Chronic and adjustable pulmonary artery banding

被引:20
作者
Leeuwenburgh, BPJ
Schoof, PH
Steendijk, P
Baan, J
Mooi, WJ
Helbing, WA
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, Cardiac Physiol Lab, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Pediat, NL-2300 RC Leiden, Netherlands
[3] Leiden Univ, Med Ctr, Dept Cardiothorac Surg, NL-2300 RC Leiden, Netherlands
[4] Netherlands Canc Inst, Dept Pathol, NL-1066 CX Amsterdam, Netherlands
[5] Erasmus Med Ctr, Sophia Childrens Hosp, Dept Pediat Pediat Cardiol, Rotterdam, Netherlands
关键词
D O I
10.1067/mtc.2003.23
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Banding of the pulmonary artery might be required to prevent pulmonary vascular damage in patients with increased pulmonary artery flow and to retrain the left ventricle in preparation for an arterial switch operation in patients with congenitally corrected transposition of the great arteries. Readjustment of the pulmonary artery band might be required in the postoperative period. In this study we aimed to test the feasibility of a novel device for bidirectionally adjustable pulmonary artery constriction. Methods: A hydraulic main pulmonary artery occluder was implanted in lambs and gradually inflated to create right ventricular pressure overload at a systemic (aortic) level. During the following period (up to 12 weeks), this pressure overload was monitored by measuring aortic and right ventricular pressures by means of implanted subcutaneous reservoirs. If required to maintain the right ventricular pressure overload at a systemic level in the growing animals, the occluder was deflated through a third subcutaneous reservoir. Results: After the banding period (average of 64 8 days), the main pulmonary artery cuff could still be adjusted, and the animals showed no clinical signs of heart failure. Histologic analysis of the pulmonary artery showed extensive fibrosis, a giant cell response around the device, and small areas of tissue necrosis; complete transmural necrosis was not detected. Conclusions: This device allows adjustment of the pulmonary artery cuff in a precise manner over a prolonged period of time without surgical reintervention. Potentially, the device might have applications for clinical use in children with congenital heart disease.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 24 条
[1]  
AHMADI A, 1995, ANN THORAC SURG, V60, P520
[2]  
ALBUS RA, 1984, J THORAC CARDIOV SUR, V88, P645
[3]   EFFICACY OF PULMONARY-ARTERY BANDING IN THE PREVENTION OF PULMONARY VASCULAR OBSTRUCTIVE DISEASE [J].
BOROWSKI, A ;
ZEUCHNER, M ;
SCHICKENDANTZ, S ;
KORB, H .
CARDIOLOGY, 1994, 85 (3-4) :207-215
[4]   Experience with an adjustable pulmonary artery banding device in two cases:: Initial success -: Midterm failure [J].
Däbritz, S ;
Sachweh, J ;
Tiete, A ;
Engelhardt, W ;
von Bernuth, G ;
Messmer, BJ .
THORACIC AND CARDIOVASCULAR SURGEON, 1999, 47 (01) :51-52
[5]   Right ventricular regional function using MR tagging: Normals versus chronic pulmonary hypertension [J].
Fayad, ZA ;
Ferrari, VA ;
Kraitchman, DL ;
Young, AA ;
Palevsky, HI ;
Bloomgarden, DC ;
Axel, L .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (01) :116-123
[6]   Ventriculo-arterial discordance: switching the morphologically left ventricle into the systemic circulation after 3 months of age [J].
Helvind, MH ;
McCarthy, JF ;
Imamura, M ;
Prieto, L ;
Sarris, GE ;
Drummond-Webb, JJ ;
Mee, RBB .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 14 (02) :173-178
[7]  
Henry J, 1973, Ann Thorac Surg, V15, P109
[8]  
HIGASHIDATE M, 1989, J THORAC CARDIOV SUR, V97, P864
[9]   PULMONARY-ARTERY BANDING - ANALYSIS OF A 25-YEAR EXPERIENCE [J].
HOROWITZ, MD ;
CULPEPPER, WS ;
WILLIAMS, LC ;
SUNDGAARDRIISE, K ;
OCHSNER, JL .
ANNALS OF THORACIC SURGERY, 1989, 48 (03) :444-450
[10]  
ILBAWI MN, 1987, J THORAC CARDIOV SUR, V94, P87