Investigation of the launch time of NH3-H2O absorption chiller under different working condition

被引:2
作者
Ebrahimnataj Tiji, A. [1 ]
Ramiar, A. [2 ]
Ebrahimnataj, M. R. [3 ]
机构
[1] Semnan Univ, Dept Mech Engn, Semnan, Iran
[2] Babol Noshirvani Univ Technol, Fac Mech Engn, Babol Sar, Iran
[3] Qom Univ Technol, Dept Mech Engn, Qom, Iran
关键词
Transient; subcool; aqua-ammonia; absorption chiller; launch time; DYNAMIC SIMULATION-MODEL; HEAT-PUMP; PERFORMANCE; SYSTEM; BEHAVIOR;
D O I
10.1177/0954408919879871
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study deals with the launch time of main characteristic of NH3-H O-2 absorption chiller under different working condition. The aim of this work was about to scrutinize a lumped-parameter dynamic simulation of aqua-ammonia absorption chiller in addition to investigating the effect of subcooled liquid at condenser/absorber outlet on absorption chiller's key parameters launch time. Also, the effect of ambient temperature on absorption chiller's key parameters' launch time is studied. In order to determine the thermodynamic properties of the working fluid, the Engineering Equation Solver software is applied. By making a link between Engineering Equation Solver and MATLAB software, the differential equations are solved in the MATLAB software environment by fourth-order Rung-Kutta method. According to the result, increase of the sub-cool liquid temperature at condenser outlet has no effect on absorption chiller's key parameters' launch time. Besides, 10 celcius-increase in subcooled liquid temperature at the absorber outlet leads to decreasing the launch time of the coefficient of performance to 19.35%. The result shows that if cooling tower temperature goes from 22 celcius to 30 celcius, launch time of the coefficient of performance rises by 10.43%, while evaporator heat transfer rate falls by 30%. To validate the dynamic model, the results deduced from numerical simulation are compared with peer steady-state results.
引用
收藏
页码:15 / 28
页数:14
相关论文
共 27 条
[1]   The effect of input temperatures on the absorber parameters [J].
Atmaca, I ;
Yigit, A ;
Kilic, M .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2002, 29 (08) :1177-1186
[2]   DYNAMIC BEHAVIOR OF AN ABSORPTION HEAT-PUMP [J].
BUTZ, D ;
STEPHAN, K .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1989, 12 (04) :204-212
[3]  
Cai W, 2010, IND ENG CHEM RES, V51, P2070, DOI DOI 10.1021/IE200673F
[4]   Dynamic Simulation of an Absorption Cooling System with Different Working Mixtures [J].
Cerezo, Jesus ;
Romero, Rosenberg J. ;
Ibarra, Jonathan ;
Rodriguez, Antonio ;
Montero, Gisela ;
Acuna, Alexis .
ENERGIES, 2018, 11 (02)
[5]   Dynamic modeling and simulation of a double-effect absorption heat pump [J].
de la Calle, Alberto ;
Roca, Lidia ;
Bonilla, Javier ;
Palenzuela, Patricia .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 72 :171-191
[6]  
Dence AE, 1996, PROC IECEC, P1041, DOI 10.1109/IECEC.1996.553843
[7]   Implementation of an object-oriented dynamic modeling library for absorption refrigeration systems [J].
Fu, DG ;
Poncia, G ;
Lu, Z .
APPLIED THERMAL ENGINEERING, 2006, 26 (2-3) :217-225
[8]  
Herold K.E., 1996, Absorption Chillers and Heat Pumps
[9]   Dynamic simulation of a single-effect LiBr-H2O absorption refrigeration cycle considering the effects of thermal masses [J].
Iranmanesh, A. ;
Mehrabian, M. A. .
ENERGY AND BUILDINGS, 2013, 60 :47-59
[10]   Dynamic simulation of an absorption heat pump for recovering low grade waste heat [J].
Jeong, S ;
Kang, BH ;
Karng, SW .
APPLIED THERMAL ENGINEERING, 1998, 18 (1-2) :1-12