Background and operating parameters in microemulsion electrokinetic chromatography

被引:101
作者
Altria, KD
Mahuzier, PE
Clark, BJ
机构
[1] GlaxoSmithKline Res & Dev Ltd, Ware, Herts, England
[2] Univ Bradford, Sch Pharm, Bradford BD7 1DP, W Yorkshire, England
关键词
capillary electrophoresis microemulsion electrokinetic chromatography; review;
D O I
10.1002/elps.200390041
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microemulsion electrokinetic chromatography (MEEKC) is an electrodriven separation technique. Separations are generally achieved using microemulsions consisting of surfactant-coated nanometer-sized oil droplets suspended in aqueous buffer. A cosurfactant such as a short-chain alcohol is generally used to stabilize the microemulsion. This review summarizes the various microemulsion types and compositions that have been used in MEEKC. The effects of key-operating variables such as surfactant type and concentration, cosurfactant type and concentration, buffer pH and type, oil type and concentration, use of organic solvent and cyclodextrin additions, and temperature are described. Specific examples of water-in-oil microemulsions and chirally selective separations are also covered.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 58 条
[1]   Linear free energy relationship analysis of microemulsion electrokinetic chromatographic determination of lipophilicity [J].
Abraham, MH ;
Treiner, C ;
Roses, M ;
Rafols, C ;
Ishihama, Y .
JOURNAL OF CHROMATOGRAPHY A, 1996, 752 (1-2) :243-249
[2]   USE OF A MICROEMULSION SYSTEM TO INCORPORATE A LIPOPHILIC CHIRAL SELECTOR IN ELECTROKINETIC CAPILLARY CHROMATOGRAPHY [J].
AIKEN, JH ;
HUIE, CW .
CHROMATOGRAPHIA, 1993, 35 (7-8) :448-450
[3]   Highly efficient and selective separations of a wide range of analytes obtained by an optimised microemulsion electrokinetic chromatography method [J].
Altria, KD .
CHROMATOGRAPHIA, 1999, 49 (7-8) :457-464
[4]   Application of microemulsion electrokinetic chromatography to the analysis of a wide range of pharmaceuticals and excipients [J].
Altria, KD .
JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) :371-386
[5]   The effect of operating variables in microemulsion electrokinetic capillary chromatography [J].
Altria, KD ;
Clark, BJ ;
Mahuzier, PE .
CHROMATOGRAPHIA, 2000, 52 (11-12) :758-768
[6]   Capillary electrophoretic separation of vitamins in sodium dodecyl sulfate containing buffers with lower aliphatic alcohols and n-hexane as organic modifiers [J].
Bellini, MS ;
Manetto, G ;
Deyl, Z ;
Tagliaro, F ;
Miksík, I .
JOURNAL OF CHROMATOGRAPHY B, 2000, 741 (01) :67-75
[7]   MICROEMULSION ELECTROKINETIC CHROMATOGRAPHY WITH DIFFERENT ORGANIC MODIFIERS - SEPARATION OF WATER-SOLUBLE AND LIPID-SOLUBLE VITAMINS [J].
BOSO, RL ;
BELLINI, MS ;
MIKSIK, I ;
DEYL, Z .
JOURNAL OF CHROMATOGRAPHY A, 1995, 709 (01) :11-19
[8]  
Cahours X, 2002, ELECTROPHORESIS, V23, P2320, DOI 10.1002/1522-2683(200207)23:14<2320::AID-ELPS2320>3.0.CO
[9]  
2-P
[10]   Separation of cardiac glycosides by micellar electrokinetic chromatography and microemulsion electrokinetic chromatography [J].
Debusschere, L ;
Demesmay, C ;
Rocca, JL ;
Lachatre, G ;
Lofti, H .
JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) :227-233