摘要
This paper presents an enhanced current controller for improving the performance of a class of single-phase gridconnected inverters operating in weak and distorted grid conditions. An inverter designed to operate at normal (strong or stiff and clean) grid conditions may not perform satisfactorily during weak and distorted grid conditions. One major reason is the interfering dynamics of the synchronization or phase-locked loop (PLL). This paper proposes an enhanced control structure for a popular class of single-phase inverters to address this problem. The proposed idea is to include the PLL state variables into the main inverter controller thereby minimizing the undesirable interactions of the PLL with the other components. A method for optimally designing the controller gains is also proposed. Compared to the conventional one, the proposed controller is shown to have a more robust performance over a substantially wider range of weak and distorted grid conditions. Extensive simulation and experimental results are presented to validate the proposed controls.
引用
收藏
页码:12538 / 12551
页数:14
相关论文
共 35 条
  • [1] Ackermann T, 2005, WIND POWER IN POWER SYSTEMS, P1, DOI 10.1002/0470012684
  • [2] A comprehensive control system for multi-parallel grid-connected inverters with LCL filter in weak grid condition
    Akhavan, Ali
    Mohammadi, Hamid Reza
    Guerrero, Josep M.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2018, 163 : 288 - 300
  • [3] Three-phase phase-locked loop synchronization algorithms for grid-connected renewable energy systems: A review
    Ali, Zunaib
    Christofides, Nicholas
    Hadjidemetriou, Lenos
    Kyriakides, Elias
    Yang, Yongheng
    Blaabjerg, Frede
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 90 : 434 - 452
  • [4] [Anonymous], 2010, UL1741
  • [5] [Anonymous], 2015, PROC 11 IET INT C AC
  • [6] [Anonymous], 2012, 2012 IEEE POW EN SOC
  • [7] Baldick R, 2009, 2009 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION, VOLS 1-3, P83
  • [8] California Public Utility Commission, 2017, RUL 21 INT
  • [9] Control Design Guidelines for Single-Phase Grid-Connected Photovoltaic Inverters With Damped Resonant Harmonic Compensators
    Castilla, Miguel
    Miret, Jaume
    Matas, Jose
    Garcia de Vicuna, Luis
    Guerrero, Josep M.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (11) : 4492 - 4501
  • [10] Robust Vector Control of a Very Weak-Grid-Connected Voltage-Source Converter Considering the Phase-Locked Loop Dynamics
    Davari, Masoud
    Mohamed, Yasser Abdel-Rady I.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (02) : 977 - 994