摘要
Purpose: The aim of this study is to assess the agreement between manual and automated gonioscopy for iridocorneal angle opening. Methods: The research is a cross-sectional observational study. Manual and automated gonioscopy were performed to consecutive patients in a glaucoma clinic. Iridocorneal angle opening grading was performed according to Shaffer's classification. Automated gonioscopy was performed with NGS-1 automated gonioscope (NIDEK Co., Gamagori, Japan). The automated gonio-photos were graded by two independent observers. Agreement between automated and manual gonioscopy and also among raters was ascertained by Fleiss' kappa statistic and comparison of area under curve. Results: In total, 88 eyes of 47 subjects were analysed. Mean age was 63 +/- 10 years. Twenty eyes (22.7%) were excluded from grading due to poor quality images. Angle closure was detected in 23.4% with dynamic gonioscopy in comparison with 4.3% using automated image grading. The agreement for angle closure diagnosis between dynamic and automated gonioscopy was low (kappa = 0.09 +/- 0.10; p = 0.18). The area under curve for detecting eyes with angle closure showed poor accuracy between automated and manual methods (area under curve: 0.53 +/- 0.05, 95% confidence interval: 0.44-0.62). There was modest inter-rater agreement for angle opening assessment of automated images with Fleiss' kappa of 0.17 (95% confidence interval: 0.035-0.238). Conclusion: Manual and automated gonioscopy showed only slight agreement for the assessment of iridocorneal angle opening status. Further improvements of the NGS-1 automated gonioscopy and technique are desired for widespread use in a real-life setting.
引用
收藏
页码:112 / 118
页数:7
相关论文
共 22 条
  • [1] Automated segmentation of the optic disc from stereo color photographs using physiologically plausible features
    Abramoff, Michael D.
    Alward, Wallace L. M.
    Greenlee, Emily C.
    Shuba, Lesya
    Kim, Chan Y.
    Fingert, John H.
    Kwon, Young H.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (04) : 1665 - 1673
  • [2] Alward WLM, 1994, COLOR ATLAS GONIOSCO
  • [3] Automated Analysis of Angle Closure From Anterior Chamber Angle Images
    Baskaran, Mani
    Cheng, Jun
    Perera, Shamira A.
    Tun, Tin A.
    Liu, Jiang
    Aung, Tin
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (11) : 7669 - 7673
  • [4] Angle Assessment by EyeCam, Goniophotography, and Gonioscopy
    Baskaran, Mani
    Perera, Shamira A.
    Nongpiur, Monisha E.
    Tun, Tin A.
    Park, Judy
    Kumar, Rajesh S.
    Friedman, David S.
    Aung, Tin
    [J]. JOURNAL OF GLAUCOMA, 2012, 21 (07) : 493 - 497
  • [5] Agreement and Accuracy of Non-Expert Ophthalmologists in Assessing Glaucomatous Changes in Serial Stereo Optic Disc Photographs
    Breusegem, Christophe
    Fieuws, Steffen
    Stalmans, Ingeborg
    Zeyen, Thierry
    [J]. OPHTHALMOLOGY, 2011, 118 (04) : 742 - 746
  • [6] Cantor LB, 2015, 2015 2016 BASIC CLIN
  • [7] Use of gonioscopy in Medicare beneficiaries before glaucoma surgery
    Coleman, Anne L.
    Yu, Fei
    Evans, Stacy J.
    [J]. JOURNAL OF GLAUCOMA, 2006, 15 (06) : 486 - 493
  • [8] European Glaucoma Society, 2017, BR J OPHTHALMOL, V101, P39
  • [9] THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1982, 143 (01) : 29 - 36
  • [10] Glaucoma care and conformance with preferred practice patterns - Examination of the private, community-based ophthalmologist
    Hertzog, LH
    Albrecht, KG
    LaBree, L
    Lee, PP
    [J]. OPHTHALMOLOGY, 1996, 103 (07) : 1009 - 1013