Moxifloxacin hydrochloride electrochemical detection based on newly designed molecularly imprinted polymer

被引:45
作者
Hammam, Mennatallah A. [1 ]
Wagdy, Hebatallah A. [2 ,3 ]
El Nashar, Rasha M. [4 ]
机构
[1] German Univ Cairo, Fac Pharm & Biotechnol, Pharmaceut Chem Dept, New Cairo City, Egypt
[2] British Univ Egypt, Fac Pharm, Pharmaceut Chem Dept, POB 43, Cairo 11837, Egypt
[3] British Univ Egypt, Fac Pharm, CDRD, POB 43, Cairo 11837, Egypt
[4] Cairo Univ, Fac Sci, Chem Dept, Giza, Egypt
关键词
Avalox; Moxifloxacin hydrochloride; Molecularly imprinted polymer; Potentiometric sensor; Standard addition method; ION-SELECTIVE ELECTRODES; SENSOR; PERFORMANCE; FLUOROQUINOLONES; RECOGNITION; EXTRACTION; BINDING; AGENT; BULK;
D O I
10.1016/j.snb.2018.08.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Moxifloxacin HCl, a fourth generation fluoroquinolone antibacterial agent developed to treat some respiratory and dermatological infections. In this paper, a molecularly imprinted polymer was developed for specific recognition and quantification of moxifloxacin HCl in different matrices. Nine molecularly imprinted polymers were synthesized using moxifloxacin HCl as the template, methacrylic acid or 4- vinylpyridine as the functional monomers, ethylene glycol dimethacrylate as the cross linker and mixture of dimethyl sulfoxide and acetonitrile as the porogen. Following the non-covalent approach, polymers were prepared using thermal free radical bulk polymerization method. Best binding performance was for the polymer prepared using the ratio of 1:4:20 (template: functional monomer: crosslinker) in both water and methanol. This molecularly imprinted polymer was used as the recognition material in potentiometric based PVC membranes. Effect of the amount of polymer, type of plasticizer, soaking time and pH of the sample solution were studied. The sensor containing 1% MIP, 33% PVC and 66% DOP showed the nearest slope (55.9 +/- 0.86 mV/decade) to the Nernestian values over concentration range (1.0 x 10(-5)to 1.0 x 10(-2)M). It was used for the determination of moxifloxacin HCl in its pure form, Avalox tablets (400 mg/tablet) and spiked human urine samples using the standard addition method with mean percentage recoveries ranging from 96.6 to 102.8%. Lifetime of the sensor was found to be 4 months when kept dry in air.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 50 条
[1]  
Allender CJ, 1997, CHIRALITY, V9, P233, DOI 10.1002/(SICI)1520-636X(1997)9:3<233::AID-CHIR5>3.0.CO
[2]  
2-G
[3]  
Annamma K.M., 2011, Mater. Sci. Appl, V2, P131, DOI DOI 10.4236/MSA.2011.23017
[4]  
APIBHP Inc. N.J. Wayne U.S.A., 2012, NON TRADITIONAL REF
[5]   Development and validation of sensitive kinetic spectrophotometric method for the determination of moxifloxacin antibiotic in pure and commercial tablets [J].
Ashour, Safwan ;
Bayram, Roula .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2015, 140 :216-222
[6]   TRACE FLUORIDE DETERMINATION WITH SPECIFIC ION ELECTRODE [J].
BAUMANN, EW .
ANALYTICA CHIMICA ACTA, 1968, 42 (01) :127-&
[7]   Correlation between adsorption and small molecule hydrogen bonding [J].
Brune, BJ ;
Koehler, JA ;
Smith, PJ ;
Payne, GF .
LANGMUIR, 1999, 15 (11) :3987-3992
[8]   Simultaneous analysis of antibiotics in biological samples by ultra high performance liquid chromatography-tandem mass spectrometry [J].
Cazorla-Reyes, Rocio ;
Romero-Gonzalez, Roberto ;
Garrido Frenich, Antonia ;
Rodriguez Maresca, Manuel Angel ;
Martinez Vidal, Jose Luis .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 89 :203-212
[9]   Molecular imprinting: perspectives and applications [J].
Chen, Lingxin ;
Wang, Xiaoyan ;
Lu, Wenhui ;
Wu, Xiaqing ;
Li, Jinhua .
CHEMICAL SOCIETY REVIEWS, 2016, 45 (08) :2137-2211
[10]   Enantiomeric purity assay of moxifloxacin hydrochloride by capillary electrophoresis [J].
Cruz, LA ;
Hall, R .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 38 (01) :8-13