NEMA NU-4 2008 performance evaluation of Xtrim-PET: A prototype SiPM-based preclinical scanner

被引:25
作者
Amirrashedi, Mahsa [1 ,2 ]
Sarkar, Saeed [1 ,2 ]
Ghafarian, Pardis [3 ,4 ]
Shahraki, Reza Hashemi [1 ,2 ]
Geramifar, Parham [5 ]
Zaidi, Habib [6 ,7 ,8 ,9 ]
Ay, Mohammad Reza [1 ,2 ]
机构
[1] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Chron Resp Dis Res Ctr, NRITLD, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Masih Daneshvari Hosp, PET CT & Cyclotron Ctr, Tehran, Iran
[5] Univ Tehran Med Sci, Shariati Hosp, Res Ctr Nucl Med, Tehran, Iran
[6] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[7] Univ Geneva, Neuroctr, CH-1205 Geneva, Switzerland
[8] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
[9] Univ Southern Denmark, Dept Nucl Med, DK-500 Odense, Denmark
关键词
detectors; NEMA standard; performance evaluation; PET; small animal imaging; PET/MRI; INSERT; ALGORITHMS; SYSTEM; MRI;
D O I
10.1002/mp.13785
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Xtrim-PET is a newly designed Silicon Photomultipliers (SiPMs)-based prototype PET scanner dedicated for small laboratory animal imaging. We present the performance evaluation of the Xtrim-PET scanner following NEMA NU-4 2008 standards to help optimizing scanning protocols which can be achieved through standard and reliable system performance characterization. Methods The performance assessment was conducted according to the National Electrical Manufacturers Association (NEMA) NU-4 2008 standards in terms of spatial resolution, sensitivity, counting rate performance, scatter fraction and image quality. The in vivo imaging capability of the scanner is also showcased through scanning a normal mouse injected with F-18-FDG. Furthermore, the performance characteristics of the developed scanner are compared with commercially available systems and current prototypes. Results The volumetric spatial resolution at 5 mm radial offset from the central axis of the scanner is 6.81 mu l, whereas a peak absolute sensitivity of 2.99% was achieved using a 250-650 keV energy window and a 10 ns timing window. The peak noise-equivalent count rate (NECR) using a mouse-like phantom is 113.18 kcps at 0.34 KBq/cc with 12.5% scatter fraction, whereas the NECR peaked at 82.76 kcps for an activity concentration level of 0.048 KBq/cc with a scatter fraction of 25.8% for rat-like phantom. An excellent uniformity (3.8%) was obtained using NEMA image quality phantom. Recovery coefficients of 90%, 86%, 68%, 40% and 12% were calculated for rod diameters of 5, 4, 3, 2 and 1 mm, respectively. Spill-over ratios for air-filled and water-filled chambers were 35% and 25% without applying any correction for attenuation and Compton scattering effects. Conclusion Our findings revealed that beyond compactness, lightweight, easy installation and good energy resolution, the Xtrim-PET prototype presents a reasonable performance making it suitable for preclinical molecular imaging-based research.
引用
收藏
页码:4816 / 4825
页数:10
相关论文
共 44 条
  • [1] Algorithms for calculating detector efficiency normalization coefficients for true coincidences in 3D PET
    Badawi, RD
    Lodge, MA
    Marsden, PK
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (01) : 189 - 205
  • [2] Initial performance evaluation of a high resolution Albira small animal positron emission tomography scanner with monolithic crystals and depth-of-interaction encoding from a user's perspective
    Balcerzyk, Marcin
    Kontaxakis, George
    Delgado, Mercedes
    Garcia-Garcia, Luis
    Correcher, Carlos
    Gonzalez, Antonio J.
    Gonzalez, Aurora
    Rubio, Jose L.
    Benlloch, Jose M.
    Pozo, Miguel A.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (10)
  • [3] NEMA NU-4 Performance Evaluation of the IRIS PET/CT Preclinical Scanner
    Belcari N.
    Camarlinghi N.
    Ferretti S.
    Iozzo P.
    Panetta D.
    Salvadori P.A.
    Sportelli G.
    Del Guerra A.
    [J]. IEEE Transactions on Radiation and Plasma Medical Sciences, 2017, 1 (04): : 301 - 309
  • [4] Bergeron M, 2009, IEEE NUCL SCI S NSS
  • [5] Hybrid Imaging: Instrumentation and Data Processing
    Cal-Gonzalez, Jacobo
    Rausch, Ivo
    Sundar, Lalith K. Shiyam
    Lassen, Martin L.
    Muzik, Otto
    Moser, Ewald
    Papp, Laszlo
    Beyer, Thomas
    [J]. FRONTIERS IN PHYSICS, 2018, 6
  • [6] NEMA NU 4-2008 Performance Measurements of Two Commercial Small-Animal PET Scanners: ClearPET and rPET-1
    Canadas, Mario
    Embid, Miguel
    Lage, Eduardo
    Desco, Manuel
    Jose Vaquero, Juan
    Manuel Perez, Jose
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 58 - 65
  • [7] DAUBEWITHERSPOON ME, 1987, J NUCL MED, V28, P1717
  • [8] Exact and approximate rebinning algorithms for 3-D PET data
    Defrise, M
    Kinahan, PE
    Townsend, DW
    Michel, C
    Sibomana, M
    Newport, DF
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 145 - 158
  • [9] Elhami E, 2011, IEEE NUCL SCI S
  • [10] First Results From a High-Resolution Small Animal SiPM PET Insert for PET/MR Imaging at 7T
    Goertzen, Andrew L.
    Stortz, Greg
    Thiessen, Jonathan D.
    Bishop, Daryl
    Khan, Muhammad Salman
    Kozlowski, Piotr
    Retiere, Fabrice
    Schellenberg, Graham
    Shams, Ehsan
    Sossi, Vesna
    Thompson, Christopher J.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (05) : 2424 - 2433