Identification of the Main Sources of Noise in the NICU of Hospital in Iran and Offering Noise Control Methods

被引:0
作者
Shariatzadeh, Hanieh [1 ]
Abazari, Malek [2 ]
Feiz-Arefi, Maryam [3 ]
Amani, Olamz [4 ]
Moazez-Ardebil, Nastaran [4 ]
Babaei-Pouya, Amin [5 ]
机构
[1] Ardabil Univ, Sch Publ Hlth, Res, Ardebil, Iran
[2] Ardabil Univ Med Sci, Social Determinants Hlth Res Ctr, Ardebil, Iran
[3] Shoushtar Fac Med Sci, Shoushtar, Iran
[4] Ardabil Univ Med Sci, Ardebil, Iran
[5] Ardabil Univ Med Sci, Sch Hlth, Dept Occupat Hlth Engn, Ardebil, Iran
来源
PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES | 2021年 / 15卷 / 04期
关键词
Neonatal Intensive Care Unit; Hospital; Sound Level; Noise Control;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: High ambient sounds affect the hearing system of premature infants and cause direct adverse effects in the development of the central nervous system. Aim: The aim of this research is to identify the main sources of noise generator, which results in the generation of sounds that are more than the prescribed limit. Method: This study is descriptive-analytic. The NICU's research site in the hospital. Measurement and evaluation of sound were performed by an expert on professional health using a calibrated Sound Meter set of KIMO SDA type. The sound map of various situations was mapped using the Surfer software and compared with the standard exposure limit. Result: The mean SPL in NICU was 61 dB. The analysis of the data showed that during 24 hours, the morning shift has the highest and the night shift has the lowest noise. The main noise generator factors in the NICU section are ventilated pulse oximeter set and active personnel. Conclusions: The proposed noise control methods include: Creating a Single-Patient Room, covering NICU's wall, floor, and ceiling, or baby's holding area with sound-absorbing panels to reduce the background noise of the unit, eliminating unnecessary alarms.
引用
收藏
页码:1117 / 1119
页数:3
相关论文
共 19 条
[1]  
Abazari M, 2020, MALAYSIAN J MED HLTH, V16, P137
[2]  
Abbasi S, 2012, J ISFAHAN MED SCH, V28, P1267
[3]  
Abril A, 2007, J PHYS C SERIES, V90, P1, DOI [10.1088/1742-6596/90/1/012038, DOI 10.1088/1742-6596/90/1/012038]
[4]   Noise levels in neonatal intensive care unit and use of sound absorbing panel in the isolette [J].
Altuncu, E. ;
Akman, I. ;
Kulekci, S. ;
Akdas, F. ;
Bilgen, H. ;
Ozek, E. .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2009, 73 (07) :951-953
[5]  
Babaei Pouya A, 2019, SHIRAZ EMEDICAL J, V20
[6]   Noise and the premature infant: Physiological effects and practice implications [J].
Bremmer, P ;
Byers, JF ;
Kiehl, E .
JOGNN-JOURNAL OF OBSTETRIC GYNECOLOGIC AND NEONATAL NURSING, 2003, 32 (04) :447-454
[7]  
Evans JB, 2000, J PERINATOL, V20, P105
[8]  
Hokmabadi R, 2013, JNKUMS, V5, P331
[9]  
Karimi R, 2014, J KNOWLEDGE HLTH, V9, P45
[10]   The effectiveness of environmental strategies on noise reduction in a pediatric intensive care unit: Creation of single-patient bedrooms and reducing noise sources [J].
Kol, Emine ;
Aydin, Perihan ;
Dursun, Oguz .
JOURNAL FOR SPECIALISTS IN PEDIATRIC NURSING, 2015, 20 (03) :210-217