摘要
One of the main issues in hearing-aid fittings is the abnormal perception of the user's own voice as too loud, "boomy," or "hollow." This phenomenon known as the occlusion effect be reduced by large vents in the earmolds or by open-fit hearing aids. This review provides an overview of publications related to open and closed hearing-aid fittings. First, the occlusion effect and its consequences for perception while using hearing aids are described. Then, the advantages and disadvantages of open compared with closed fittings and their impact on the fitting process are addressed. The advantages include less occlusion, improved own-voice perception and sound quality, and increased localization performance. The disadvantages associated with open-fit hearing aids include reduced benefits of directional microphones and noise reduction, as well as less compression and less available gain before feedback. The final part of this review addresses the need for new approaches to combine the advantages of open and closed hearing-aid fittings.
引用
收藏
页数:13
相关论文
共 100 条
[1]   The Accuracy of Matching Target Insertion Gains With Open-Fit Hearing Aids [J].
Aazh, Hashir ;
Moore, Brian C. J. ;
Prasher, Deepak .
AMERICAN JOURNAL OF AUDIOLOGY, 2012, 21 (02) :175-180
[2]   Real ear measurement methods for open fit hearing aids: Modified pressure concurrent equalization (MPCE) versus modified pressure stored equalization (MPSE) [J].
Aazh, Hashir ;
Moore, Brian C. J. ;
Prasher, Deepak .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2012, 51 (02) :103-107
[3]  
[Anonymous], 2012, HEARING AIDS
[4]  
[Anonymous], 1997, S346 ANSI
[5]  
[Anonymous], 2001, 12124 ISO
[6]  
[Anonymous], 1999, J AM ACAD AUDIOL
[7]  
Bayer E., 2008, U.S. Patent, Patent No. [7,340,075 B2, 7340075]
[8]  
Bernier A., 2013, P M AC AC SOC AM, V19
[9]  
Bernier A., 2015, EURONOISE 2015
[10]  
Blau M., 2008, ACOUSTICS 08