ESTIMATE OF BIRTH WEIGHT USING TWO- AND THREE-DIMENSIONAL ULTRASONOGRAPHY

被引:9
|
作者
Machado Nardozza, Luciano Marcondes [1 ]
Araujo Junior, Edward [1 ]
Vieira, Marcio Fragoso [1 ]
Rolo, Liliam Cristine [1 ]
Moron, Antonio Fernandes [1 ]
机构
[1] Univ Fed Sao Paulo, Escola Paulista Med, Dept Obstet, UNIFESP EPM, Sao Paulo, Brazil
来源
关键词
Fetal weight; Imaging; Three-Dimensional; Ultrasonography; PREDICTING FETAL WEIGHT; LIMB VOLUME; ULTRASOUND; GROWTH; ABDOMEN; THIGH; BODY; HEAD;
D O I
10.1590/S0104-42302010000200020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ESTIMATE OF BIRTH WEIGHT USING TWO- AND THREE-DIMENSIONAL ULTRASONOGRAPHY OBJECTIVE. Assess and compare accuracy of birth weight prediction using a combination of two-dimensional (abdominal circumference - AC and femur length - FL) and three-dimensional parameters (fetal arm -VolArm and thigh -VolTh volumes). METHODS. A cross sectional study was carried out involving 78 singleton, live, euploid fetuses without structural malformations born within 48 hours after ultrasonography. VolArm and VolTh were obtained by three-dimensional ultrasound using the multiplanar mode at 5 mm intervals. AC and FL were measured by two-dimensional ultrasound. Linear and polynomial regressions were calculated to determine the best formula to predict birth weight using VolArm, VolTh, CA and FL. ANOVA was used to compare errors in birth weight prediction using this formula and those obtained using the Shepard and Hadlock formulae. RESULTS. The best formula for prediction of birth weight was a simple linear regression (Weight = -1486.1 + 60.5AC + 140.57FL + 16.6 VolArm + 4.8VolTh), R2= 0.932. The error (E), absolute error (AE), percent error (PE) and absolute percent error (APE) for this new formula were 0 g, 0.2%, 112.2 g and 3.7%. This new formula had smaller E, AE, PE and APE than the Shepard formula and smaller AE and APE than Hadlock 's formula. CONCLUSION. A formula using VolArm, VolTh, AC and FL was more accurate for prediction of birth weight than formulae using only two-dimensional parameters. [Rev Assoc Med Bras 2010; 56(2): 204-8]
引用
收藏
页码:204 / 208
页数:5
相关论文
共 50 条
  • [21] AUDIOVISUAL SYNTHESIS OF POLISH USING TWO- AND THREE-DIMENSIONAL ANIMATION
    Belkowska, Joanna
    Glowienko, Anna
    Marasek, Krzysztof
    COMPUTER VISION AND GRAPHICS (ICCVG 2004), 2006, 32 : 1082 - 1087
  • [22] Fetal lung volumetry using two- and three-dimensional ultrasound
    Moeglin, D
    Talmant, C
    Duyme, M
    Lopez, AC
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 25 (02) : 119 - 127
  • [23] Using Clar sextets for two- and three-dimensional aromatic systems
    Balaban, Alexandru T.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2011, 13 (46) : 20649 - 20658
  • [24] Distinct neural correlates underlying two- and three-dimensional mental rotations using three-dimensional objects
    Kawamichi, Hiroaki
    Kikuchi, Yoshiaki
    Noriuchi, Madoka
    Senoo, Atsushi
    Ueno, Shoogo
    BRAIN RESEARCH, 2007, 1144 : 117 - 126
  • [25] Three-Dimensional Leaf Edge Reconstruction Combining Two- and Three-Dimensional Approaches
    Murata, Hidekazu
    Noshita, Koji
    PLANT PHENOMICS, 2024, 6
  • [26] Crossover from two- to three-dimensional turbulence
    Smith, LM
    Chasnov, JR
    Waleffe, F
    PHYSICAL REVIEW LETTERS, 1996, 77 (12) : 2467 - 2470
  • [27] Lanthanide oxalatophosphonates with two- and three-dimensional structures
    Yang, Ting-Hai
    Cao, Deng-Ke
    Li, Yi-Zhi
    Zheng, Li-Min
    JOURNAL OF SOLID STATE CHEMISTRY, 2010, 183 (05) : 1159 - 1164
  • [28] Excitons consisting of two- and three-dimensional particles
    Piao, ZS
    Nakayama, M
    Nishimura, H
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1997, 66 (05) : 1567 - 1568
  • [29] Topological insulator: Both two- and three-dimensional
    He, Ke
    FRONTIERS OF PHYSICS, 2012, 7 (02) : 148 - 149
  • [30] Topological insulator: Both two- and three-dimensional
    Ke He
    Frontiers of Physics, 2012, 7 : 148 - 149