Biceps brachii myoelectric and oxygenation changes during static and sinusoidal isometric exercises

被引:79
作者
Felici, Francesco [1 ,2 ]
Quaresima, Valentina [3 ]
Fattorini, Luigi [4 ]
Sbriccoli, Paola [1 ,2 ]
Filligoi, Gian Carlo [5 ,6 ]
Ferrari, Marco [3 ]
机构
[1] Ist Univ Sci Motorie, Dept Human Movement & Sport Sci, I-00194 Rome, Italy
[2] IIM, Chieti, Italy
[3] Univ Aquila, Dept Sci & Biomed Technol, Fac Med, I-67100 Laquila, Italy
[4] Univ Roma La Sapienza, Dept Human Physiol & Pharmacol, Fac Med, Rome, Italy
[5] Univ Roma La Sapienza, Dept Informat & Commun Sci INFOCOM, Fac Engn, Rome, Italy
[6] Univ Roma La Sapienza, Biomed Syst Res Ctr CISB, Rome, Italy
关键词
Surface electromyography; Near-infrared spectroscopy; Isometric exercise; Oxidative metabolism; Muscle O-2 saturation; Myoelectric fatigue; NEAR-INFRARED SPECTROSCOPY; FIBER CONDUCTION-VELOCITY; MUSCLE OXYGENATION; CYCLING EXERCISE; BLOOD-FLOW; FORCE; ELECTROMYOGRAPHY; EMG; CONTRACTION; VOLUNTARY;
D O I
10.1016/j.jelekin.2007.07.010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Surface myoelectric signal changes occurring during sustained isometric contractions have been extensively studied with quantitative surface electromyography (sEMG) and are described by means of some sEMG global variables in time and frequency domain (such as the median power spectral frequency). Recently, the possibility of studying local muscle O-2 saturation during exercise using non-invasive methods has been enhanced thanks to the use of near-infrared spectroscopy (NIRS). The purpose of this work was to combine NIRS and sEMG techniques to analyze the relationship between modifications of sEMG parameters and the underlying metabolic status of the exercising biceps brachii muscle. This relationship was tested under different isometric contraction modalities, namely static (ST) at 20, 40, 60 and 80%MVC and sinusoidal (SIN) at 40 +/- 20 and 60 +/- 20% MVC. Results clearly indicated the presence of an initial fast phase of muscle O-2 desaturation followed by a slow phase, regardless of the contraction modality. Moreover, the initial rate of muscle O-2 desaturation was related to the level of force output (R = 0.92), but it was independent on the contraction modality (p < 0.05). Similarly, changes in sEMG parameters were related to force level (Conduction Velocity-CV vs. Force: R = 0.87; sEMG Median Frequency-MDF vs. Force: R = 0.86). The high correlation found between CV-MDF and Tissue Oxygenation Index (TOI) slope (R = 0.73 and 0.72, respectively) suggests a strong relationship between NIRS and sEMG data. This study indicates that muscle O-2 demand during isometric contractions from low to high force levels is influenced by the type of active motor units and not from the type of isometric exercise modality. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:E1 / E11
页数:11
相关论文
共 37 条
[1]  
Basmajan JV, 1985, MUSCLES ALIVE THEIR
[2]   Muscle oxygenation trends during dynamic exercise measured by near infrared spectroscopy [J].
Bhambhani, YN .
CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 2004, 29 (04) :504-523
[3]   Human skeletal muscle fibres: molecular and functional diversity [J].
Bottinelli, R ;
Reggiani, C .
PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2000, 73 (2-4) :195-262
[4]   Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease [J].
Boushel, R ;
Langberg, H ;
Olesen, J ;
Gonzales-Alonzo, J ;
Bülow, J ;
Kjær, M .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2001, 11 (04) :213-222
[5]   Effects of prior heavy exercise on V(over dot)O2 kinetics during heavy exercise are related to changes in muscle activity [J].
Burnley, M ;
Doust, JH ;
Ball, D ;
Jones, AM .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (01) :167-174
[6]   ACTIVITY OF SINGLE MOTOR UNITS DURING ISOMETRIC TENSION [J].
CLAMANN, HP .
NEUROLOGY, 1970, 20 (03) :254-&
[7]   The use of surface electromyography in biomechanics [J].
De Luca, CJ .
JOURNAL OF APPLIED BIOMECHANICS, 1997, 13 (02) :135-163
[8]   Quantification in tissue near-infrared spectroscopy [J].
Delpy, DT ;
Cope, M .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 1997, 352 (1354) :649-659
[9]   Noninvasive estimation of motor unit conduction velocity distribution using linear electrode arrays [J].
Farina, D ;
Fortunato, E ;
Merletti, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (03) :380-388
[10]   Nonlinear surface EMG analysis to detect changes of motor unit conduction velocity and synchronization [J].
Farina, D ;
Fattorini, L ;
Felici, F ;
Filligoi, G .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (05) :1753-1763