Analysis of the PMMA and cornea temperature rise during excimer laser ablation

被引:16
作者
Arba-Mosquera, Samuel [1 ,2 ]
Shraiki, Mario [2 ,3 ,4 ]
机构
[1] Univ Valladolid, Inst Oftalmobiol Aplicada, Grp Invest Cirugia Refract & Calidad Visin, E-47005 Valladolid, Spain
[2] SCHWIND Eye Tech Solut, D-63801 Kleinostheim, Germany
[3] Univ Appl Sci Darmstadt, Darmstadt, Germany
[4] Univ Wisconsin Platteville, Platteville, WI USA
关键词
cornea; PMMA; temperature; excimer; laser; ablation; IN-SITU KERATOMILEUSIS; HIGH-REPETITION-RATE; PHOTOREFRACTIVE KERATECTOMY; REFRACTIVE SURGERY; SPHERICAL-ABERRATION; SURFACE-TEMPERATURE; NONNORMAL INCIDENCE; REFLECTION LOSSES; CENTRAL ISLANDS; SMOOTHNESS;
D O I
10.1080/09500341003672072
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A general method to analyze the ablation temperature for different materials (in particular in the human cornea and poly-methyl-methacrylate (PMMA)) is provided. The model is comprehensive and provides directly laser beam characteristics and ablative spot properties. The model further provides a method to convert the temperature rise during ablation observed in PMMA to equivalent temperature rises in the cornea. The proposed model can be used for calibration, verification and validation purposes of laser systems used for ablation processes at relatively low cost and would directly improve the quality of results.
引用
收藏
页码:400 / 407
页数:8
相关论文
共 50 条
[1]   Changes in corneal asphericity after laser refractive surgery, including reflection losses and nonnormal incidence upon the anterior cornea [J].
Anera, RG ;
Jiménez, JR ;
del Barco, LJ ;
Hita, E .
OPTICS LETTERS, 2003, 28 (06) :417-419
[2]  
[Anonymous], 1701, Philos. T, P824
[3]  
Anschutz T, 1999, J REFRACT SURG, V15, pS252
[4]   Geometrical analysis of the loss of ablation efficiency at non-normal incidence [J].
Arba-Mosquera, Samuel ;
de Ortueta, Diego .
OPTICS EXPRESS, 2008, 16 (06) :3877-3895
[5]  
Argento C, 2001, J REFRACT SURG, V17, P43
[6]   EXCIMER LASER-SURGERY OF THE CORNEA - QUALITATIVE AND QUANTITATIVE ASPECTS OF PHOTOABLATION ACCORDING TO THE ENERGY DENSITY [J].
ARONROSA, DS ;
BOULNOY, JL ;
CARRE, F ;
DELACOUR, J ;
GROSS, M ;
LACOUR, M ;
OLIVO, JC ;
TIMSIT, JC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1986, 12 (01) :27-33
[7]   PMMA model of steep central islands induced by excimer laser photorefractive keratectomy [J].
Assouline, M ;
Moossavi, J ;
Muller-Steinwachs, M ;
Cohen-Sabban, J ;
Thompson, HW ;
Pouliquen, Y .
SURVEY OF OPHTHALMOLOGY, 1997, 42 :S35-S51
[8]   SIDE-EFFECTS IN EXCIMER CORNEAL SURGERY - CORNEAL THERMAL-GRADIENTS [J].
BENDE, T ;
SEILER, T ;
WOLLENSAK, J .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1988, 226 (03) :277-280
[9]  
Betney S, 1997, CORNEA, V16, P158
[10]   Laser heating and ablation at high repetition rate in thermal confinement regime [J].
Brygo, Francois ;
Semerok, A. ;
Oltra, R. ;
Weulersse, J. -M. ;
Fomichev, S. .