Hot Plasma Composition Analyzer for the Magnetospheric Multiscale Mission

被引:176
作者
Young, D. T. [1 ]
Burch, J. L. [1 ]
Gomez, R. G. [1 ]
De Los Santos, A. [1 ]
Miller, G. P. [1 ]
Wilson, P. [1 ]
Paschalidis, N. [4 ]
Fuselier, S. A. [1 ]
Pickens, K. [1 ]
Hertzberg, E. [2 ]
Pollock, C. J. [5 ]
Scherrer, J. [1 ]
Wood, P. B. [1 ]
Donald, E. T. [3 ]
Aaron, D. [1 ]
Furman, J. [1 ]
George, D. [1 ]
Gurnee, R. S. [3 ]
Hourani, R. S. [3 ]
Jacques, A. [4 ]
Johnson, T. [1 ]
Orr, T. [1 ]
Pan, K. S. [1 ]
Persyn, S. [1 ]
Pope, S. [1 ]
Roberts, J. [1 ]
Stokes, M. R. [3 ]
Trattner, K. J. [6 ]
Webster, J. M. [1 ]
机构
[1] SW Res Inst, Space Sci & Engn Div, San Antonio, TX 78238 USA
[2] Lockheed Martin Adv Technol Ctr, Palo Alto, CA 94304 USA
[3] Johns Hopkins Univ, Appl Phys Lab, Space Explorat Sect, Johns Hopkins Rd, Laurel, MD 20723 USA
[4] NASA, Goddard Space Flight Ctr, Code 670, Greenbelt, MD 20771 USA
[5] NASA, Goddard Space Flight Ctr, Code 673, Greenbelt, MD 20771 USA
[6] Univ Colorado, Atmospher & Space Phys Lab, Boulder, CO 80303 USA
基金
美国国家科学基金会;
关键词
Plasma ion composition; Reconnection measurements; Time-of-Flight mass spectrometry; ION COMPOSITION; MASS-SPECTROMETER; SPACE PLASMAS; RECONNECTION; DYNAMICS;
D O I
10.1007/s11214-014-0119-6
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
This paper describes the science motivation, measurement objectives, performance requirements, detailed design, approach and implementation, and calibration of the four Hot Plasma Composition Analyzers (HPCA) for the Magnetospheric Multiscale mission. The HPCA is based entirely on electrostatic optics combining an electrostatic energy analyzer with a carbon-foil based time-of-flight analyzer. In order to fulfill mission requirements, the HPCA incorporates three unique technologies that give it very wide dynamic range capabilities essential to measuring minor ion species in the presence of extremely high proton fluxes found in the region of magnetopause reconnection. Dynamic range is controlled primarily by a novel radio frequency system analogous to an RF mass spectrometer. The RF, in combination with capabilities for high TOF event processing rates and high current micro-channel plates, ensures the dynamic range and sensitivity needed for accurate measurements of ion fluxes between similar to 1 eV and 40 keV that are expected in the region of reconnection events. A third technology enhances mass resolution in the presence of high proton flux. In order to calibrate the four HPCA instruments we have developed a unique ion calibration system. The system delivers a multi-species beam resolved to M/Delta M similar to 100 and current densities between 0.05 and 200 pA/cm(2) with a stability of +/- 5 %. The entire system is controlled by a dedicated computer synchronized with the HPCA ground support equipment. This approach results not only in accurate calibration but also in a comprehensive set of coordinated instrument and auxiliary data that makes analysis straightforward and ensures archival of all relevant data.
引用
收藏
页码:407 / 470
页数:64
相关论文
共 28 条
  • [1] Energy loss of 1-50 keV H, He, C, N, O, Ne, and Ar ions transmitted through thin carbon foils
    Allegrini, F
    McComas, DJ
    Young, DT
    Berthelier, JJ
    Covinhes, J
    Illiano, JM
    Riou, JF
    Funsten, HO
    Harper, RW
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (04)
  • [2] Balsiger H., 1976, Space Science Instrumentation, V2, P499
  • [3] Technique for increasing dynamic range of space-borne ion composition instruments
    Burch, JL
    Miller, GP
    De Los Santos, A
    Pollock, CJ
    Pope, SE
    Valek, PW
    Young, DT
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (10) : 1 - 4
  • [4] Position Sensing Using Pico-Second Timing With Micro-Channel Plate Devices and Waveform Sampling
    Byrum, Karen
    Frisch, Henry J.
    Genat, Jean-Francois C.
    Heintz, Mary K.
    May, Edward N.
    Natoli, Tyler
    Tang, Fukun
    Yurtsev, Eugene
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (02) : 525 - 532
  • [5] The geometric factor of electrostatic plasma analyzers: A case study from the Fast Plasma Investigation for the Magnetospheric Multiscale mission
    Collinson, Glyn A.
    Dorelli, John C.
    Avanov, Levon A.
    Lewis, Gethyn R.
    Moore, Thomas E.
    Pollock, Craig
    Kataria, Dhiren O.
    Bedington, Robert
    Arridge, Chris S.
    Chornay, Dennis J.
    Gliese, Ulrik
    Mariano, Al
    Barrie, Alexander C.
    Tucker, Corey
    Owen, Christopher J.
    Walsh, Andrew P.
    Shappirio, Mark D.
    Adrian, Mark L.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (03)
  • [6] Ion heating resulting from pickup in magnetic reconnection exhausts
    Drake, J. F.
    Swisdak, M.
    Phan, T. D.
    Cassak, P. A.
    Shay, M. A.
    Lepri, S. T.
    Lin, R. P.
    Quataert, E.
    Zurbuchen, T. H.
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2009, 114
  • [7] Plasma moments in the environment of mars
    Franz, M.
    Dubinin, E.
    Roussos, E.
    Woch, J.
    Winningham, J. D.
    Frahm, R.
    Coates, A. J.
    Fedorov, A.
    Barabash, S.
    Lundin, R.
    [J]. SPACE SCIENCE REVIEWS, 2006, 126 (1-4) : 165 - 207
  • [8] GEISS J, 1978, SPACE SCI REV, V22, P537, DOI 10.1007/BF00223940
  • [9] ION COMPOSITION MEASUREMENT TECHNIQUES FOR SPACE PLASMAS
    GLOECKLER, G
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (11) : 3613 - 3620
  • [10] Gomez R.G., 2011, THESIS RICE U