Influence of temporal regularization and radial undersampling factor on compressed sensing reconstruction in dynamic contrast enhanced MRI of the breast

被引:34
作者
Kim, Sungheon G. [1 ,2 ,3 ]
Feng, Li [1 ,2 ,3 ,4 ]
Grimm, Robert [5 ,6 ]
Freed, Melanie [1 ,2 ,3 ]
Block, Kai Tobias [1 ,2 ,3 ]
Sodickson, Daniel K. [1 ,2 ,3 ]
Moy, Linda [1 ,2 ,3 ]
Otazo, Ricardo [1 ,2 ,3 ]
机构
[1] NYU, Sch Med, Dept Radiol, 660 First Ave,Room 413, New York, NY 10016 USA
[2] NYU, Sch Med, Ctr Adv Imaging & Innovat & Res CAI2R, New York, NY USA
[3] NYU, Sch Med, Bernard & Irene Schwartz Ctr Biomed Imaging, New York, NY USA
[4] NYU, Sch Med, Sackler Inst Grad Biomed Sci, New York, NY USA
[5] FAU Erlangen Nuremberg, Pattern Recognit Lab, Erlangen, Germany
[6] Siemens AG Healthcare MR, Erlangen, Germany
基金
美国国家卫生研究院;
关键词
compressed sensing; parallel imaging; temporal sparsity; radial undersampling; golden-angle; DCE-MRI; breast cancer; iGRASP; CONDITIONAL MUTUAL INFORMATION; MEDICAL IMAGE REGISTRATION; T SPARSE-SENSE; QUALITY ASSESSMENT; COMBINATION; MAXIMIZATION; SIMILARITY;
D O I
10.1002/jmri.24961
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundTo evaluate the influence of temporal sparsity regularization and radial undersampling on compressed sensing reconstruction of dynamic contrast-enhanced (DCE) MRI, using the iterative Golden-angle RAdial Sparse Parallel (iGRASP) MRI technique in the setting of breast cancer evaluation. MethodsDCE-MRI examinations of the breast (n=7) were conducted using iGRASP at 3 Tesla. Images were reconstructed with five different radial undersampling schemes corresponding to temporal resolutions between 2 and 13.4 s/frame and with four different weights for temporal sparsity regularization (=0.1, 0.5, 2, and 6 times of noise level). Image similarity to time-averaged reference images was assessed by two breast radiologists and using quantitative metrics. Temporal similarity was measured in terms of wash-in slope and contrast kinetic model parameters. ResultsiGRASP images reconstructed with =2 and 5.1 s/frame had significantly (P<0.05) higher similarity to time-averaged reference images than the images with other reconstruction parameters (mutual information (MI) >5%), in agreement with the assessment of two breast radiologists. Higher undersampling (temporal resolution<5.1 s/frame) required stronger temporal sparsity regularization (2) to remove streaking aliasing artifacts (MI>23% between =2 and 0.5). The difference between the kinetic-model transfer rates of benign and malignant groups decreased as temporal resolution decreased (82% between 2 and 13.4 s/frame). ConclusionThis study demonstrates objective spatial and temporal similarity measures can be used to assess the influence of sparsity constraint and undersampling in compressed sensing DCE-MRI and also shows that the iGRASP method provides the flexibility of optimizing these reconstruction parameters in the postprocessing stage using the same acquired data.
引用
收藏
页码:261 / 269
页数:9
相关论文
共 37 条
[1]   Digital watermarking of low bit-rate advanced simple profile MPEG-4 compressed video [J].
Alattar, AM ;
Lin, ET ;
Celik, MU .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 2003, 13 (08) :787-800
[2]  
Ashburner J, 1999, HUM BRAIN MAPP, V7, P254, DOI 10.1002/(SICI)1097-0193(1999)7:4<254::AID-HBM4>3.0.CO
[3]  
2-G
[4]  
Block K, 2011, P 19 ANN M ISMRM MON
[5]   Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint [J].
Block, Kai Tobias ;
Uecker, Martin ;
Frahm, Jens .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1086-1098
[6]   Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information [J].
Candès, EJ ;
Romberg, J ;
Tao, T .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) :489-509
[7]  
Cashen TA, 2006, AM J NEURORADIOL, V27, P822
[8]   The influence of radial undersampling schemes on compressed sensing reconstruction in breast MRI [J].
Chan, Rachel W. ;
Ramsay, Elizabeth A. ;
Cheung, Edward Y. ;
Plewes, Donald B. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) :363-377
[9]   Free-Breathing Contrast-Enhanced Multiphase MRI of the Liver Using a Combination of Compressed Sensing, Parallel Imaging, and Golden-Angle Radial Sampling [J].
Chandarana, Hersh ;
Feng, Li ;
Block, Tobias K. ;
Rosenkrantz, Andrew B. ;
Lim, Ruth P. ;
Babb, James S. ;
Sodickson, Daniel K. ;
Otazo, Ricardo .
INVESTIGATIVE RADIOLOGY, 2013, 48 (01) :10-16
[10]   Quality criteria benchmark for hyperspectral imagery [J].
Christophe, E ;
Léger, D ;
Mailhes, C .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2005, 43 (09) :2103-2114