High efficiency control strategy in a wind energy conversion system with doubly fed induction generator

被引:22
作者
Karakasis, Nektarios E. [1 ]
Mademlis, Christos A. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Sch Elect & Comp Engn, Thessaloniki 54124, Greece
关键词
Wind system; Wind energy; High efficiency; Doubly fed induction generator; Loss reduction; POWER-CONTROL; DFIG; MODE; OPTIMIZATION; OPERATION; TURBINE; VOLTAGE;
D O I
10.1016/j.renene.2018.03.020
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a high efficiency control strategy for a wind energy conversion system (WECS) with doubly fed induction generator (DFIG). The proposed control scheme provides power loss reduction for the DFIG and maximum power point tracking (MPPT) for the wind turbine. Therefore, increased electric energy production from the same wind energy potential can be attained. Moreover, the cut-in wind speed is reduced and thereby, extension of the exploitable wind speed region is accomplished. The high efficiency in the DFIG is attained through the stator frequency and magnetic-flux weakening control, and the maximum harvesting in the turbine is accomplished by properly controlling the turbine speed. The proposed control system can be easily implemented, since the controller parameters are determined experimentally and thus, the knowledge of the wind system model is not required. Moreover, for the implementation of the proposed control scheme, a converter system of low power requirements is used, as holds in the conventional system, and thus, this advantage of the WECS with DFIG against other electrical generator types is still valid. The efficiency improvement of the proposed control scheme has been experimentally validated in a laboratory low power scaling emulation WECS with DFIG. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:974 / 984
页数:11
相关论文
共 30 条
[1]   Grid synchronisation enhancement of a wind driven DFIG using adaptive sliding mode control [J].
Abdelbaset, Adel ;
El-Sayed, Abou-Hashema M. ;
Abozeid, Alaa Eldin H. .
IET RENEWABLE POWER GENERATION, 2017, 11 (05) :688-695
[2]  
Abo-Khalil AG, 2007, IEEE IND ELEC, P1109
[3]  
Balogun A, 2013, IEEE IND ELEC, P1601, DOI 10.1109/IECON.2013.6699372
[4]  
Bianchi F.D, 2007, ADV IND CON
[5]   An Analytical Approach to Maximum Power Tracking and Loss Minimization of a Doubly Fed Induction Generator Considering Core Loss [J].
Chen, Bo-An ;
Lu, Tien-Kei ;
Hsu, Yuan-Yih ;
Chen, Woei-Luen ;
Lee, Zheng-Cong .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (02) :449-456
[6]   Collaborative Control of DFIG System During Network Unbalance Using Reduced-Order Generalized Integrators [J].
Cheng, Peng ;
Nian, Heng .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (02) :453-464
[7]   Analytical and Multiphysics Approach to the Optimal Design of a 10-MW DFIG for Direct-Drive Wind Turbines [J].
Colli, Vincenzo Delli ;
Marignetti, Fabrizio ;
Attaianese, Ciro .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (07) :2791-2799
[8]   INDUCTION-MOTOR EFFICIENCY TEST METHODS [J].
CUMMINGS, PG ;
BOWERS, WD ;
MARTINY, WJ .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1981, 17 (03) :253-272
[9]  
David N, 2014, 2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), P189, DOI 10.1109/ICELMACH.2014.6960179
[10]   Dynamic modeling of doubly fed induction generator wind turbines [J].
Ekanayake, JB ;
Holdsworth, L ;
Wu, XG ;
Jenkins, N .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (02) :803-809