Sampling for PPCPs in Wastewater Systems: Comparison of Different Sampling Modes and Optimization Strategies

被引:295
作者
Ort, Christoph [1 ]
Lawrence, Michael G. [1 ]
Reungoat, Julien [1 ]
Mueller, Jochen F. [2 ]
机构
[1] Univ Queensland, Adv Water Management Ctr, Brisbane, Qld 4072, Australia
[2] Univ Queensland, Natl Res Ctr Environm Toxicol, Coopers Plains, Qld 4108, Australia
基金
瑞士国家科学基金会; 美国国家科学基金会;
关键词
SEWER SYSTEMS; PHARMACEUTICALS; SOLIDS;
D O I
10.1021/es100778d
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study was to assess uncertainties associated with different sampling modes when evaluating loads of pharmaceuticals and personal care products (PPCPs) in sewers and influents to sewage treatment plants (STPs). The study demonstrates that sampling uncertainty can range from "not significant" to "far greater than the uncertainty due to chemical analysis", which is site- and compound-specific and depends on the (in)accuracy of the analytical method Conventional sampling devices operated in common time- or flow-proportional sampling modes, and applying traditional sampling intervals of 30 min or longer can result in the collection of nonrepresentative samples At the influent of a STP, wastewater may appear as a continuous stream, but it is actually composed of a number of intermittently discharged, individual wastewater packets from household appliances, industries, or subcatchments in pressurized sewer systems. The resulting heterogeneity can cause significant short-term variations of pollutant loads We present different experimental results and a modeling approach showing that the magnitude of sampling uncertainty depends mainly on the number of pollutant peaks and the sampling frequency, sampling intervals of 5 min or shorter may be required to properly account for temporal PPCP variations in influents of STPs A representative sample is a prerequisite for providing meaningful analytical results and cannot be compensated with a large number of samples, accurate chemical analysis, or sophisticated statistical evaluation This study highlights that generalizing from one case to another is difficult and hence a careful systems analysis of the catchment under investigation, or precautionary choice for a sophisticated sampling mode, is necessary to prove reproducibility.
引用
收藏
页码:6289 / 6296
页数:8
相关论文
共 19 条
[1]   Anthropogenic origin of positive gadolinium anomalies in river waters [J].
Bau, M ;
Dulski, P .
EARTH AND PLANETARY SCIENCE LETTERS, 1996, 143 (1-4) :245-255
[2]   Measuring solids concentration in stormwater runoff: Comparison of analytical methods [J].
Clark, Shirley E. ;
Siu, Christina Y. S. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2008, 42 (02) :511-516
[3]  
Clesceri L., 1998, STANDARD METHODS EXA, V20
[4]   ENVIRONMENTAL FOOTPRINT OF PHARMACEUTICALS: THE SIGNIFICANCE OF FACTORS BEYOND DIRECT EXCRETION TO SEWERS [J].
Daughton, Christian G. ;
Ruhoy, Ilene S. .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2009, 28 (12) :2495-2521
[5]  
Gy P, 1998, Sampling for Analytical Purposes
[6]  
ISO, 1980, 56671 ISO
[7]  
ISO, 1992, ISO 5667-10
[8]   Suspended solids within sewers: an experimental study [J].
Larrarte, Frederiqu .
ENVIRONMENTAL FLUID MECHANICS, 2008, 8 (03) :249-261
[9]  
LAWRENCE MG, CHEMOSPHERE IN PRESS, DOI DOI 10.1016/J.CHEMOSPHERE.2010.05.001
[10]   Direct quantification of rare earth element concentrations in natural waters by ICP-MS [J].
Lawrence, Michael G. ;
Greig, Alan ;
Collerson, Kenneth D. ;
Kamber, Balz S. .
APPLIED GEOCHEMISTRY, 2006, 21 (05) :839-848