: 4 degrees). Such setting of alignment guides could be one of the factors of error in acetabular component orientation.
引用
收藏
页码:986 / 989
页数:4
相关论文
共 13 条
[1]   Intraoperative pelvic motion in total hip arthroplasty [J].
Asayama, I ;
Akiyoshi, Y ;
Naito, M ;
Ezoe, M .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :992-997
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[4]   Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364
[5]   Accuracy of intraoperative assessment of acetabular prosthesis placement [J].
Hassan, DM ;
Johnston, GHF ;
Dust, WNC ;
Watson, G ;
Dolovich, AT .
JOURNAL OF ARTHROPLASTY, 1998, 13 (01) :80-84
[6]  
Jaramaz B, 1998, CLIN ORTHOP RELAT R, V355, P8
[7]   Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration [J].
Kennedy, JG ;
Rogers, WB ;
Soffe, KE ;
Sullivan, RJ ;
Griffen, DG ;
Sheehan, LJ .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :530-534
[8]   DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES [J].
LEWINNEK, GE ;
LEWIS, JL ;
TARR, R ;
COMPERE, CL ;
ZIMMERMAN, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) :217-220
[9]   Acetabular component orientation in 834 total hip arthroplasties using a manual technique [J].
Minoda, Yukihide ;
Kadowaki, Toru ;
Kim, Mitsunari .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (445) :186-191
[10]   THE DEFINITION AND MEASUREMENT OF ACETABULAR ORIENTATION [J].
MURRAY, DW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :228-232