摘要
Regular monitoring of glucose concentration is essential and urgency, especially diabetics. However, those methods which involve finger puncturing are invasive, expensive as well as painful. Also, there are risks of infectious diseases using these techniques due to the contact of the needle on human skin. This paper proposed a non-invasive glucose monitoring system utilizing the near-infrared (NIR) light to measure the glucose concentration in the human blood. The designed system uses a 980 nm-wavelength NIR LED transmitting through D-glucose phantom samples, a photo-sensor for analyzing the transmitting optical parameters, a filter & an amplifier circuit, and a Nano Arduino microcontroller. For calculating the values of glucose concentration, the R programming with the methodology of the artificial neural network (ANN) was applied. This type of methodology is considered as one of the most useful technique in the world of data analysis and because it is adaptive, learns from the provided information and optimizes for better prediction outcomes. The ANN is used to predict the correlation equation between collected voltage and glucose concentration. The obtained glucose level is demonstrated directly on the system's screen or further sent to the user's mobile phone. The result obtained shows a correlation between the transmittance and the concentration of D-glucose solution. The correlation parameter of the technique is R-2 = 0.9957. Despite having the acceptable results, there are still some improvements that could be carried out for more accurate measurement (angle of the LED, a procedure of filtering and amplifying, usage of an optical instrument.). For further investigation and development, it is predicted that the result can be more accurate, precise and sensitivity as much as possible.
引用
收藏
页码:401 / 405
页数:5
相关论文
共 50 条
  • [1] Non-invasive Self Monitoring of Blood Glucose System Using Near-infrared Spectroscopy
    Yoshinari, Hiroki
    Ishizawa, Hiroaki
    Fukuda, Masaya
    Tokutake, Shota
    Koyama, Shouhei
    Miyauchi, Yuki
    2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2012, : 1852 - 1854
  • [2] Performance of a Non-Invasive System for Monitoring Blood Glucose Levels Based on Near-Infrared Spectroscopy Technology (Glucube®)
    Gomez-Peralta, Fernando
    Romero, Luis Gabriel Luque
    Puppo-Moreno, Antonio
    Riesgo, Jesus
    SENSORS, 2024, 24 (23)
  • [3] Evaluation of a near-infrared light ultrasound system as a non-invasive blood glucose monitoring device
    Meyhoefer, Svenja
    Wilms, Britta
    Ihling, Flavia
    Windjaeger, Anne
    Kalscheuer, Hannes
    Augustinov, Andrej
    Herrmann, Vera
    Lehnert, Hendrik
    Schmid, Sebastian M.
    DIABETES OBESITY & METABOLISM, 2020, 22 (04): : 694 - 698
  • [4] Clinical chemistry and near infrared spectroscopy: technology for non-invasive glucose monitoring
    Heise, HM
    Bittner, A
    Marbach, R
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, 1998, : 349 - 359
  • [5] Calibration break-through for near-infrared, non-invasive blood glucose monitoring
    Garg, SK
    Fischer, JS
    Ruchti, TL
    Blank, TB
    Lorenz, AD
    Monfre, SL
    DIABETES, 2002, 51 : A122 - A122
  • [6] Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 18 : 214 - 227
  • [7] Probeless non-invasive near-infrared spectroscopic bioprocess monitoring using microspectrometer technology
    Zimmerleiter, Robert
    Kager, Julian
    Nikzad-Langerodi, Ramin
    Berezhinskiy, Vladimir
    Westad, Frank
    Herwig, Christoph
    Brandstetter, Markus
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (09) : 2103 - 2109
  • [8] Probeless non-invasive near-infrared spectroscopic bioprocess monitoring using microspectrometer technology
    Robert Zimmerleiter
    Julian Kager
    Ramin Nikzad-Langerodi
    Vladimir Berezhinskiy
    Frank Westad
    Christoph Herwig
    Markus Brandstetter
    Analytical and Bioanalytical Chemistry, 2020, 412 : 2103 - 2109
  • [9] A Non-Invasive Blood Insulin and Glucose Monitoring System based on Near-Infrared Spectroscopy with Remote Data Logging
    Nandi, Bodhayan
    Mondal, Prosenjit
    Chowdhury, Shubhajit Roy
    2018 31ST IEEE INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS 2018), 2018, : 274 - 279
  • [10] Near-Infrared Light Emitting Diode Based Non-Invasive Glucose Detection System
    Lee, Seung Ho
    Kim, Min Seok
    Kim, Ok-Kyun
    Baik, Hyung-Hwan
    Kim, Ji-Hye
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2019, 19 (10) : 6187 - 6191