A feasibility study of full-field X-ray orientation microscopy at the onset of deformation twinning

被引:11
|
作者
Vigano, Nicola [1 ,2 ,3 ]
Nervo, Laura [2 ,6 ]
Valzania, Lorenzo [2 ]
Singh, Gaurav [6 ]
Preuss, Michael [6 ]
Batenburg, Kees Joost [3 ,4 ,5 ]
Ludwig, Wolfgang [1 ,2 ]
机构
[1] Univ Lyon, INSA Lyon, CNRS, MATEIS UMR5510, Lyon, France
[2] ESRF Grenoble, Grenoble, France
[3] Univ Antwerp, iMinds Vis Lab, Antwerp, Belgium
[4] CWI, Amsterdam, Netherlands
[5] Leiden Univ, NL-2300 RA Leiden, Netherlands
[6] Univ Manchester, Sch Mat, Manchester M13 9PL, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
X-ray orientation microscopy; full-field imaging; grain microstructure; deformation twinning; RECONSTRUCTION; TOMOGRAPHY; GRAINS;
D O I
10.1107/S1600576716002302
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Three-dimensional X-ray orientation microscopy based on X-ray full-field imaging techniques such as diffraction contrast tomography is a challenging task when it comes to materials displaying non-negligible intragranular orientation spread and/or intricate grain microstructures as a result of plastic deformation and deformation twinning. As shown in this article, the optimization of the experimental conditions and a number of modifications of the data analysis routines enable detection and three-dimensional reconstruction of twin lamellae down to micrometre thickness, as well as more accurate three-dimensional reconstruction of grains displaying intragranular orientation spreads of up to a few degrees. The reconstruction of spatially resolved orientation maps becomes possible through the use of a recently introduced six-dimensional reconstruction framework, which has been further extended in order to enable simultaneous reconstruction of parent and twin orientations and to account for the finite impulse response of the X-ray imaging detector. The simultaneous reconstruction of disjoint orientation domains requires appropriate scaling of the scattering intensities based on structure and Lorentz factors and yields three-dimensional reconstructions with comparable density values for all the grains. This in turn enables the use of a global intensity-guided assembly procedure and avoids problems related to the single-grain thresholding procedure used previously. Last but not least, carrying out a systematic search over the list of known twin variants (forward modelling) for each of the indexed parent grains, it is possible to identify additional twins which have been left undetected at the previous stage of grain indexing based on diffraction spot peak positions. The enhanced procedure has been tested on a 1% deformed specimen made from a Ti-4% Al alloy and the result has been cross-validated against a two-dimensional electron backscatter diffraction orientation map acquired on one of the lateral sample surfaces.
引用
收藏
页码:544 / 555
页数:12
相关论文
共 50 条
  • [1] Three-dimensional full-field X-ray orientation microscopy
    Nicola Viganò
    Alexandre Tanguy
    Simon Hallais
    Alexandre Dimanov
    Michel Bornert
    Kees Joost Batenburg
    Wolfgang Ludwig
    Scientific Reports, 6
  • [2] Three-dimensional full-field X-ray orientation microscopy
    Vigano, Nicola
    Tanguy, Alexandre
    Hallais, Simon
    Dimanov, Alexandre
    Bornert, Michel
    Batenburg, Kees Joost
    Ludwig, Wolfgang
    SCIENTIFIC REPORTS, 2016, 6
  • [3] Laboratory Full-Field Transmission X-ray Microscopy
    Seim, Christian
    Baumann, Jonas
    Legalla, Herbert
    Redlich, Christoph
    Mantouvalou, Ioanna
    Blobel, G.
    Stiel, Holger
    Kanngiesser, Birgit
    SHORT-WAVELENGTH IMAGING AND SPECTROSCOPY SOURCES, 2012, 8678
  • [4] Full-field transmission x-ray microscopy at SSRL
    Andrews, J. C.
    Brennan, S.
    Pianetta, P.
    Ishii, H.
    Gelb, J.
    Feser, M.
    Rudati, J.
    Tkachuk, A.
    Yun, W.
    9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
  • [5] Applications of Hard X-ray Full-Field Transmission X-ray Microscopy at SSRL
    Liu, Y.
    Andrews, J. C.
    Meirer, F.
    Mehta, A.
    Carrasco Gil, S.
    Sciau, P.
    Mester, Z.
    Pianetta, P.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 357 - 360
  • [6] Magnetic imaging with full-field soft X-ray microscopy
    Fischer, P.
    Eimüller, T.
    Goll, D.
    Stoll, H.
    Puzic, A.
    Schütz, G.
    Denbeaux, G.
    International Journal of Materials Research, 2002, 93 (05) : 377 - 382
  • [7] Magnetic imaging with full-field soft X-ray microscopy
    Fischer, P
    Eimüller, T
    Goll, D
    Stoll, H
    Puzic, A
    Schütz, G
    Denbeaux, G
    ZEITSCHRIFT FUR METALLKUNDE, 2002, 93 (05): : 377 - 382
  • [8] Full-field hard x-ray microscopy with interdigitated silicon lenses
    Simons, Hugh
    Stohr, Frederik
    Michael-Lindhard, Jonas
    Jensen, Flemming
    Hansen, Ole
    Detlefs, Carsten
    Poulsen, Henning Friis
    OPTICS COMMUNICATIONS, 2016, 359 : 460 - 464
  • [9] Multi-Lens Array Full-Field X-ray Microscopy
    Opolka, Alexander
    Mueller, Dominik
    Fella, Christian
    Balles, Andreas
    Mohr, Juergen
    Last, Arndt
    APPLIED SCIENCES-BASEL, 2021, 11 (16):
  • [10] Full-field transmission x-ray microscopy for bio-imaging
    Andrews, J. C.
    Brennan, S.
    Liu, Y.
    Pianetta, P.
    Almeida, E. A. C.
    van der Meulen, M. C. H.
    Wu, Z.
    Mester, Z.
    Ouerdane, L.
    Gelb, J.
    Feser, M.
    Rudati, J.
    Tkachuk, A.
    Yun, W.
    9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186