Non-invasive Glucose Monitoring System Utilizing Near-Infrared Technology

被引:1
|
作者
Duc Trinh-Minh Dinh [1 ]
Viet Anh Truong [1 ]
An Nhu-Phu Tran [1 ]
Hieu Xuan Le [1 ]
Hien Thi-Thu Pham [1 ]
机构
[1] Int Univ Vietnam Natl Univ HCMC, Biomed Engn Dept, Ho Chi Minh City 70000, Vietnam
来源
7TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM (BME7): TRANSLATIONAL HEALTH SCIENCE AND TECHNOLOGY FOR DEVELOPING COUNTRIES | 2020年 / 69卷
关键词
Near-infrared; Non-invasive; Blood glucose; Diabetes;
D O I
10.1007/978-981-13-5859-3_71
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Regular monitoring of glucose concentration is essential and urgency, especially diabetics. However, those methods which involve finger puncturing are invasive, expensive as well as painful. Also, there are risks of infectious diseases using these techniques due to the contact of the needle on human skin. This paper proposed a non-invasive glucose monitoring system utilizing the near-infrared (NIR) light to measure the glucose concentration in the human blood. The designed system uses a 980 nm-wavelength NIR LED transmitting through D-glucose phantom samples, a photo-sensor for analyzing the transmitting optical parameters, a filter & an amplifier circuit, and a Nano Arduino microcontroller. For calculating the values of glucose concentration, the R programming with the methodology of the artificial neural network (ANN) was applied. This type of methodology is considered as one of the most useful technique in the world of data analysis and because it is adaptive, learns from the provided information and optimizes for better prediction outcomes. The ANN is used to predict the correlation equation between collected voltage and glucose concentration. The obtained glucose level is demonstrated directly on the system's screen or further sent to the user's mobile phone. The result obtained shows a correlation between the transmittance and the concentration of D-glucose solution. The correlation parameter of the technique is R-2 = 0.9957. Despite having the acceptable results, there are still some improvements that could be carried out for more accurate measurement (angle of the LED, a procedure of filtering and amplifying, usage of an optical instrument.). For further investigation and development, it is predicted that the result can be more accurate, precise and sensitivity as much as possible.
引用
收藏
页码:401 / 405
页数:5
相关论文
共 50 条
  • [21] Non-invasive glucose monitoring technology in diabetes management: A review
    Vashist, Sandeep Kumar
    ANALYTICA CHIMICA ACTA, 2012, 750 : 16 - 27
  • [22] The feasibility investigation of non-invasive blood glucose sensing based on near-infrared spectroscopy
    Gu, Xiaoyu
    Deng, Bin
    An, Lin
    Chen, Wenliang
    Xu, Kexin
    OPTICAL DIAGNOSTICS AND SENSING VI, 2006, 6094
  • [23] Non-Invasive Glucose Measurement Using Spectrography In Near Infrared (NIR)
    Castro-Pimentel, Luis
    Tellez-Anguiano, Adriana
    Guerra-Alvarado, Osmar
    Hernandez-Franco, Kevin
    IEEE LATIN AMERICA TRANSACTIONS, 2019, 17 (11) : 1754 - 1760
  • [24] Non-Invasive Blood Glucose Monitoring using Near-Infrared Spectroscopy Based on Internet of Things using Machine Learning
    Manurung, Betty Elisabeth
    Munggaran, Hugi Reyhandani
    Ramadhan, Galih Fajar
    Koesoema, Allya Paramita
    PROCEEDINGS OF 2019 IEEE R10 HUMANITARIAN TECHNOLOGY CONFERENCE (IEEE R10 HTC 2019), 2019, : 5 - 11
  • [25] Non-Invasive Blood Glucose Monitoring Technology: A Review
    Tang, Liu
    Chang, Shwu Jen
    Chen, Ching-Jung
    Liu, Jen-Tsai
    SENSORS, 2020, 20 (23) : 1 - 32
  • [26] Non-invasive blood glucose monitoring technology in diabetes management: review
    Moses, Jeban Chandir
    Adibi, Sasan
    Wickramasinghe, Nilmini
    Nguyen, Lemai
    Angelova, Maia
    Islam, Sheikh Mohammed Shariful
    MHEALTH, 2024, 10 (01)
  • [27] Non-invasive impedance based continuous glucose monitoring system
    Talary, M. S.
    Dewarrat, F.
    Huber, D.
    Falco-Jonasson, L.
    Caduff, A.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 636 - +
  • [28] Non-invasive blood glucose measurement Application of near infrared optical measurement
    Anas, M. N.
    Syafirah, A.
    Norali, A. N.
    Normahira, M.
    2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT), 2012, : 258 - 261
  • [29] Research of transmissive near infrared spectroscopy for non-invasive blood glucose measurement
    Yang, Wenming
    Liao, Ningfang
    Li, Yasheng
    Shao, Liwei
    Huang, Dehuang
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VII, 2017, 0024
  • [30] Non-invasive monitoring of haemoglobin concentration in paediatric surgical patients using near-infrared spectroscopy
    Dullenkopf, A
    Lohmeyer, U
    Salgo, B
    Gerber, AC
    Weiss, M
    ANAESTHESIA, 2004, 59 (05) : 453 - 458