Discrepancies between catheter and Doppler estimates of valve effective orifice area can be predicted from the pressure recovery phenomenon

被引:163
作者
Garcia, D
Dumesnil, JG
Durand, LG
Kadem, L
Pibarot, P
机构
[1] Univ Laval, Laval Hosp, Quebec Heart Inst, St Foy, PQ G1V 4G5, Canada
[2] Inst Rech Clin Montreal, Lab Genie Biomed, Montreal, PQ H2W 1R7, Canada
基金
加拿大创新基金会; 加拿大健康研究院;
关键词
D O I
10.1016/S0735-1097(02)02764-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to obtain more coherent evaluations of aortic stenosis severity. BACKGROUND The valve effective orifice area (EOA) is routinely used to assess aortic stenosis severity. However, there are often discrepancies between measurements of EOA by Doppler echocardiography (EOA(Dop)) and those by a catheter (EOA(cath)). We hypothesized that these discrepancies might be due to the influence of pressure recovery. METHODS The relationship between EOA(cath) and EOA(Dop) was studied as follows: 1) in an in vitro model measuring the effects of different flow rates and aortic diameters on two fixed stenoses and seven bioprostheses; 2) in an animal model of supravalvular aortic stenosis (14 pigs); and 3) based on catheterization data from 37 patients studied by Schobel et al. RESULTS Pooling of in vitro, animal, and patient data showed a good correlation (r = 0.97) between EOA(cath) (range 0.3 to 2.3 cm(2)) and EOA(Dop) (range 0.2 to 1.7 cm(2)), but EOA(cath) systematically overestimated EOA(Dop) (24 +/- 17% [mean +/-SD]). However, when the energy loss coefficient (ELCo) was calculate in EOA(Dop) and aortic cross-sectional area (A(A)) to account for pressure recovery, a similar correlation (r = 0.97) with EOA(cath) was observed, but the previously noted overestimation was no longer present. CONCLUSIONS Discrepancies between EOA(cath) and EOA(Dop) are largely due to the pressure recovery phenomenon and can be reconciled by calculating ELCo from the echocardiogram. Thus, ELCo and EOA(cath) are equivalent indexes representing the net energy loss due to stenosis and probably are the most appropriate for quantifying aortic stenosis severity.
引用
收藏
页码:435 / 442
页数:8
相关论文
共 32 条
[1]   Overestimation of catheter gradients by Doppler ultrasound in patients with aortic stenosis: A predictable manifestation of pressure recovery [J].
Baumgartner, H ;
Stefenelli, T ;
Niederberger, J ;
Schima, H ;
Maurer, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) :1655-1661
[2]   ACC/AHA guidelines for the management of patients with valvular heart disease - A report of the American College of Cardiology American Heart Association Task Force on practice guidelines (Committee on Management of Patients with Valvular Heart Disease) [J].
Bonow, RO ;
Carabello, B ;
De Leon, AC ;
Edmunds, LH ;
Fedderly, BJ ;
Freed, MD ;
Gaasch, WH ;
Mckay, CR ;
Nishimura, RA ;
O'Gara, PT ;
O'Rourke, RA ;
Rahimtoola, SH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) :1486-1582
[3]   DEPENDENCE OF GORLIN FORMULA AND CONTINUITY EQUATION VALVE AREAS ON TRANSVALVULAR VOLUME FLOW-RATE IN VALVULAR AORTIC-STENOSIS [J].
BURWASH, IG ;
THOMAS, DD ;
SADAHIRO, M ;
PEARLMAN, AS ;
VERRIER, ED ;
THOMAS, R ;
KRAFT, CD ;
OTTO, CM .
CIRCULATION, 1994, 89 (02) :827-835
[4]   HYDRAULIC ESTIMATION OF STENOTIC ORIFICE AREA - A CORRECTION OF THE GORLIN FORMULA [J].
CANNON, SR ;
RICHARDS, KL ;
CRAWFORD, M .
CIRCULATION, 1985, 71 (06) :1170-1178
[5]  
CHAMBERS JB, 1992, BRIT HEART J, V67, P193
[6]   FLUID-MECHANICS OF AORTIC-STENOSIS .1. THEORY AND STEADY FLOW EXPERIMENTS [J].
CLARK, C .
JOURNAL OF BIOMECHANICS, 1976, 9 (08) :521-528
[7]   FLUID-MECHANICS OF AORTIC-STENOSIS .2. UNSTEADY-FLOW EXPERIMENTS [J].
CLARK, C .
JOURNAL OF BIOMECHANICS, 1976, 9 (09) :567-&
[8]   ECHOCARDIOGRAPHIC ASSESSMENT OF AORTIC-VALVE AREA IN ELDERLY PATIENTS WITH AORTIC-STENOSIS AND OF CHANGES IN VALVE AREA AFTER PERCUTANEOUS BALLOON VALVULOPLASTY [J].
COME, PC ;
RILEY, MF ;
MCKAY, RG ;
SAFIAN, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (01) :115-124
[9]   FACTORS AFFECTING DOPPLER ECHOCARDIOGRAPHIC VALVE AREA ASSESSMENT IN AORTIC-STENOSIS [J].
DANIELSEN, R ;
NORDREHAUG, JE ;
VIKMO, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (15) :1107-1111
[10]   THEORETICAL AND PRACTICAL DIFFERENCES BETWEEN THE GORLIN FORMULA AND THE CONTINUITY EQUATION FOR CALCULATING AORTIC AND MITRAL-VALVE AREAS [J].
DUMESNIL, JG ;